background image

3 About the system

Operation manual

4

FTXP-N

Daikin room air conditioner

3P511999-8Q – 2022.06

WARNING

Improper detergents or cleaning
procedure may cause damage on
plastic components or water leakage.
Splashed detergent on electric
components, such as motors, may
cause failure, smoke or ignition.

DANGER: RISK OF
ELECTROCUTION

Before cleaning, be sure to stop the
operation, turn the breaker OFF or pull
out the supply cord. Otherwise, an
electrical shock and injury may result.

WARNING

Stop operation and shut OFF the
power if anything unusual occurs
(burning smells etc.).

Leaving the unit running under such
circumstances may cause breakage,
electrical shock or fire. Contact your
dealer.

3

About the system

WARNING: MILDLY FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

NOTICE

Do  NOT  use  the  system  for  other  purposes.  In  order  to
avoid  any  quality  deterioration,  do  NOT  use  the  unit  for
cooling  precision  instruments,  food,  plants,  animals,  or
works of art.

3.1

Indoor unit

CAUTION

Do  NOT  insert  fingers,  rods  or  other  objects  into  the  air
inlet or outlet. When the fan is rotating at high speed, it will
cause injury.

INFORMATION

The sound pressure level is less than 70 dBA.

WARNING

▪ Do  NOT  modify,  disassemble,  remove,  reinstall  or

repair  the  unit  yourself  as  incorrect  dismantling  or
installation  may  cause  an  electrical  shock  or  fire.
Contact your dealer.

▪ In case of accidental refrigerant leaks, make sure there

are  no  naked  flames.  The  refrigerant  itself  is  entirely
safe,  non-toxic  and  mildly  flammable,  but  it  will
generate  toxic  gas  when  it  accidentally  leaks  into  a
room  where  combustible  air  from  fan  heaters,  gas
cookers,  etc.  is  present.  Always  have  qualified  service
personnel  confirm  that  the  point  of  leakage  has  been
repaired or corrected before resuming operation.

INFORMATION

The  following  figures  are  just  examples  and  may  NOT
completely match your system layout.

3.1.1

Indoor unit display

ON/OFF

a

b

c

d

a

Signal receiver

b

Operation lamp

c

Timer lamp

d

ON/OFF button

ON/OFF button

If the user interface is missing, you can use the ON/OFF button on
the  indoor  unit  to  start/stop  operation.  When  operation  is  started
using this button, the following settings are used:

▪ Operation mode = Automatic

▪ Temperature setting = 25°C

▪ Airflow rate = Automatic

3.2

About the user interface

Wireless remote control

INFORMATION

The  indoor  unit  is  delivered  with  the  wireless  remote
control  as  the  user  interface.  This  manual  describes  only
operation with this user interface. If another user interface
is  connected,  refer  to  the  operation  manual  of  the
connected user interface.

Direct  sunlight.

  Do  NOT  expose  the  wireless  remote  control  to

direct sunlight.

Dust.

  Dust  on  the  signal  transmitter  or  receiver  will  reduce

sensitivity. Wipe off dust with a soft cloth.

Fluorescent  lights.

  Signal  communication  might  be  disabled  if

fluorescent  lamps  are  in  the  room.  In  that  case,  contact  your
installer.

Other  appliances.

  If  the  wireless  remote  control  signals  operate

other  appliances,  move  the  other  appliances,  or  contact  your
installer.

Curtains.

 Make sure that curtains or other objects do NOT block

the signal between the unit and the wireless remote control.

Summary of Contents for FTXP50N2V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXP50N2V1B FTXP60N2V1B FTXP71N2V1B...

Page 2: ...the titanium apatite deodorising filter and the silver particle filter Ag ion filter 10 7 7 To replace the titanium apatite deodorising filter and the silver particle filter Ag ion filter 11 7 8 To cl...

Page 3: ...T operate the system when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals WARNING The refrigerant ins...

Page 4: ...ely safe non toxic and mildly flammable but it will generate toxic gas when it accidentally leaks into a room where combustible air from fan heaters gas cookers etc is present Always have qualified se...

Page 5: ...ear 1 Remove the back cover 2 Insert both batteries at once 3 Put the cover back 2 3 1 AAA LR03 4 2 To mount the wireless remote control holder c b a 2 a Wireless remote control b Screws field supply...

Page 6: ...by pressing one of the following buttons Mode Press Result Automatic operation The operation lamp lights up Cooling operation Drying operation Heating operation Fan only operation 2 Press or on the bu...

Page 7: ...5 1 To start stop Comfort airflow operation 1 Press to start Result The flap position will change is displayed on the LCD and the airflow rate is set to automatic Mode Position of flap Cooling Drying...

Page 8: ...ing disappear from the LCD and the timer lamp goes off 5 8 3 To combine OFF timer and ON timer 1 To set the timers refer to 5 8 1 To start stop OFF timer operation 4 8 and 5 8 2 To start stop ON timer...

Page 9: ...fire or the formation of a harmful gas Turn OFF any combustible heating devices ventilate the room and contact the dealer where you purchased the unit Do NOT use the unit until a service person confi...

Page 10: ...front panel with a soft cloth If it is difficult to remove stains use water or a neutral detergent 7 4 To open the front panel 1 Hold the front panel by the panel tabs on both sides and open it 7 5 T...

Page 11: ...fter several seasons of use This results in poor performance 8 Troubleshooting If one of the following malfunctions occur take the measures shown below and contact your dealer WARNING Stop operation a...

Page 12: ...3P511999 8Q 2022 06 Copyright 2022 Daikin Verantwortung f r Energie und Umwelt...