background image

3 About the system

Operation manual

4

FTXP20~35 ATXP20~35N5V1B9

R32 Split series

3P717028-5D – 2023.08

the unit, and endanger the health of
people who are hypersensitive to
chemicals.

WARNING

▪ The refrigerant inside the unit is

mildly flammable, but normally does
NOT leak. If the refrigerant leaks in
the room and comes in contact with
fire from a burner, a heater, or a
cooker, this may result in fire, or the
formation of a harmful gas.

▪ Turn OFF any combustible heating

devices, ventilate the room, and
contact the dealer where you
purchased the unit.

▪ Do NOT use the unit until a service

person confirms that the part from
which the refrigerant leaked has been
repaired.

WARNING

▪ Do NOT pierce or burn refrigerant

cycle parts.

▪ Do NOT use cleaning materials or

means to accelerate the defrosting
process other than those
recommended by the manufacturer.

▪ Be aware that the refrigerant inside

the system is odourless.

WARNING

The appliance shall be stored so as to
prevent mechanical damage and in a
well-ventilated room without
continuously operating ignition sources
(e.g. open flames, an operating gas
appliance, or an operating electric
heater). The room size shall be as
specified in the General safety
precaution.

DANGER: RISK OF
ELECTROCUTION

To clean the air conditioner or air filter,
be sure to stop operation and turn all
power supplies OFF. Otherwise, an
electrical shock and injury may result.

CAUTION

After a long use, check the unit stand
and fitting for damage. If damaged, the
unit may fall and result in injury.

WARNING

Be careful with ladders when working
in high places.

WARNING

Improper detergents or cleaning
procedure may cause damage on
plastic components or water leakage.
Splashed detergent on electric
components, such as motors, may
cause failure, smoke or ignition.

DANGER: RISK OF
ELECTROCUTION

Before cleaning, be sure to stop the
operation, turn the breaker OFF or pull
out the supply cord. Otherwise, an
electrical shock and injury may result.

WARNING

Stop operation and shut OFF the
power if anything unusual occurs
(burning smells etc.).

Leaving the unit running under such
circumstances may cause breakage,
electrical shock or fire. Contact your
dealer.

WARNING: MILDLY FLAMMABLE
MATERIAL

The refrigerant inside this unit is
mildly flammable.

3

About the system

WARNING: MILDLY FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

NOTICE

Do  NOT  use  the  system  for  other  purposes.  In  order  to
avoid  any  quality  deterioration,  do  NOT  use  the  unit  for
cooling  precision  instruments,  food,  plants,  animals,  or
works of art.

Summary of Contents for FTXP20N5V1B9

Page 1: ...Operation manual R32 Split series English Operation manual R32 Split series FTXP20N5V1B9 FTXP25N5V1B9 FTXP35N5V1B9 ATXP20N5V1B9 ATXP25N5V1B9 ATXP35N5V1B9...

Page 2: ...1 2 Symptom A blowing sound is heard 13 8 1 3 Symptom A ticking sound is heard 14 8 1 4 Symptom A whistling sound is heard 14 8 1 5 Symptom A clicking sound during operation or idle time is heard 14...

Page 3: ...contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialised treatment facility for reuse By ensuring waste batteri...

Page 4: ...ecified in the General safety precaution DANGER RISK OF ELECTROCUTION To clean the air conditioner or air filter be sure to stop operation and turn all power supplies OFF Otherwise an electrical shock...

Page 5: ...peration mode Automatic Temperature setting 25 C Airflow rate Automatic 3 2 About the user interface Wireless remote control INFORMATION The indoor unit is delivered with the wireless remote control a...

Page 6: ...anges Long beep Operation stops 4 Before operation 4 1 To mount the wireless remote control holder c b a 2 a Wireless remote control b Screws field supply c Wireless remote control holder 1 Choose a p...

Page 7: ...a room to the temperature setpoint Cooling The system cools down a room to the temperature setpoint Fan The system only controls the airflow airflow rate and airflow direction The system does NOT cont...

Page 8: ...ystem automatically sets the fixed airflow position upward in Cooling and downward in Heating operation mode Cooling operation mode Heating operation mode INFORMATION Powerful and Comfort airflow oper...

Page 9: ...temperature setting 0 5 C up in cooling 2 0 C down in heating to prevent excessive cooling heating and ensure a comfortable sleeping temperature Use this feature if the unit is operating and you want...

Page 10: ...LED then wireless LAN is blinks blinks not connected If operation LED and timer LED then wireless LAN is is off blinks in 0 5 second interval running and ready to connect to the home network via WPS...

Page 11: ...alculate the quantity in CO2 equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Contact your installer for more information NOTICE Maintenance MUST be done by an author...

Page 12: ...stains use water or a neutral detergent 7 4 To clean the air filters 1 Push the tab at the centre of each air filter then pull it down 2 Pull out the air filters 1 2 3 Remove the titanium apatite deo...

Page 13: ...ARNING Stop operation and shut OFF the power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electrical shock or fire Contact your de...

Page 14: ...wireless remote control If the unit runs into a problem you can identify the fault by checking the error code by the wireless remote control It is important to understand the problem and take measures...

Page 15: ...7028 5D 2023 08 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units M...

Page 16: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P717028 5D 2023 08 Copyright 20...