background image

3

FXHQ-MVJU

EDUS39-600A-F5

2. 

Specifications

Ceiling suspended type

Model

FXHQ12MVJU

FXHQ24MVJU

Power supply

1 phase, 60 Hz, 208/230 V

1 phase, 60 Hz, 208/230 V

H

1, 

H

3 Cooling capacity

Btu/h

12,000

24,000

H

2, 

H

3 Heating capacity

Btu/h

13,500

27,000

Casing / Color

White (10Y9/0.5)

White (10Y9/0.5)

Dimensions: (H

 

× W

 

× D)

in.

7-11/16

 

× 37-13/16

 

× 26-3/4

7-11/16

 

× 55-1/8

 

× 26-3/4

Coil (cross fin 

coil)

Rows

 

× Stages

 

× FPI

2

 

× 12

 

× 15

3

 

× 12

 

× 15

Face area

ft²

1.96

3.15

Fan

Model

3D12K1AA1

3D12K2AA1

Type

Sirocco fan

Sirocco fan

Motor output

W

62

130

Airflow rate (H/L)

cfm

410/340

710/600

Drive

Direct drive

Direct drive

Temperature control

Microprocessor thermostat for cooling and 

heating

Microprocessor thermostat for cooling and 

heating

Sound absorbing thermal insulation material

Glass wool

Glass wool

Air filter

Resin net (with mold resistant)

Resin net (with mold resistant)

H

4 Sound pressure level (reference 

data) (H/L)

dBA

42/38

44/42

Weight

lbs

55

80

Piping 

connections

Liquid pipes

in.

f

1/4 (flare connection)

f

3/8 (flare connection)

Gas pipes

in.

f

1/2 (flare connection)

f

5/8 (flare connection)

Drain pipe

in.

VP20 (external dia. 1, internal dia. 3/4)

VP20 (external dia. 1, internal dia. 3/4)

Safety devices

Fuse, Thermal protector for fan motor

Fuse, Thermal protector for fan motor

Refrigerant control

Electronic expansion valve

Electronic expansion valve

Connectable outdoor unit

R410A 

VRV

 series

R410A 

VRV

 series

Standard accessories

Operation manual, Installation manual, Drain 

hose, Paper pattern for installation, Clamp metal, 

Insulation for fitting, Clamps, Washers

Operation manual, Installation manual, Drain 

hose, Paper pattern for installation, Clamp metal, 

Insulation for fitting, Clamps, Washers

Note:

H

1.  Nominal cooling capacities are based on the following conditions: 

 

Return air temperature: 80°FDB, 67°FWB

 

Outdoor temperature: 95°FDB 

 

Equivalent refrigerant piping length: 25 ft (horizontal)

H

2.  Nominal heating capacities are based on the following conditions:

 

Return air temperature: 70°FDB. 

 

Outdoor temperature: 47°FDB, 43°FWB

 

Equivalent refrigerant piping length: 25 ft (horizontal)

H

3.  Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.

H

4.  Anechoic chamber conversion value, measured under JIS conditions. During actual operation, 

 

these values may be higher as a result of ambient conditions.

C: 4D049326

Summary of Contents for FXHQ-MVJU

Page 1: ...Ceiling Suspended Type FXHQ MVJU EDUS39 600A F5 202103 Engineering Data 60 Hz...

Page 2: ......

Page 3: ...Setting 12 8 Capacity Tables 13 8 1 Cooling Capacity at Te 43 F 6 C 13 8 2 Heating Capacity 13 8 3 Correction Factor for Cooling Capacity at Te 48 F 9 C 13 9 Air Velocity and Temperature Distributions...

Page 4: ...n Wide air discharge outlet distributes a comfortable airflow throughout the space with throw of up to 25 ft Innovative stream fan technology allows for operating sound level as low as 38 dB A Simple...

Page 5: ...tion Drain pipe in VP20 external dia 1 internal dia 3 4 VP20 external dia 1 internal dia 3 4 Safety devices Fuse Thermal protector for fan motor Fuse Thermal protector for fan motor Refrigerant contro...

Page 6: ...nal dia 1 internal dia 3 4 Safety devices Fuse Thermal protector for fan motor Refrigerant control Electronic expansion valve Connectable outdoor unit R410A VRV series Standard accessories Operation m...

Page 7: ...5 FXHQ MVJU EDUS39 600A F5 3 Dimensions FXHQ12MVJU 3D049330A Unit in...

Page 8: ...6 FXHQ MVJU EDUS39 600A F5 FXHQ24MVJU 3D049331A Unit in...

Page 9: ...7 FXHQ MVJU EDUS39 600A F5 FXHQ36MVJU 3D049332B Unit in...

Page 10: ...8 FXHQ MVJU EDUS39 600A F5 4 Piping Diagrams FXHQ12 36MVJU Unit in Model Gas Liquid FXHQ12MVJU f1 2 f1 4 FXHQ24 36MVJU f5 8 f3 8 4D024460P...

Page 11: ...HE ATTACHED INSTRUCTION MANUAL 4 X23A IS CONNECTED WHEN THE WIRELESS REMOTE CONTROLLER KIT IS BEING USED 5 WHEN CONNECTING THE INPUT WIRES FROM OUTSIDE FORCED OFF OR ON OFF CONTROL OPERATION CAN BE SE...

Page 12: ...AP T1R TRANSFORMER 208 230 V 25 V V1TR TRIAC X1M TERMINAL BLOCK POWER X2M TERMINAL BLOCK CONTROL Y1E ELECTRONIC EXPANSION VALVE RECEIVER DISPLAY UNIT ATTACHED TO WIRELESS REMOTE CONTROLLER A2P PRINTED...

Page 13: ...Ampacity A MOP Maximum Overcurrent Protective Device A KW Fan Motor Rated Output kW FLA Full Load Ampacity A IFM Indoor Fan Motor SCCR Short Circuit Current Rating Note 1 Voltage range Units are suit...

Page 14: ...Device Setting Model FXHQ12MVJU FXHQ24MVJU FXHQ36MVJU Printed circuit board fuse 250 V 5 A 250 V 5 A 250 V 5 A Fan motor thermal fuse F Fan motor thermal protector F OFF 266 9 ON 176 36 OFF 266 9 ON 1...

Page 15: ...23 9 TC TC TC TC TC TC MBH MBH MBH MBH MBH MBH FXHQ12MVJU 14 9 14 7 14 0 13 5 13 0 12 3 FXHQ24MVJU 29 7 29 5 28 0 27 0 26 0 24 5 FXHQ36MVJU 44 6 44 2 42 0 40 0 39 0 36 8 TC Total capacity MBH Note 1 T...

Page 16: ...14 FXHQ MVJU EDUS39 600A F5 9 Air Velocity and Temperature Distributions Reference Data 9 1 Cooling Mode FXHQ12MVJU Cooling mode AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C 3D052938...

Page 17: ...15 FXHQ MVJU EDUS39 600A F5 FXHQ24MVJU Cooling mode C 3D052939 AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS...

Page 18: ...16 FXHQ MVJU EDUS39 600A F5 FXHQ36MVJU Cooling mode AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C 3D052940...

Page 19: ...17 FXHQ MVJU EDUS39 600A F5 9 2 Heating Mode FXHQ12MVJU Heating mode AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C 3D052938...

Page 20: ...18 FXHQ MVJU EDUS39 600A F5 FXHQ24MVJU Heating mode AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C 3D052939...

Page 21: ...19 FXHQ MVJU EDUS39 600A F5 FXHQ36MVJU Heating mode AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C 3D052940...

Page 22: ...0A F5 10 Sound Levels Reference Data 10 1 Overall n Ceiling suspended type Note Operation noise differs with operation and ambient conditions dBA Model 208 230 V 60 Hz H L FXHQ12MVJU 42 38 FXHQ24MVJU...

Page 23: ...21 FXHQ MVJU EDUS39 600A F5 10 2 Octave Band Level 208 230 V 60 Hz FXHQ12MVJU FXHQ24MVJU C 4D052512 C 4D052513 FXHQ36MVJU C 4D052514...

Page 24: ...ssories 11 1 Optional Accessories for Unit Option FXHQ12MVJU FXHQ24MVJU FXHQ36MVJU Replacement long life filter resin net KAFJ501D56 KAFJ501D112 KAFJ501D160 L type piping kit for upward direction KHFP...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...or explosion Use only those parts and accessories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessori...