background image

5 Operation

Operation manual

6

FTXP-N

Daikin room air conditioner

3P511999-8Q – 2022.06

(a)

A safety device might stop the operation of the system if the unit
runs outside its operation range.

(b)

Condensation and water dripping might occur if the unit runs
outside its operation range.

5.2

Operation mode and temperature
setpoint

When.

  Adjust  the  system  operation  mode  and  set  the  temperature

when you want to:

▪ Heat up or cool down a room

▪ Blow air in a room without heating or cooling

▪ Decrease the humidity in a room

What.

  The  system  operates  differently,  depending  on  the  user

selection.

Setting

Description

 Automatic

The system cools down or heats up a
room to the temperature setpoint. It
automatically switches between cooling
and heating if necessary.

 Drying

The system decreases the humidity in a
room.

 Heating

The system heats up a room to the
temperature setpoint.

 Cooling

The system cools down a room to the
temperature setpoint.

 Fan

The system only controls the airflow
(airflow rate and airflow direction).

The system does NOT control the
temperature.

Additional info:

Outside  temperature.

  The  system's  cooling  or  heating  effect

decreases when the outside temperature is too high or too low.

Defrost operation.

 During heating operation, frost might occur on

the  outdoor  unit  and  decrease  the  heating  capacity.  In  that  case,
the  system  automatically  switches  to  defrosting  operation  to
remove  the  frost.  During  defrosting  operation,  hot  air  is  NOT
blown from the indoor unit.

5.2.1

To start/stop operation mode and to set
the temperature

: Operation mode = Automatic

: Operation mode = Drying

: Operation mode = Heating

: Operation mode = Cooling

: Operation mode = Fan only

: Shows the set temperature.

1

Start operation by pressing one of the following buttons.

Mode

Press

Result

Automatic operation

The operation lamp lights
up.

Cooling operation

Drying operation

Heating operation

Fan only operation

2

Press 

 or 

 on the 

 button one or more times to set the

temperature. You CANNOT adjust the temperature in 

drying

 or

fan only

 operation mode.

Cooling
operation

Heating
operation

Automatic
operation

Drying or fan
only operation

18~32°C

10~30°C

18~30°C

3

Press 

 to stop operation.

Result: 

The operation lamp goes off.

5.3

Airflow rate

INFORMATION

▪ When  using  drying  operation  mode,  you  CANNOT

adjust the airflow rate setting.

▪ The  airflow  rate  in  heating  mode  will  lower  to  avoid

generating  cold  airflow.  When  temperature  of  the
airflow  rise,  operation  will  continue  at  the  set  airflow
rate.

1

Press 

 to choose:

5 airflow rate levels, from "

" to "

"

Automatic airflow rate operation

Indoor unit quiet operation. When the airflow rate is

set to "

", the noise from the unit will be reduced.

INFORMATION

If the unit reaches the temperature setpoint:

▪ in cooling or automatic mode. Fan will stop operating.

▪ in heating mode. Fan will operate in low airflow rate.

5.3.1

To adjust the airflow rate

1

Press 

 to change the airflow setting as follows:

5.4

Airflow direction

When.

 Adjust the airflow direction as desired.

What.

  The  system  directs  the  airflow  differently,  depending  on  the

user  selection  (swinging  or  fixed  position).  It  does  so  by  moving
horizontal blades (flaps) or vertical blades (louvers).

Setting

Airflow direction

 Vertical automatic

swing

Moves up and down.

 Horizontal

automatic swing

Moves from side to side.

+

 3-D airflow

direction

Moves alternately up and down and
from side to side

[—]

Stays in a fixed position.

CAUTION

ALWAYS  use  the  wireless  remote  control  or  other  user
interface  (if  applicable)  to  adjust  the  position  of  the  flaps
and louvers. When the flaps and louvers are swinging and
you move them forcibly by hand, the mechanism will break.

Summary of Contents for FTXP50N2V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXP50N2V1B FTXP60N2V1B FTXP71N2V1B...

Page 2: ...the titanium apatite deodorising filter and the silver particle filter Ag ion filter 10 7 7 To replace the titanium apatite deodorising filter and the silver particle filter Ag ion filter 11 7 8 To cl...

Page 3: ...T operate the system when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals WARNING The refrigerant ins...

Page 4: ...ely safe non toxic and mildly flammable but it will generate toxic gas when it accidentally leaks into a room where combustible air from fan heaters gas cookers etc is present Always have qualified se...

Page 5: ...ear 1 Remove the back cover 2 Insert both batteries at once 3 Put the cover back 2 3 1 AAA LR03 4 2 To mount the wireless remote control holder c b a 2 a Wireless remote control b Screws field supply...

Page 6: ...by pressing one of the following buttons Mode Press Result Automatic operation The operation lamp lights up Cooling operation Drying operation Heating operation Fan only operation 2 Press or on the bu...

Page 7: ...5 1 To start stop Comfort airflow operation 1 Press to start Result The flap position will change is displayed on the LCD and the airflow rate is set to automatic Mode Position of flap Cooling Drying...

Page 8: ...ing disappear from the LCD and the timer lamp goes off 5 8 3 To combine OFF timer and ON timer 1 To set the timers refer to 5 8 1 To start stop OFF timer operation 4 8 and 5 8 2 To start stop ON timer...

Page 9: ...fire or the formation of a harmful gas Turn OFF any combustible heating devices ventilate the room and contact the dealer where you purchased the unit Do NOT use the unit until a service person confi...

Page 10: ...front panel with a soft cloth If it is difficult to remove stains use water or a neutral detergent 7 4 To open the front panel 1 Hold the front panel by the panel tabs on both sides and open it 7 5 T...

Page 11: ...fter several seasons of use This results in poor performance 8 Troubleshooting If one of the following malfunctions occur take the measures shown below and contact your dealer WARNING Stop operation a...

Page 12: ...3P511999 8Q 2022 06 Copyright 2022 Daikin Verantwortung f r Energie und Umwelt...

Reviews: