background image

5 Installation

Installation manual

4

FTXTA30A2V1BW

Split system air conditioner

3P482320-9M – 2019.04

2

Pull down both locks on the back of the front panel.

3

Open the front panel until the support fits into the fixing tab.

a

d

c

b

a

Lock (1 on each side)

b

Backside of the front panel

c

Fixing tab

d

Support

5.1.2

To close the front panel

1

Lift  the  front  panel  slightly  and  remove  the  support  from  the
fixing tab.

a

b

c

a

Backside of the front panel

b

Fixing tab

c

Support

2

Close the front panel.

3

Gently press the front panel down until it clicks.

5.1.3

To remove the front panel

INFORMATION

Remove the front panel only in case it MUST be replaced.

1

Open  the  front  panel.  See 

"5.1.1  To  open  the  front  panel"  on

page 3

.

2

Open  the  panel  locks  located  on  the  back  side  of  the  panel
(1 on each side).

a

a

a

Panel lock

3

Push  the  right  arm  lightly  to  the  right  to  disconnect  the  shaft
from the shaft slot on the right side.

a

c

b

a

Arm

b

Shaft

c

Shaft slot

4

Disconnect  the  front  panel  shaft  from  the  shaft  slot  on  the  left
side.

a

c

b

a

Arm

b

Shaft slot

c

Shaft

5

Remove the front panel.

6

To  re-install  the  front  panel  perform  the  steps  in  the  opposite
order.

5.1.4

To open the service cover

1

Remove 1 screw from the service cover.

2

Pull out the service cover horizontally away from the unit.

a

b

a

Service cover screw

b

Service cover

5.1.5

To remove the front grille

CAUTION

Wear protective gloves.

1

Open  the  front  panel.  Refer  to 

"5.1.1  To  open  the  front

panel" on page 3

.

2

Remove the service cover. Refer to 

"5.1.4 To open the service

cover" on page 4

.

3

Remove  the  wire  harness  from  the  wire  clamp  and  the
connector.

4

Remove the flap by pushing it to the left side and towards you.

5

Remove  the  2  screw  covers  using  a  long  flat  plate  such  as  a
ruler wrapped in a cloth and remove 2 screws.

Summary of Contents for FTXTA30A2V1BW

Page 1: ...Installation manual Split system air conditioner English Installation manual Split system air conditioner FTXTA30A2V1BW ...

Page 2: ...on and ask him her to keep it for future reference Target audience Authorised installers INFORMATION This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial and household use by lay persons WARNING Make sure installation servicing maintenance repair and applied materials follow the instructions from Daikin and in addition comply wi...

Page 3: ...ency range 2400 MHz 2483 5 MHz Radio protocol IEEE 802 11b g n Radio frequency channel 1 11 Output power 0 dBm 18 dBm Parameter Value Effective radiated power 17 dBm 11b 13 dBm 11g 12 dBm 11n Power supply DC 3 3 V 500 mA 4 Preparation 4 1 Preparing the installation site WARNING The appliance shall be stored so as to prevent mechanical damage and in a well ventilated room without continuously opera...

Page 4: ...ide a a a Panel lock 3 Push the right arm lightly to the right to disconnect the shaft from the shaft slot on the right side a c b a Arm b Shaft c Shaft slot 4 Disconnect the front panel shaft from the shaft slot on the left side a c b a Arm b Shaft slot c Shaft 5 Remove the front panel 6 To re install the front panel perform the steps in the opposite order 5 1 4 To open the service cover 1 Remove...

Page 5: ...re clamp 5 Close the front panel Refer to 5 1 2 To close the front panel on page 4 5 1 7 To remove the electrical wiring box cover 1 Remove the front grille 2 Remove 1 screw from the electrical wiring box 3 Open the electrical wiring box cover by pulling it to the front 4 Remove the electrical wiring box cover from the 2 rear hooks 1 2 b a c c a Screw b Electrical wiring box c Rear hook 5 To re in...

Page 6: ...ial field supply in order to prevent water leakage 1 Bore a 65 mm large feed through hole in the wall with a downward slope towards the outside 2 Insert a wall embedded pipe into the hole 3 Insert a wall cover into the wall pipe Ø65 a b c a Wall embedded pipe b Putty c Wall hole cover 4 After completing wiring refrigerant piping and drain piping do NOT forget to seal the gap with putty 5 2 3 To re...

Page 7: ...cur a b a b a Insulation fixing screw b Drain hose 4 Attach the drain hose to the refrigerant pipes bottom side using adhesive vinyl tape A B C b a A Left side piping B Left back piping C Left bottom piping a Remove the pipe port cover here for left side piping b Remove the pipe port cover here for left bottom piping To check for water leaks 1 Remove the air filters 2 Gradually pour approximately ...

Page 8: ... may NOT run parallel In order to avoid any electrical interference the distance between both wirings should ALWAYS be at least 50 mm WARNING Provide adequate measures to prevent that the unit can be used as a shelter by small animals Small animals that make contact with electrical parts can cause malfunctions smoke or fire a b c a Terminal block b Electrical component block c Wire retainer 5 Stri...

Page 9: ... reference guide The indoor units are properly mounted The outdoor unit is properly mounted Air inlet outlet Check that the air inlet and outlet of the unit is NOT obstructed by paper sheets cardboard or any other material There are NO missing phases or reversed phases The refrigerant pipes gas and liquid are thermally insulated Drainage Make sure drainage flows smoothly Possible consequence Conde...

Page 10: ...OUTDOOR Outdoor unit Wire clamp Symbol Colour Symbol Colour BLK Black ORG Orange BLU Blue PNK Pink BRN Brown PRP PPL Purple GRN Green RED Red GRY Grey WHT White YLW Yellow Symbol Meaning A P Printed circuit board BS Pushbutton ON OFF operation switch BZ H C Buzzer C Capacitor AC CN E HA HE HL HN HR MR _A MR _B S U V W X A K R_ Connection connector D V D Diode DB Diode bridge DS DIP switch E H Heat...

Page 11: ...l strip fixed plate T R Transformer TC TRC Transmitter V R V Varistor V R Diode bridge WRC Wireless remote controller X Terminal X M Terminal strip block Y E Electronic expansion valve coil Y R Y S Reversing solenoid valve coil Z C Ferrite core ZF Z F Noise filter A P Printed circuit board BS Pushbutton ON OFF operation switch BZ H C Buzzer C Capacitor AC CN E HA HE HL HN HR MR _A MR _B S U V W X ...

Page 12: ...3P482320 9M 2019 04 Copyright 2019 Daikin ...

Reviews: