background image

Table of contents

Installation manual

2

FTXTA30A2V1BW

Split system air conditioner

3P482320-9M – 2019.04

Table of contents

1 About the documentation

2

1.1

About this document..................................................................

2

2 About the box

2

2.1

Indoor unit .................................................................................

2

2.1.1

To remove the accessories from the indoor unit.........

2

3 About the unit

3

3.1

System layout ............................................................................

3

3.2

About the wireless LAN adapter................................................

3

3.2.1

Precautions when using the wireless adapter.............

3

3.2.2

Basic parameters ........................................................

3

4 Preparation

3

4.1

Preparing the installation site ....................................................

3

4.1.1

Installation site requirements of the indoor unit ..........

3

5 Installation

3

5.1

Opening the indoor unit .............................................................

3

5.1.1

To open the front panel...............................................

3

5.1.2

To close the front panel ..............................................

4

5.1.3

To remove the front panel...........................................

4

5.1.4

To open the service cover...........................................

4

5.1.5

To remove the front grille ............................................

4

5.1.6

To re-install the front grille ..........................................

5

5.1.7

To remove the electrical wiring box cover...................

5

5.2

Installing the indoor unit ............................................................

5

5.2.1

To install the mounting plate .......................................

5

5.2.2

To drill a wall hole .......................................................

6

5.2.3

To remove the pipe port cover ....................................

6

5.2.4

To provide drainage ....................................................

6

5.3

Connecting the refrigerant piping ..............................................

7

5.3.1

To connect the refrigerant piping to the indoor unit ....

7

5.4

Connecting the electrical wiring.................................................

7

5.4.1

To connect the electrical wiring on the indoor unit......

8

5.4.2

To connect optional accessories (wired user
interface, central user interface, etc.)..........................

8

5.5

Finishing the indoor unit installation ..........................................

8

5.5.1

To insulate the drain piping, refrigerant piping and
interconnection cable ..................................................

8

5.5.2

To pass the pipes through the wall hole .....................

9

5.5.3

To fix the unit on the mounting plate...........................

9

6 Commissioning

9

6.1

Checklist before commissioning ................................................

9

6.2

To perform a test run .................................................................

9

6.2.1

To perform a test run using the user interface ............ 10

7 Technical data

10

7.1

Wiring diagram ..........................................................................

10

7.1.1

Unified wiring diagram legend..................................... 10

1

About the documentation

1.1

About this document

INFORMATION

Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.

Target audience

Authorised installers

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

WARNING

Make  sure  installation,  servicing,  maintenance,  repair  and
applied materials follow the instructions from Daikin and, in
addition,  comply  with  applicable  legislation  and  are
performed  by  qualified  persons  only.  In  Europe  and  areas
where  IEC  standards  apply,  EN/IEC  60335-2-40  is  the
applicable standard.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you MUST read before installing

▪ Format: Paper (in the box of the indoor unit)

Indoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer reference guide:

▪ Preparation of the installation, good practices, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

extranet (authentication required).

2

About the box

2.1

Indoor unit

2.1.1

To remove the accessories from the
indoor unit

e

d

b

a

c

f

g

j

k

h

i

a

Installation manual

b

Operation manual

c

General safety precautions

d

Titanium apatite deodorizing filter and silver particle filter
(Ag-ion filter)

e

Indoor unit fixing screw (M4×12L). Refer to 

"5.5.3 To fix the

unit on the mounting plate" on page 9

.

f

Dry battery AAA.LR03 (alkaline) for user interface

g

User interface holder

h

User interface

i

Mounting plate

j

Screw cover

k

Spare SSID sticker with release paper (attached to the
unit)

Summary of Contents for FTXTA30A2V1BW

Page 1: ...Installation manual Split system air conditioner English Installation manual Split system air conditioner FTXTA30A2V1BW ...

Page 2: ...on and ask him her to keep it for future reference Target audience Authorised installers INFORMATION This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial and household use by lay persons WARNING Make sure installation servicing maintenance repair and applied materials follow the instructions from Daikin and in addition comply wi...

Page 3: ...ency range 2400 MHz 2483 5 MHz Radio protocol IEEE 802 11b g n Radio frequency channel 1 11 Output power 0 dBm 18 dBm Parameter Value Effective radiated power 17 dBm 11b 13 dBm 11g 12 dBm 11n Power supply DC 3 3 V 500 mA 4 Preparation 4 1 Preparing the installation site WARNING The appliance shall be stored so as to prevent mechanical damage and in a well ventilated room without continuously opera...

Page 4: ...ide a a a Panel lock 3 Push the right arm lightly to the right to disconnect the shaft from the shaft slot on the right side a c b a Arm b Shaft c Shaft slot 4 Disconnect the front panel shaft from the shaft slot on the left side a c b a Arm b Shaft slot c Shaft 5 Remove the front panel 6 To re install the front panel perform the steps in the opposite order 5 1 4 To open the service cover 1 Remove...

Page 5: ...re clamp 5 Close the front panel Refer to 5 1 2 To close the front panel on page 4 5 1 7 To remove the electrical wiring box cover 1 Remove the front grille 2 Remove 1 screw from the electrical wiring box 3 Open the electrical wiring box cover by pulling it to the front 4 Remove the electrical wiring box cover from the 2 rear hooks 1 2 b a c c a Screw b Electrical wiring box c Rear hook 5 To re in...

Page 6: ...ial field supply in order to prevent water leakage 1 Bore a 65 mm large feed through hole in the wall with a downward slope towards the outside 2 Insert a wall embedded pipe into the hole 3 Insert a wall cover into the wall pipe Ø65 a b c a Wall embedded pipe b Putty c Wall hole cover 4 After completing wiring refrigerant piping and drain piping do NOT forget to seal the gap with putty 5 2 3 To re...

Page 7: ...cur a b a b a Insulation fixing screw b Drain hose 4 Attach the drain hose to the refrigerant pipes bottom side using adhesive vinyl tape A B C b a A Left side piping B Left back piping C Left bottom piping a Remove the pipe port cover here for left side piping b Remove the pipe port cover here for left bottom piping To check for water leaks 1 Remove the air filters 2 Gradually pour approximately ...

Page 8: ... may NOT run parallel In order to avoid any electrical interference the distance between both wirings should ALWAYS be at least 50 mm WARNING Provide adequate measures to prevent that the unit can be used as a shelter by small animals Small animals that make contact with electrical parts can cause malfunctions smoke or fire a b c a Terminal block b Electrical component block c Wire retainer 5 Stri...

Page 9: ... reference guide The indoor units are properly mounted The outdoor unit is properly mounted Air inlet outlet Check that the air inlet and outlet of the unit is NOT obstructed by paper sheets cardboard or any other material There are NO missing phases or reversed phases The refrigerant pipes gas and liquid are thermally insulated Drainage Make sure drainage flows smoothly Possible consequence Conde...

Page 10: ...OUTDOOR Outdoor unit Wire clamp Symbol Colour Symbol Colour BLK Black ORG Orange BLU Blue PNK Pink BRN Brown PRP PPL Purple GRN Green RED Red GRY Grey WHT White YLW Yellow Symbol Meaning A P Printed circuit board BS Pushbutton ON OFF operation switch BZ H C Buzzer C Capacitor AC CN E HA HE HL HN HR MR _A MR _B S U V W X A K R_ Connection connector D V D Diode DB Diode bridge DS DIP switch E H Heat...

Page 11: ...l strip fixed plate T R Transformer TC TRC Transmitter V R V Varistor V R Diode bridge WRC Wireless remote controller X Terminal X M Terminal strip block Y E Electronic expansion valve coil Y R Y S Reversing solenoid valve coil Z C Ferrite core ZF Z F Noise filter A P Printed circuit board BS Pushbutton ON OFF operation switch BZ H C Buzzer C Capacitor AC CN E HA HE HL HN HR MR _A MR _B S U V W X ...

Page 12: ...3P482320 9M 2019 04 Copyright 2019 Daikin ...