FXHQ-MVJU

EDUS39-600A-F5

8. 

Capacity Tables

8.1 

Cooling Capacity at Te: 43°F (6°C)

Model

Indoor air temp. °FWB (°CWB) (Te: 43°F (6°C))

61 (16.1)

64 (17.8)

67 (19.4)

70 (21.1)

72 (22.2)

75 (23.9)

TC

SHC

TC

SHC

TC

SHC

TC

SHC

TC

SHC

TC

SHC

MBH

MBH

MBH

MBH

MBH

MBH

MBH

MBH

MBH

MBH

MBH

MBH

FXHQ12MVJU

9.5

8.5

10.7

8.8

12.0

9.4

12.7

9.4 

12.9

9.3 

13.1

8.9 

FXHQ24MVJU

18.9

15.3 

21.5

16.6 

24.0

17.1 

25.5

17.4 

25.8

17.1 

26.3

16.2 

FXHQ36MVJU

28.4

21.8 

32.2

23.9 

36.0

25.1 

38.2

25.3 

38.7

24.6 

39.4

23.7 

TC:   Total capacity: MBH

SHC:  Sensible heat capacity: MBH

Note:

1. These capacity tables can be used when selecting a 

VRV

 indoor unit. The actual capacity of the 

VRV

 system depends on factors such as the 

selected model of outdoor units, outdoor air temperature and piping length. Please confirm that the corrected capacity of the 

VRV

 system satisfies 

the required heat load.

2. 

 shows rated condition.

8.2 

Heating Capacity

Model

Indoor air temp. °FDB (°CDB) (Tc: 115°F (46°C))

62 (16.7)

65 (18.3)

68 (20.0)

70 (21.1)

72 (22.2)

75 (23.9)

TC

TC

TC

TC

TC

TC

MBH

MBH

MBH

MBH

MBH

MBH

FXHQ12MVJU

14.9

14.7

14.0

13.5

13.0

12.3

FXHQ24MVJU

29.7

29.5

28.0

27.0

26.0

24.5

FXHQ36MVJU

44.6

44.2

42.0

40.0

39.0

36.8

TC: Total capacity: MBH

Note:

1. These capacity tables can be used when selecting a 

VRV

 indoor unit. The actual capacity of the 

VRV

 system depends on factors such as the 

selected model of outdoor units, outdoor air temperature and piping length. Please confirm that the corrected capacity of the 

VRV

 system satisfies 

the required heat load.

2. 

 shows rated condition.

8.3  Correction Factor for Cooling Capacity at Te: 48°F (9°C)

Refer to the correction factor table below when a mini-split indoor unit

 

is connected to a 

VRV

 Heat Pump system using a Branch Port box.

Model

Indoor air temp. °FWB (°CWB) (Te: 48°F (9°C))

57 (13.9)

61 (16.1)

64 (17.8)

67 (19.4)

70 (21.1)

72 (22.2)

75 (23.9)

TC

SHF

TC

SHF

TC

SHF

TC

SHF

TC

SHF

TC

SHF

TC

SHF

FXHQ12MVJU

0.71

1.09

0.69

1.18

0.74

1.13

0.78

1.09

0.81

1.07

0.82

1.05

0.84

1.04

FXHQ24MVJU

0.69

1.12

0.70

1.17

0.74

1.13

0.78

1.09

0.81

1.07

0.82

1.06

0.84

1.06

FXHQ36MVJU

0.69

1.12

0.70

1.17

0.75

1.12

0.79

1.08

0.82

1.06

0.83

1.06

0.85

1.06

TC:   Total capacity

SHF:  Sensible heat factor

CA14A307C

Summary of Contents for FXHQ-MVJU

Page 1: ...Ceiling Suspended Type FXHQ MVJU EDUS39 600A F5 202103 Engineering Data 60 Hz...

Page 2: ......

Page 3: ...Setting 12 8 Capacity Tables 13 8 1 Cooling Capacity at Te 43 F 6 C 13 8 2 Heating Capacity 13 8 3 Correction Factor for Cooling Capacity at Te 48 F 9 C 13 9 Air Velocity and Temperature Distributions...

Page 4: ...n Wide air discharge outlet distributes a comfortable airflow throughout the space with throw of up to 25 ft Innovative stream fan technology allows for operating sound level as low as 38 dB A Simple...

Page 5: ...tion Drain pipe in VP20 external dia 1 internal dia 3 4 VP20 external dia 1 internal dia 3 4 Safety devices Fuse Thermal protector for fan motor Fuse Thermal protector for fan motor Refrigerant contro...

Page 6: ...nal dia 1 internal dia 3 4 Safety devices Fuse Thermal protector for fan motor Refrigerant control Electronic expansion valve Connectable outdoor unit R410A VRV series Standard accessories Operation m...

Page 7: ...5 FXHQ MVJU EDUS39 600A F5 3 Dimensions FXHQ12MVJU 3D049330A Unit in...

Page 8: ...6 FXHQ MVJU EDUS39 600A F5 FXHQ24MVJU 3D049331A Unit in...

Page 9: ...7 FXHQ MVJU EDUS39 600A F5 FXHQ36MVJU 3D049332B Unit in...

Page 10: ...8 FXHQ MVJU EDUS39 600A F5 4 Piping Diagrams FXHQ12 36MVJU Unit in Model Gas Liquid FXHQ12MVJU f1 2 f1 4 FXHQ24 36MVJU f5 8 f3 8 4D024460P...

Page 11: ...HE ATTACHED INSTRUCTION MANUAL 4 X23A IS CONNECTED WHEN THE WIRELESS REMOTE CONTROLLER KIT IS BEING USED 5 WHEN CONNECTING THE INPUT WIRES FROM OUTSIDE FORCED OFF OR ON OFF CONTROL OPERATION CAN BE SE...

Page 12: ...AP T1R TRANSFORMER 208 230 V 25 V V1TR TRIAC X1M TERMINAL BLOCK POWER X2M TERMINAL BLOCK CONTROL Y1E ELECTRONIC EXPANSION VALVE RECEIVER DISPLAY UNIT ATTACHED TO WIRELESS REMOTE CONTROLLER A2P PRINTED...

Page 13: ...Ampacity A MOP Maximum Overcurrent Protective Device A KW Fan Motor Rated Output kW FLA Full Load Ampacity A IFM Indoor Fan Motor SCCR Short Circuit Current Rating Note 1 Voltage range Units are suit...

Page 14: ...Device Setting Model FXHQ12MVJU FXHQ24MVJU FXHQ36MVJU Printed circuit board fuse 250 V 5 A 250 V 5 A 250 V 5 A Fan motor thermal fuse F Fan motor thermal protector F OFF 266 9 ON 176 36 OFF 266 9 ON 1...

Page 15: ...23 9 TC TC TC TC TC TC MBH MBH MBH MBH MBH MBH FXHQ12MVJU 14 9 14 7 14 0 13 5 13 0 12 3 FXHQ24MVJU 29 7 29 5 28 0 27 0 26 0 24 5 FXHQ36MVJU 44 6 44 2 42 0 40 0 39 0 36 8 TC Total capacity MBH Note 1 T...

Page 16: ...14 FXHQ MVJU EDUS39 600A F5 9 Air Velocity and Temperature Distributions Reference Data 9 1 Cooling Mode FXHQ12MVJU Cooling mode AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C 3D052938...

Page 17: ...15 FXHQ MVJU EDUS39 600A F5 FXHQ24MVJU Cooling mode C 3D052939 AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS...

Page 18: ...16 FXHQ MVJU EDUS39 600A F5 FXHQ36MVJU Cooling mode AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C 3D052940...

Page 19: ...17 FXHQ MVJU EDUS39 600A F5 9 2 Heating Mode FXHQ12MVJU Heating mode AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C 3D052938...

Page 20: ...18 FXHQ MVJU EDUS39 600A F5 FXHQ24MVJU Heating mode AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C 3D052939...

Page 21: ...19 FXHQ MVJU EDUS39 600A F5 FXHQ36MVJU Heating mode AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C 3D052940...

Page 22: ...0A F5 10 Sound Levels Reference Data 10 1 Overall n Ceiling suspended type Note Operation noise differs with operation and ambient conditions dBA Model 208 230 V 60 Hz H L FXHQ12MVJU 42 38 FXHQ24MVJU...

Page 23: ...21 FXHQ MVJU EDUS39 600A F5 10 2 Octave Band Level 208 230 V 60 Hz FXHQ12MVJU FXHQ24MVJU C 4D052512 C 4D052513 FXHQ36MVJU C 4D052514...

Page 24: ...ssories 11 1 Optional Accessories for Unit Option FXHQ12MVJU FXHQ24MVJU FXHQ36MVJU Replacement long life filter resin net KAFJ501D56 KAFJ501D112 KAFJ501D160 L type piping kit for upward direction KHFP...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...or explosion Use only those parts and accessories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessori...

Reviews: