7 Maintenance and service

Operation manual

9

FTXP-N
Daikin room air conditioner
3P511999-8Q – 2022.06

CAUTION

NEVER  expose  little  children,  plants  or  animals  directly  to
the airflow.

NOTICE

Do NOT place objects below the indoor and/or outdoor unit
that  may  get  wet.  Otherwise  condensation  on  the  unit  or
refrigerant pipes, air filter dirt or drain blockage may cause
dripping,  and  objects  under  the  unit  may  get  dirty  or
damaged.

WARNING

Do  NOT  place  a  flammable  spray  bottle  near  the  air
conditioner and do NOT use sprays near the unit. Doing so
may result in a fire.

CAUTION

Do  NOT  operate  the  system  when  using  a  room
fumigation-type  insecticide.  Chemicals  could  collect  in  the
unit,  and  endanger  the  health  of  people  who  are
hypersensitive to chemicals.

7

Maintenance and service

7.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance.

About the refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R32

Global warming potential (GWP) value: 675

NOTICE

Applicable  legislation  on 

fluorinated  greenhouse  gases

requires  that  the  refrigerant  charge  of  the  unit  is  indicated
both in weight and CO

2

 equivalent.

Formula  to  calculate  the  quantity  in  CO

2

  equivalent

tonnes:

  GWP  value  of  the  refrigerant  ×  total  refrigerant

charge [in kg] / 1000

Please contact your installer for more information.

WARNING

▪ The  refrigerant  inside  the  unit  is  mildly  flammable,  but

normally  does  NOT  leak.  If  the  refrigerant  leaks  in  the
room  and  comes  in  contact  with  fire  from  a  burner,  a
heater,  or  a  cooker,  this  may  result  in  fire,  or  the
formation of a harmful gas.

▪ Turn  OFF  any  combustible  heating  devices,  ventilate

the room, and contact the dealer where you purchased
the unit.

▪ Do  NOT  use  the  unit  until  a  service  person  confirms

that the part from which the refrigerant leaked has been
repaired.

WARNING

▪ Do NOT pierce or burn refrigerant cycle parts.

▪ Do NOT use cleaning materials or means to accelerate

the  defrosting  process  other  than  those  recommended
by the manufacturer.

▪ Be  aware  that  the  refrigerant  inside  the  system  is

odourless.

NOTICE

Maintenance  MUST  be  done  by  an  authorised  installer  or
service agent.

We  recommend  performing  maintenance  at  least  once  a
year. However, applicable legislation might require shorter
maintenance intervals.

DANGER: RISK OF ELECTROCUTION

To  clean  the  air  conditioner  or  air  filter,  be  sure  to  stop
operation  and  turn  all  power  supplies  OFF.  Otherwise,  an
electrical shock and injury may result.

WARNING

To prevent electrical shocks or fire:

▪ Do NOT rinse the unit.

▪ Do NOT operate the unit with wet hands.

▪ Do NOT place any objects containing water on the unit.

CAUTION

After  a  long  use,  check  the  unit  stand  and  fitting  for
damage. If damaged, the unit may fall and result in injury.

CAUTION

Do  NOT  touch  the  heat  exchanger  fins.  These  fins  are
sharp and could result in cutting injuries.

WARNING

Be careful with ladders when working in high places.

Following symbols may occur on the indoor unit:

Symbol

Explanation

Measure the voltage at the terminals of main circuit
capacitors or electrical components before servicing.

7.2

To clean the indoor unit and
wireless remote control

WARNING

Improper  detergents  or  cleaning  procedure  may  cause
damage  on  plastic  components  or  water  leakage.
Splashed  detergent  on  electric  components,  such  as
motors, may cause failure, smoke or ignition.

Summary of Contents for FTXP50N2V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXP50N2V1B FTXP60N2V1B FTXP71N2V1B...

Page 2: ...the titanium apatite deodorising filter and the silver particle filter Ag ion filter 10 7 7 To replace the titanium apatite deodorising filter and the silver particle filter Ag ion filter 11 7 8 To cl...

Page 3: ...T operate the system when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals WARNING The refrigerant ins...

Page 4: ...ely safe non toxic and mildly flammable but it will generate toxic gas when it accidentally leaks into a room where combustible air from fan heaters gas cookers etc is present Always have qualified se...

Page 5: ...ear 1 Remove the back cover 2 Insert both batteries at once 3 Put the cover back 2 3 1 AAA LR03 4 2 To mount the wireless remote control holder c b a 2 a Wireless remote control b Screws field supply...

Page 6: ...by pressing one of the following buttons Mode Press Result Automatic operation The operation lamp lights up Cooling operation Drying operation Heating operation Fan only operation 2 Press or on the bu...

Page 7: ...5 1 To start stop Comfort airflow operation 1 Press to start Result The flap position will change is displayed on the LCD and the airflow rate is set to automatic Mode Position of flap Cooling Drying...

Page 8: ...ing disappear from the LCD and the timer lamp goes off 5 8 3 To combine OFF timer and ON timer 1 To set the timers refer to 5 8 1 To start stop OFF timer operation 4 8 and 5 8 2 To start stop ON timer...

Page 9: ...fire or the formation of a harmful gas Turn OFF any combustible heating devices ventilate the room and contact the dealer where you purchased the unit Do NOT use the unit until a service person confi...

Page 10: ...front panel with a soft cloth If it is difficult to remove stains use water or a neutral detergent 7 4 To open the front panel 1 Hold the front panel by the panel tabs on both sides and open it 7 5 T...

Page 11: ...fter several seasons of use This results in poor performance 8 Troubleshooting If one of the following malfunctions occur take the measures shown below and contact your dealer WARNING Stop operation a...

Page 12: ...3P511999 8Q 2022 06 Copyright 2022 Daikin Verantwortung f r Energie und Umwelt...

Reviews: