background image

5 Operation

Operation manual

8

40R2V1B

Daikin room air conditioner

3P485919-14U – 2021.03

About the Intelligent eye sensor

NOTICE

▪ Do NOT hit or push the Intelligent eye sensor. Doing so

may lead to malfunction.

▪ Do  NOT  place  large  objects  near  the  Intelligent  eye

sensor.

INFORMATION

Powerful  or  Night  set  operation  CANNOT  be  used  at  the
same time with Intelligent eye operation. The last selected
function takes priority.

Detection sensitivity.

 Changes according to location, the number

of persons in the room, temperature range, etc.

Detection  mistakes.

  The  sensor  may  mistakenly  detect  pets,

sunlight, moving curtains, etc.

5.5.3

To start/stop Comfort and Intelligent eye
operation

1

Press 

 one or more times.

Result: 

The setting will change as follows:

Display

Operation

Comfort airflow

Intelligent eye

+

Comfort airflow and Intelligent eye

Both deactivated

Note:

 If there are people close to the front of the indoor unit or there

are too many people, use both operations at the same time.

2

To  stop  operation,  press 

  until  both  symbols  disappear

from the LCD.

5.6

Powerful operation

This  operation  quickly  maximizes  the  cooling/heating  effect  in  any
operation mode. You can get the maximum capacity.

INFORMATION

Powerful operation CANNOT be used together with Econo,
Comfort  airflow,  Intelligent  eye  and  Outdoor  unit  quiet
operation. The last selected function takes priority.

Powerful  operation  will  NOT  increase  the  capacity  of  the
unit if it already operates at maximum capacity.

5.6.1

To start/stop Powerful operation

1

Press 

 to start.

Result: 

  is  displayed  on  the  LCD.  Powerful  operation  runs

for 20 minutes; after that, operation returns to the previously set
mode.

2

Press 

 to stop.

Result: 

 disappears from the LCD.

Note:

 Powerful operation can be set only when the unit is running. If

you  press 

  or  if  you  change  operation  mode,  operation  will  be

cancelled; 

 disappears from the LCD.

5.7

Econo and Outdoor unit quiet
operation

5.7.1

Econo operation

This  is  a  function  which  enables  efficient  operation  by  limiting  the
maximum power consumption value. This function is useful for cases
in which attention should be paid to ensure a circuit breaker will not
trip when the product runs alongside other appliances.

INFORMATION

▪ Powerful and Econo operation CANNOT be used at the

same time. The last selected function takes priority.

▪ Econo  operation  reduces  power  consumption  of  the

outdoor  unit  by  limiting  the  rotation  speed  of  the
compressor.  If  power  consumption  is  already  low,
Econo  operation  will  NOT  further  reduce  power
consumption.

5.7.2

Outdoor unit quiet operation

Use  Outdoor  unit  quiet  operation  when  you  want  to  decrease  the
noise level of the outdoor unit. 

Example: 

At night.

INFORMATION

▪ Powerful and Outdoor unit quiet operation CANNOT be

used at the same time. The last selected function takes
priority.

▪ This  function  is  only  available  in  Automatic,  Cooling,

and Heating operation.

▪ Outdoor unit quiet operation limits the rotation speed of

the compressor. If the rotation speed of compressor is
already  low,  Outdoor  unit  quiet  operation  will  NOT
further reduce the compressor rotation speed.

5.7.3

To start/stop Econo and Outdoor unit
quiet operation

1

Press 

 one or more times.

Result: 

The setting will change as follows.

Display

Operation

Econo

Outdoor unit quiet

+

Econo and Outdoor unit quiet

Both deactivated

2

To  stop  operation,  press 

  until  both  symbols  disappear

from the LCD.

Note: 

Econo  operation  can  be  only  set  when  the  unit  is  running.

Pressing 

 cancels the setting and 

 disappears from the LCD.

Note: 

  remains  on  the  LCD,  even  if  you  turn  off  the  unit  using

the user interface or indoor unit ON/OFF switch.

Summary of Contents for FTXTM30R2V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXTM30R2V1B FTXTM40R2V1B ...

Page 2: ...ion 11 5 10 5 To delete reservations 11 5 11 Wireless LAN connection 11 5 11 1 Precautions when using the wireless LAN 12 5 11 2 To install the Daikin Residential Controller application 12 5 11 3 To set the wireless connection 12 6 Energy saving and optimum operation 13 7 Maintenance and service 13 7 1 Overview Maintenance and service 13 7 2 To clean the indoor unit and user interface 14 7 3 To cl...

Page 3: ...ittle children plants or animals directly to the airflow WARNING Do NOT place a flammable spray bottle near the air conditioner and do NOT use sprays near the unit Doing so may result in a fire CAUTION Do NOT operate the system when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals WARNING The refriger...

Page 4: ...CE Do NOT use the system for other purposes In order to avoid any quality deterioration do NOT use the unit for cooling precision instruments food plants animals or works of art 3 1 Indoor unit CAUTION Do NOT insert fingers rods or other objects into the air inlet or outlet When the fan is rotating at high speed it will cause injury INFORMATION The sound pressure level is less than 70 dBA WARNING ...

Page 5: ...uttons k Weekly timer operation buttons l Flash Streamer and Fireplace logic operation button m Econo and Outdoor unit quiet operation button n Mode button o Powerful button p Fan button 3 2 2 To operate the user interface a a Signal receiver 1 Aim the signal transmitter at the signal receiver on the indoor unit maximum distance for communication is 7 m Result When the indoor unit receives a signa...

Page 6: ...s cooling drying and automatic are NOT available for the heating only version of the product Setting Description Automatic The system cools down or heats up a room to the temperature setpoint It automatically switches between cooling and heating if necessary Drying The system decreases the humidity in a room Heating The system heats up a room to the temperature setpoint Cooling The system cools do...

Page 7: ...rection 1 Press Result appears on the LCD The flaps horizontal blades will begin to swing 2 To use fixed position press when the flaps reach the desired position Result disappears from the LCD The flaps will stop moving 5 4 2 To adjust horizontal airflow direction 1 Press Result appears on the LCD The louvers vertical blades will begin to swing 2 To use fixed position press when the louvers reach ...

Page 8: ...the LCD Note Powerful operation can be set only when the unit is running If you press or if you change operation mode operation will be cancelled disappears from the LCD 5 7 Econo and Outdoor unit quiet operation 5 7 1 Econo operation This is a function which enables efficient operation by limiting the maximum power consumption value This function is useful for cases in which attention should be p...

Page 9: ...il both symbols disappear from the LCD 5 9 OFF ON timer operation Timer functions are useful for automatically switching the air conditioner off on at night or in the morning You can also use OFF timer and ON timer in combination INFORMATION Program the timer again in case of A breaker has turned the unit off A power failure After replacing batteries in the user interface INFORMATION The clock MUS...

Page 10: ...4 3 To set the clock 45 INFORMATION Weekly timer and OFF ON timer operation CANNOT be used at the same time The OFF ON timer operation takes priority Weekly timer will be in standby disappears from the LCD When the OFF ON timer is completed the Weekly timer becomes active The day of the week OFF ON timer mode time and temperature only for ON timer can be set with the Weekly timer Other settings ar...

Page 11: ...timer operation 1 To deactivate the Weekly timer press while is displayed on the LCD Result disappears from the LCD and the timer lamp goes off 2 To reactivate the Weekly timer press again Result The last set reservation mode will be used 5 10 5 To delete reservations To delete individual reservations Use this function if you want to delete a single reservation setting 1 Press Result The day of th...

Page 12: ...reen menu press and hold for at least 5 seconds while the unit is not operating Result The SP wireless connection setting menu appears is blinking 5 sec 2 Press to confirm the selection Result is blinking 3 Check the operation and timer LEDs on the indoor unit display ON OFF a b a Operation LED b Timer LED If operation LED and timer LED then wireless LAN is blinks blinks not connected is off blink...

Page 13: ...n to the default screen To turn off the wireless LAN connection If you want to turn off the wireless connection function 1 On home screen menu press for at least 5 seconds while the unit is not operating Result The SP menu appears is blinking 2 Change to the SP menu by pressing once or repeatedly 1 5 sec 3 Hold for at least 2 seconds to confirm the selection Result is blinking The operation and ti...

Page 14: ...nd injury may result WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet hands Do NOT place any objects containing water on the unit CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury CAUTION Do NOT touch the heat exchanger fins These fins are sharp and could result in cutting injuri...

Page 15: ...for about 10 to 15 minutes INFORMATION If the dust does NOT come off easily wash them with a neutral detergent diluted in lukewarm water Dry the air filters in the shade It is recommended to clean the air filters every 2 weeks 7 6 To clean the titanium apatite deodorising filter and the silver particle filter Ag ion filter INFORMATION Clean the filter with water every 6 months 1 Remove for class 3...

Page 16: ...y after several seasons of use This results in poor performance 7 9 1 Winter season NOTICE Any icicles on the outdoor unit MUST be removed Use gloves to avoid injury and damage to the unit 8 Troubleshooting If one of the following malfunctions occur take the measures shown below and contact your dealer WARNING Stop operation and shut off the power if anything unusual occurs burning smells etc Leav...

Page 17: ...19 14U 2021 03 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recovery ...

Page 18: ......

Page 19: ......

Page 20: ...3P485919 14U 2021 03 Copyright 2021 Daikin Verantwortung für Energie und Umwelt ...

Reviews: