![background image](http://html2.mh-extra.com/html/daikin/ftxs35k2v1b/ftxs35k2v1b_service-manual_4199899024.webp)
Outdoor Unit
SiBE041213E
13
Printed Circuit Board Connector Wiring Diagram
Filter PCB
1) S11
Connector for [S10] on main PCB
2) HL1, HN1, S
Connector for terminal board
3) E1, E2
Terminal for earth wire
4) HL2, HN2
Connector for [HL3] [HN3] on main PCB
5) HL4, HN4
Connector for [S12] on main PCB
6) FU1
Fuse (3.15 A, 250 V)
7) FU3
Fuse (30 A, 250 V)
8) V2, V3
Varistor
9) SW1
Forced cooling operation ON/OFF switch
∗
Refer to page 104 for detail.
S
HL1
HN1
V3
V2
FU3
SW1
FU1
HN4, HL4
HN2 HL2
S11
E2, E1
3P273862-4
S50
(on main PCB)
Summary of Contents for FTXS35K2V1B
Page 12: ...SiBE041213E 1 List of Functions Part 1 List of Functions 1 Functions 2...
Page 14: ...SiBE041213E 3 Specifications Part 2 Specifications 1 Specifications 4...
Page 59: ...SiBE041213E Remote Controller 48 Part 5 Remote Controller 1 Remote Controller 49...
Page 129: ...Revision History Month Year Version Revised contents 05 2013 SiBE041213E First edition...