background image

7 Maintenance and service

Operation manual

14

40R2V1B

Daikin room air conditioner

3P485919-14U – 2021.03

NOTICE

Applicable  legislation  on 

fluorinated  greenhouse  gases

requires  that  the  refrigerant  charge  of  the  unit  is  indicated
both in weight and CO

2

 equivalent.

Formula  to  calculate  the  quantity  in  CO

2

  equivalent

tonnes:

  GWP  value  of  the  refrigerant  ×  total  refrigerant

charge [in kg] / 1000

Please contact your installer for more information.

WARNING

The  refrigerant  inside  the  unit  is  mildly  flammable,  but
normally  does  NOT  leak.  If  the  refrigerant  leaks  in  the
room  and  comes  in  contact  with  fire  from  a  burner,  a
heater, or a cooker, this may result in fire, or the formation
of a harmful gas.

Turn  off  any  combustible  heating  devices,  ventilate  the
room,  and  contact  the  dealer  where  you  purchased  the
unit.

Do  NOT  use  the  unit  until  a  service  person  confirms  that
the  part  from  which  the  refrigerant  leaked  has  been
repaired.

WARNING

▪ Do NOT pierce or burn refrigerant cycle parts.

▪ Do NOT use cleaning materials or means to accelerate

the  defrosting  process  other  than  those  recommended
by the manufacturer.

▪ Be  aware  that  the  refrigerant  inside  the  system  is

odourless.

WARNING

The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating  ignition  sources  (e.g.  open  flames,  an  operating
gas  appliance,  or  an  operating  electric  heater).  The  room
size shall be as specified in the General safety precaution.

NOTICE

Maintenance  MUST  be  done  by  an  authorized  installer  or
service agent.

We  recommend  performing  maintenance  at  least  once  a
year. However, applicable legislation might require shorter
maintenance intervals.

DANGER: RISK OF ELECTROCUTION

To  clean  the  air  conditioner  or  air  filter,  be  sure  to  stop
operation  and  turn  all  power  supplies  off.  Otherwise,  an
electric shock and injury may result.

WARNING

To prevent electrical shocks or fire:

▪ Do NOT rinse the unit.

▪ Do NOT operate the unit with wet hands.

▪ Do NOT place any objects containing water on the unit.

CAUTION

After  a  long  use,  check  the  unit  stand  and  fitting  for
damage. If damaged, the unit may fall and result in injury.

CAUTION

Do  NOT  touch  the  heat  exchanger  fins.  These  fins  are
sharp and could result in cutting injuries.

WARNING

Be careful with ladders when working in high places.

Following symbols may occur on the indoor unit:

Symbol

Explanation

Measure the voltage at the terminals of main circuit
capacitors or electrical components before servicing.

7.2

To clean the indoor unit and user
interface

WARNING

Improper  detergents  or  cleaning  procedure  may  cause
damage  on  plastic  components  or  water  leakage.
Splashed  detergent  on  electric  components,  such  as
motors, may cause failure, smoke or ignition.

NOTICE

▪ Do  NOT  use  gasoline,  benzene,  thinner,  polishing

powder  or  liquid  insecticide. 

Possible  consequence:

Discoloration and deformation.

▪ Do  NOT  use  water  or  air  of  40°C  or  higher. 

Possible

consequence: 

Discoloration and deformation.

▪ Do NOT use polishing compounds.

▪ Do 

NOT 

use 

scrubbing 

brush. 

Possible

consequence: 

The surface finishing peels off.

▪ As an end user, you may NEVER clean inside parts of

the unit by yourself; this work must be performed by a
qualified service person. Contact your dealer.

DANGER: RISK OF ELECTROCUTION

Before  cleaning,  be  sure  to  stop  the  operation,  turn  the
breaker  off  or  pull  out  the  supply  cord.  Otherwise,  an
electric shock and injury may result.

1

Clean  with  a  soft  cloth.  If  it  is  difficult  to  remove  stains,  use
water or a neutral detergent.

7.3

To clean the front panel

1

Clean the front panel with a soft cloth. If it is difficult to remove
stains, use water or a neutral detergent.

7.4

To remove the front panel

1

Hold the front panel by the panel tabs on both sides and open
it.

2

Remove  the  front  panel  by  sliding  it  to  the  left  or  the  right  and
pulling it toward you.

Result: 

The front panel shaft on 1 side will be disconnected.

Summary of Contents for FTXTM30R2V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXTM30R2V1B FTXTM40R2V1B ...

Page 2: ...ion 11 5 10 5 To delete reservations 11 5 11 Wireless LAN connection 11 5 11 1 Precautions when using the wireless LAN 12 5 11 2 To install the Daikin Residential Controller application 12 5 11 3 To set the wireless connection 12 6 Energy saving and optimum operation 13 7 Maintenance and service 13 7 1 Overview Maintenance and service 13 7 2 To clean the indoor unit and user interface 14 7 3 To cl...

Page 3: ...ittle children plants or animals directly to the airflow WARNING Do NOT place a flammable spray bottle near the air conditioner and do NOT use sprays near the unit Doing so may result in a fire CAUTION Do NOT operate the system when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals WARNING The refriger...

Page 4: ...CE Do NOT use the system for other purposes In order to avoid any quality deterioration do NOT use the unit for cooling precision instruments food plants animals or works of art 3 1 Indoor unit CAUTION Do NOT insert fingers rods or other objects into the air inlet or outlet When the fan is rotating at high speed it will cause injury INFORMATION The sound pressure level is less than 70 dBA WARNING ...

Page 5: ...uttons k Weekly timer operation buttons l Flash Streamer and Fireplace logic operation button m Econo and Outdoor unit quiet operation button n Mode button o Powerful button p Fan button 3 2 2 To operate the user interface a a Signal receiver 1 Aim the signal transmitter at the signal receiver on the indoor unit maximum distance for communication is 7 m Result When the indoor unit receives a signa...

Page 6: ...s cooling drying and automatic are NOT available for the heating only version of the product Setting Description Automatic The system cools down or heats up a room to the temperature setpoint It automatically switches between cooling and heating if necessary Drying The system decreases the humidity in a room Heating The system heats up a room to the temperature setpoint Cooling The system cools do...

Page 7: ...rection 1 Press Result appears on the LCD The flaps horizontal blades will begin to swing 2 To use fixed position press when the flaps reach the desired position Result disappears from the LCD The flaps will stop moving 5 4 2 To adjust horizontal airflow direction 1 Press Result appears on the LCD The louvers vertical blades will begin to swing 2 To use fixed position press when the louvers reach ...

Page 8: ...the LCD Note Powerful operation can be set only when the unit is running If you press or if you change operation mode operation will be cancelled disappears from the LCD 5 7 Econo and Outdoor unit quiet operation 5 7 1 Econo operation This is a function which enables efficient operation by limiting the maximum power consumption value This function is useful for cases in which attention should be p...

Page 9: ...il both symbols disappear from the LCD 5 9 OFF ON timer operation Timer functions are useful for automatically switching the air conditioner off on at night or in the morning You can also use OFF timer and ON timer in combination INFORMATION Program the timer again in case of A breaker has turned the unit off A power failure After replacing batteries in the user interface INFORMATION The clock MUS...

Page 10: ...4 3 To set the clock 45 INFORMATION Weekly timer and OFF ON timer operation CANNOT be used at the same time The OFF ON timer operation takes priority Weekly timer will be in standby disappears from the LCD When the OFF ON timer is completed the Weekly timer becomes active The day of the week OFF ON timer mode time and temperature only for ON timer can be set with the Weekly timer Other settings ar...

Page 11: ...timer operation 1 To deactivate the Weekly timer press while is displayed on the LCD Result disappears from the LCD and the timer lamp goes off 2 To reactivate the Weekly timer press again Result The last set reservation mode will be used 5 10 5 To delete reservations To delete individual reservations Use this function if you want to delete a single reservation setting 1 Press Result The day of th...

Page 12: ...reen menu press and hold for at least 5 seconds while the unit is not operating Result The SP wireless connection setting menu appears is blinking 5 sec 2 Press to confirm the selection Result is blinking 3 Check the operation and timer LEDs on the indoor unit display ON OFF a b a Operation LED b Timer LED If operation LED and timer LED then wireless LAN is blinks blinks not connected is off blink...

Page 13: ...n to the default screen To turn off the wireless LAN connection If you want to turn off the wireless connection function 1 On home screen menu press for at least 5 seconds while the unit is not operating Result The SP menu appears is blinking 2 Change to the SP menu by pressing once or repeatedly 1 5 sec 3 Hold for at least 2 seconds to confirm the selection Result is blinking The operation and ti...

Page 14: ...nd injury may result WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet hands Do NOT place any objects containing water on the unit CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury CAUTION Do NOT touch the heat exchanger fins These fins are sharp and could result in cutting injuri...

Page 15: ...for about 10 to 15 minutes INFORMATION If the dust does NOT come off easily wash them with a neutral detergent diluted in lukewarm water Dry the air filters in the shade It is recommended to clean the air filters every 2 weeks 7 6 To clean the titanium apatite deodorising filter and the silver particle filter Ag ion filter INFORMATION Clean the filter with water every 6 months 1 Remove for class 3...

Page 16: ...y after several seasons of use This results in poor performance 7 9 1 Winter season NOTICE Any icicles on the outdoor unit MUST be removed Use gloves to avoid injury and damage to the unit 8 Troubleshooting If one of the following malfunctions occur take the measures shown below and contact your dealer WARNING Stop operation and shut off the power if anything unusual occurs burning smells etc Leav...

Page 17: ...19 14U 2021 03 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recovery ...

Page 18: ......

Page 19: ......

Page 20: ...3P485919 14U 2021 03 Copyright 2021 Daikin Verantwortung für Energie und Umwelt ...

Reviews: