background image

5 Operation

Operation manual

10

FTXP20~35 ATXP20~35N5V1B9

R32 Split series

3P717028-5D – 2023.08

5.4.2

To install the ONECTA app

1

Go  to  Google  Play  (for  Android  devices)  or  the  App  Store  (for
iOS devices) and search for "ONECTA".

2

Follow the directions on the screen to install the ONECTA app.

INFORMATION

Scan  the  QR  code  to  download  and  install  the  ONECTA
app 

on 

your 

mobile 

phone 

or 

tablet:

5.4.3

To set the wireless connection

There  are  two  options  to  connect  the  wireless  adapter  with  your
smart device.

Connect the wireless LAN to your smart device directly.

Connect the wireless LAN to your home network. 

The wireless

LAN  will  communicate  with  your  smart  device  in  your  home
network using a modem, router or a similar device.

For more information and FAQ refer to 

app.daikineurope.com

.

1

Stop operation before setting the wireless connection.

2

Use  the  wireless  remote  control  to  select  the  wireless  LAN
setting menu.

Note: 

During  setting,  always  aim  the  wireless  remote  control  at  the

infrared signal receiver on the unit.

Menu

Description

Connection status check

WPS connection setting

Reset to factory default

Wireless LAN OFF

To confirm the wireless LAN connection status

1

On  home  screen  menu,  press  and  hold 

  for  at  least

5 seconds while the unit is not operating.

Result: 

The  SP  (wireless  connection  setting  menu)  appears. 

is blinking.

(5 sec.) 

2

Press 

 to confirm the selection.

Result: 

 is blinking.

3

Check the operation and timer LEDs on the indoor unit display.

ON/OFF

a

b

a

Operation LED

b

Timer LED

If operation
LED…

…and timer LED… …then wireless LAN is…

blinks

blinks

not connected

If operation
LED…

…and timer LED… …then wireless LAN is…

is off

blinks in 0.5 second
interval

running and ready to connect
to the home network via WPS
button on the router.

is off

blinks in 1 second
interval

▪ connected  to  the  home

network via SSID + KEY.

or

▪ connected  to  the  home

network via WPS button on
the router.

4

Press 

 to exit the menu.

Result: 

The display will return to the default screen.

To connect the wireless LAN to your home
network

The wireless adapter can be connected to your home network using
the:

▪ WPS button (Wi-Fi Protected Setup) on the router (if present),

▪ The  SSID  (Service  Set  Identifier)  and  the  KEY  (password)  -

located on the unit.

To connect using the WPS button

To reset the connection setting to the factory
default

Reset the connection setting to the factory default in case you want
to:

▪ disconnect  the  wireless  LAN  and  the  communication  device  (e.g.

router) or smart device,

▪ repeat the setting if the connection was unsuccessful.

1

On home screen menu, hold 

 for at least 5 seconds while

the unit is not operating.

Result: 

The SP menu   appears.   is blinking.

2

Change to the SP menu   by pressing  twice or  repeatedly.

(5 sec.) 

3

Hold 

 for at least 2 seconds to confirm the selection.

Result: 

 is blinking. The operation and timer LEDs are blinking

at  the  same  time  in  1  s  interval.  The  setting  is  reset  to  the
factory default.

4

Press 

 to exit the menu.

Result: 

The display will return to the default screen.

To turn off the wireless LAN connection

If you want to turn off the wireless connection function:

1

On  home  screen  menu,  press 

  for  at  least  5  seconds

while the unit is not operating.

Result: 

The SP menu   appears.   is blinking.

2

Change to the SP menu 

 by pressing  once or  repeatedly.

Summary of Contents for FTXP20N5V1B9

Page 1: ...Operation manual R32 Split series English Operation manual R32 Split series FTXP20N5V1B9 FTXP25N5V1B9 FTXP35N5V1B9 ATXP20N5V1B9 ATXP25N5V1B9 ATXP35N5V1B9...

Page 2: ...1 2 Symptom A blowing sound is heard 13 8 1 3 Symptom A ticking sound is heard 14 8 1 4 Symptom A whistling sound is heard 14 8 1 5 Symptom A clicking sound during operation or idle time is heard 14...

Page 3: ...contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialised treatment facility for reuse By ensuring waste batteri...

Page 4: ...ecified in the General safety precaution DANGER RISK OF ELECTROCUTION To clean the air conditioner or air filter be sure to stop operation and turn all power supplies OFF Otherwise an electrical shock...

Page 5: ...peration mode Automatic Temperature setting 25 C Airflow rate Automatic 3 2 About the user interface Wireless remote control INFORMATION The indoor unit is delivered with the wireless remote control a...

Page 6: ...anges Long beep Operation stops 4 Before operation 4 1 To mount the wireless remote control holder c b a 2 a Wireless remote control b Screws field supply c Wireless remote control holder 1 Choose a p...

Page 7: ...a room to the temperature setpoint Cooling The system cools down a room to the temperature setpoint Fan The system only controls the airflow airflow rate and airflow direction The system does NOT cont...

Page 8: ...ystem automatically sets the fixed airflow position upward in Cooling and downward in Heating operation mode Cooling operation mode Heating operation mode INFORMATION Powerful and Comfort airflow oper...

Page 9: ...temperature setting 0 5 C up in cooling 2 0 C down in heating to prevent excessive cooling heating and ensure a comfortable sleeping temperature Use this feature if the unit is operating and you want...

Page 10: ...LED then wireless LAN is blinks blinks not connected If operation LED and timer LED then wireless LAN is is off blinks in 0 5 second interval running and ready to connect to the home network via WPS...

Page 11: ...alculate the quantity in CO2 equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Contact your installer for more information NOTICE Maintenance MUST be done by an author...

Page 12: ...stains use water or a neutral detergent 7 4 To clean the air filters 1 Push the tab at the centre of each air filter then pull it down 2 Pull out the air filters 1 2 3 Remove the titanium apatite deo...

Page 13: ...ARNING Stop operation and shut OFF the power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electrical shock or fire Contact your de...

Page 14: ...wireless remote control If the unit runs into a problem you can identify the fault by checking the error code by the wireless remote control It is important to understand the problem and take measures...

Page 15: ...7028 5D 2023 08 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units M...

Page 16: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P717028 5D 2023 08 Copyright 20...

Reviews: