![background image](http://html1.mh-extra.com/html/daikin/fvq71bv/fvq71bv_installation-manual_4703920012.webp)
10
English
7. SEPARATE INSTALLATION OF THE CONTROL PANEL
• For this unit, remote controller (operation part) attached to the control panel can be installed separately by
using the field supplied remote controller cord.
Refer to section of ELECTRIC WIRING WORK (p. 12) for specifications of remote controller cord.
1. Detach the terminal box lid and detach the remote controller cable from the remote
controller terminal board.
2. Remove the remote controller
holding plate on the back side of
the front plate panel.
3. Fix the attached hole covering
plate on the front plate panel where
the remote controller was set.
Remote controller
terminal board
Remote controller wiring
Front plate
panel
Terminal box lid
Screw
(M4 × 2)
Screw (M4)
Front plate panel
Remote
controller
Remote controller
holding plate
Screw (M4 × 4)
Hole covering plate (6)
(attached)
Screw (M4 × 4)
Front plate panel
01_EN_3PA60136-8Y.fm Page 10 Saturday, December 22, 2007 1:04 PM