background image

5 Operation

Operation manual

7

FTXP20~35 ATXP20~35N5V1B9
R32 Split series
3P717028-5D – 2023.08

(b)

Condensation and water dripping might occur if the unit runs
outside its operation range.

5.2

When to use which feature

You can use the following table to determine which features to use:

Feature

Tasks

Basic features

 Operation modes and

temperature

To start/stop the system and to set the
temperature:

▪ Heat up or cool down a room.

▪ Blow air in a room without heating or

cooling.

▪ Decrease the humidity in a room.

▪ In  Automatic  mode,  automatically

select  an  appropriate  temperature
and operation mode.

 + 

 Airflow

direction

To adjust the airflow direction (swing or
fixed position).

 Airflow rate

To adjust the amount of air blown into
the room.

To run more quietly.

Advanced features

 Econo

To use the system when you are also
using other power-consuming
appliances.

To save energy.

 Comfort

To provide a comfortable airflow that
does NOT come in direct contact with
people.

 Powerful

To cool down or heat up the room
quickly.

 ON timer + 

OFF timer

To automatically turn ON or OFF the
system.

5.3

Operation mode and temperature
setpoint

When.

  Adjust  the  system  operation  mode  and  set  the  temperature

when you want to:

▪ Heat up or cool down a room

▪ Blow air in a room without heating or cooling

▪ Decrease the humidity in a room

What.

  The  system  operates  differently,  depending  on  the  user

selection.

Setting

Description

 Automatic

The system cools down or heats up a
room to the temperature setpoint. It
automatically switches between cooling
and heating if necessary.

 Drying

The system decreases the humidity in a
room.

 Heating

The system heats up a room to the
temperature setpoint.

 Cooling

The system cools down a room to the
temperature setpoint.

 Fan

The system only controls the airflow
(airflow rate and airflow direction).

The system does NOT control the
temperature.

Additional info:

Outside  temperature.

  The  system's  cooling  or  heating  effect

decreases when the outside temperature is too high or too low.

Defrost operation.

 During heating operation, frost might occur on

the  outdoor  unit  and  decrease  the  heating  capacity.  In  that  case,
the  system  automatically  switches  to  defrosting  operation  to
remove  the  frost.  During  defrosting  operation,  hot  air  is  NOT
blown from the indoor unit.

5.3.1

To start/stop operation mode and to set
the temperature

: Operation mode = Automatic

: Operation mode = Drying

: Operation mode = Heating

: Operation mode = Cooling

: Operation mode = Fan only

: Shows the set temperature.

1

Start operation by pressing one of the following buttons.

Mode

Press

Result

Automatic operation

The operation lamp lights
up.

Cooling operation

Drying operation

Heating operation

Fan only operation

2

Press 

 or 

 on the 

 button one or more times to set the

temperature. You CANNOT adjust the temperature in 

drying

 or

fan only

 operation mode.

Cooling
operation

Heating
operation

Automatic
operation

Drying or fan
only operation

18~32°C

10~30°C

18~30°C

3

Press 

 to stop operation.

Result: 

The operation lamp goes off.

5.3.2

Airflow rate

1

Press 

 to choose:

5 airflow rate levels, from "

" to "

"

Automatic airflow rate operation

Indoor unit quiet operation. When the airflow rate is

set to "

", the noise from the unit will be reduced.

INFORMATION

▪ If  the  unit  reaches  the  temperature  setpoint  in  cooling

or heating mode, the fan will stop operating.

▪ When  using  drying  operation  mode,  you  CANNOT

adjust the airflow rate setting.

To adjust the airflow rate

1

Press 

 to change the airflow setting as follows:

Summary of Contents for FTXP20N5V1B9

Page 1: ...Operation manual R32 Split series English Operation manual R32 Split series FTXP20N5V1B9 FTXP25N5V1B9 FTXP35N5V1B9 ATXP20N5V1B9 ATXP25N5V1B9 ATXP35N5V1B9...

Page 2: ...1 2 Symptom A blowing sound is heard 13 8 1 3 Symptom A ticking sound is heard 14 8 1 4 Symptom A whistling sound is heard 14 8 1 5 Symptom A clicking sound during operation or idle time is heard 14...

Page 3: ...contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialised treatment facility for reuse By ensuring waste batteri...

Page 4: ...ecified in the General safety precaution DANGER RISK OF ELECTROCUTION To clean the air conditioner or air filter be sure to stop operation and turn all power supplies OFF Otherwise an electrical shock...

Page 5: ...peration mode Automatic Temperature setting 25 C Airflow rate Automatic 3 2 About the user interface Wireless remote control INFORMATION The indoor unit is delivered with the wireless remote control a...

Page 6: ...anges Long beep Operation stops 4 Before operation 4 1 To mount the wireless remote control holder c b a 2 a Wireless remote control b Screws field supply c Wireless remote control holder 1 Choose a p...

Page 7: ...a room to the temperature setpoint Cooling The system cools down a room to the temperature setpoint Fan The system only controls the airflow airflow rate and airflow direction The system does NOT cont...

Page 8: ...ystem automatically sets the fixed airflow position upward in Cooling and downward in Heating operation mode Cooling operation mode Heating operation mode INFORMATION Powerful and Comfort airflow oper...

Page 9: ...temperature setting 0 5 C up in cooling 2 0 C down in heating to prevent excessive cooling heating and ensure a comfortable sleeping temperature Use this feature if the unit is operating and you want...

Page 10: ...LED then wireless LAN is blinks blinks not connected If operation LED and timer LED then wireless LAN is is off blinks in 0 5 second interval running and ready to connect to the home network via WPS...

Page 11: ...alculate the quantity in CO2 equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Contact your installer for more information NOTICE Maintenance MUST be done by an author...

Page 12: ...stains use water or a neutral detergent 7 4 To clean the air filters 1 Push the tab at the centre of each air filter then pull it down 2 Pull out the air filters 1 2 3 Remove the titanium apatite deo...

Page 13: ...ARNING Stop operation and shut OFF the power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electrical shock or fire Contact your de...

Page 14: ...wireless remote control If the unit runs into a problem you can identify the fault by checking the error code by the wireless remote control It is important to understand the problem and take measures...

Page 15: ...7028 5D 2023 08 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units M...

Page 16: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P717028 5D 2023 08 Copyright 20...

Reviews: