8 Troubleshooting

Operation manual

11

FTXP-N
Daikin room air conditioner
3P511999-8Q – 2022.06

a

Tab

2

Remove the dust from the filter with a vacuum cleaner.

3

Soak the filter for 10 to 15 minutes in warm water.

Note: 

 Do NOT remove the filter from the frame.

4

After washing, shake off remaining water and dry the filter in the
shade. Do NOT wring out the filter when removing water.

7.7

To replace the titanium apatite
deodorising filter and the silver
particle filter (Ag-ion filter)

INFORMATION

Replace the filter every 3 years.

1

Remove  the  filter  from  the  tabs  of  the  filter  frame  and  replace
the filter with a new one.

INFORMATION

▪ Do NOT throw away the filter frame, but use it again.

▪ Dispose of the old filter as non-flammable waste.

To  order  titanium  apatite  deodorising  filter  or  silver  particle  filters,
contact your dealer.

Item

Part number

Titanium deodorising filter

KAF970A46

Silver particle filter

KAF057A41

7.8

To close the front panel

1

Set the filters as they were.

2

Gently press the front panel at both sides and at the center until
it clicks.

7.9

To take following items into
account before a long idle period

1

Set the mode to 

fan only

 by pressing 

 button to dry the

inside of the unit.

2

After operation stops, turn the breaker OFF.

3

Clean the air filters and replace them in their original positions.

4

Remove the batteries from the wireless remote control.

INFORMATION

It  is  recommended  to  have  periodical  maintenance
performed  by  a  specialist.  For  specialist  maintenance,
contact  your  dealer.  Maintenance  costs  shall  be  borne  by
the customer.

In  certain  operating  conditions  the  inside  of  the  unit  may
get dirty after several seasons of use. This results in poor
performance.

8

Troubleshooting

If one of the following malfunctions occur, take the measures shown
below and contact your dealer.

WARNING

Stop  operation  and  shut  OFF  the  power  if  anything
unusual occurs (burning smells etc.).

Leaving  the  unit  running  under  such  circumstances  may
cause  breakage,  electrical  shock  or  fire.  Contact  your
dealer.

The system MUST be repaired by a qualified service person.

Malfunction

Measure

If a safety device such as a fuse, a
breaker or an earth leakage breaker
frequently actuates or the ON/OFF
switch does NOT properly work.

Turn OFF the main power
switch.

If water leaks from the unit.

Stop the operation.

The operation switch does NOT work
well.

Turn OFF the power
supply.

The operation lamp flashes and you can
check the error code by the wireless
remote control. To display the error
code see the user reference guide.

Notify your installer and
report the error code.

If  the  system  does  NOT  operate  properly  except  for  the  above
mentioned cases and none of the above mentioned malfunctions is
evident,  investigate  the  system  in  accordance  with  the  following
procedures.

INFORMATION

Refer  to  the  reference  guide  located  on 

https://

www.daikin.eu

  for  more  troubleshooting  tips.  Use  the

search function   to find your model.

If  after  checking  all  above  items,  it  is  impossible  to  fix  the  problem
yourself, contact your installer and state the symptoms, the complete
model name of the unit (with manufacturing number if possible) and
the installation date (possibly listed on the warranty card).

9

Disposal

NOTICE

Do  NOT  try  to  dismantle  the  system  yourself:  dismantling
of  the  system,  treatment  of  the  refrigerant,  oil  and  other
parts  MUST  comply  with  applicable  legislation.  Units
MUST  be  treated  at  a  specialised  treatment  facility  for
reuse, recycling and recovery.

Summary of Contents for FTXP50N2V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXP50N2V1B FTXP60N2V1B FTXP71N2V1B...

Page 2: ...the titanium apatite deodorising filter and the silver particle filter Ag ion filter 10 7 7 To replace the titanium apatite deodorising filter and the silver particle filter Ag ion filter 11 7 8 To cl...

Page 3: ...T operate the system when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals WARNING The refrigerant ins...

Page 4: ...ely safe non toxic and mildly flammable but it will generate toxic gas when it accidentally leaks into a room where combustible air from fan heaters gas cookers etc is present Always have qualified se...

Page 5: ...ear 1 Remove the back cover 2 Insert both batteries at once 3 Put the cover back 2 3 1 AAA LR03 4 2 To mount the wireless remote control holder c b a 2 a Wireless remote control b Screws field supply...

Page 6: ...by pressing one of the following buttons Mode Press Result Automatic operation The operation lamp lights up Cooling operation Drying operation Heating operation Fan only operation 2 Press or on the bu...

Page 7: ...5 1 To start stop Comfort airflow operation 1 Press to start Result The flap position will change is displayed on the LCD and the airflow rate is set to automatic Mode Position of flap Cooling Drying...

Page 8: ...ing disappear from the LCD and the timer lamp goes off 5 8 3 To combine OFF timer and ON timer 1 To set the timers refer to 5 8 1 To start stop OFF timer operation 4 8 and 5 8 2 To start stop ON timer...

Page 9: ...fire or the formation of a harmful gas Turn OFF any combustible heating devices ventilate the room and contact the dealer where you purchased the unit Do NOT use the unit until a service person confi...

Page 10: ...front panel with a soft cloth If it is difficult to remove stains use water or a neutral detergent 7 4 To open the front panel 1 Hold the front panel by the panel tabs on both sides and open it 7 5 T...

Page 11: ...fter several seasons of use This results in poor performance 8 Troubleshooting If one of the following malfunctions occur take the measures shown below and contact your dealer WARNING Stop operation a...

Page 12: ...3P511999 8Q 2022 06 Copyright 2022 Daikin Verantwortung f r Energie und Umwelt...

Reviews: