SiBE041213E
Troubleshooting
Service Diagnosis
68
Troubleshooting
Check No.11
Refer to P.93
Check No.11
Check the power supply
waveform.
Check the voltage of the
connection wires on the indoor
terminal board between No. 1
and No. 3, and between No. 2
and No. 3.
YES
YES
Replace the indoor unit PCB.
Locate the cause of the
disturbance of the power
supply waveform, and correct
it.
NO
(R18180)
NO
YES
YES
NO
NO
Caution
Correct the indoor unit -
outdoor unit connection wires.
Diagnose the outdoor unit
PCB.
Replace the connection wires
between the indoor unit and
outdoor unit.
Is LED A blinking?
Properly insulated?
Is there any disturbance?
Is there any wiring error?
Check the indoor unit - outdoor
unit connection wires.
Check the LED A on the outdoor
unit PCB.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
∗
Before you check the LED A, cancel
the standby electricity saving
function by starting fan operation
with the remote controller.
∗
Wait at least for 7 sec. after turning
on the power.
NO
YES
Check the power supply voltage.
Correct the power supply.
YES
NO
Replace both the fan motor
and the outdoor unit PCB.
Rotate the
outdoor fan by hand.
Does the outdoor fan
rotate smoothly?
Is the
power supply
voltage fluctuation within
±10% from the rated
value?
Summary of Contents for FTXS35K2V1B
Page 12: ...SiBE041213E 1 List of Functions Part 1 List of Functions 1 Functions 2...
Page 14: ...SiBE041213E 3 Specifications Part 2 Specifications 1 Specifications 4...
Page 59: ...SiBE041213E Remote Controller 48 Part 5 Remote Controller 1 Remote Controller 49...
Page 129: ...Revision History Month Year Version Revised contents 05 2013 SiBE041213E First edition...