background image

5.  Energy saving and optimum operation

 INFORMATION

• 

Even if the unit is turned OFF, it consumes electricity.

• 

When the power turns back on after a power break, the 
previously selected mode will be resumed.

 CAUTION

NEVER expose little children, plants or animals directly to the 

airflow.

 WARNING

Do NOT place objects below the indoor and/or outdoor unit that 
may get wet. Otherwise condensation on the unit or refrigerant 

pipes, air filter dirt or drain blockage may cause dripping, and 

objects under the unit may get dirty or damaged.

 NOTICE

Do NOT use the system for other purposes. In order to avoid 
any quality deterioration, do NOT use the unit for cooling 
precision instruments, food, plants, animals, or works of art.

 WARNING

Do NOT place a flammable spray bottle near the air conditioner 
and do NOT use sprays. Doing so may result in a fire.

Observe the following precautions to ensure the system 
operates properly.

• 

Prevent direct sunlight from entering a room during cooling 
operation by using curtains or blinds.

• 

Ventilate often. Extended use requires special attention to 
ventilation.

• 

Keep doors and windows closed. If the doors and windows 

remain open, air will flow out of your room causing a decrease 

in the cooling or heating effect.

• 

Be careful NOT to cool or heat too much. To save energy, keep 
the temperature setting at a moderate level.

• 

NEVER place objects near the air inlet or the air outlet of the unit. 
Doing so may cause a reduced heating/cooling effect or stop 
operation.

• 

Turn off the main power supply switch to the unit when the 
unit is NOT used for longer periods of time. If the main power 
supply switch is on, the unit consumes electricity. Before 
restarting the unit, turn on the main power supply switch 6 
hours before operation to ensure smooth running.

• 

Condensation may form if the humidity is above 80% or if the 

drain outlet gets blocked.

• 

Adjust the room temperature properly for a comfortable 
environment. Avoid excessive heating or cooling. Notice that 
it may take some time for the room temperature to reach the 
set temperature. Consider using the timer setting options.

• 

Adjust the airflow direction to avoid cool air from gathering on 
the floor or warm air against the ceiling. (Up during cooling or 

dry operation to the ceiling and down during heating operation.)

• 

Avoid direct airflow to room inhabitants.

• 

Operate the system within the recommended temperature range 
(26~28°C for cooling and 20~24°C for heating) to save energy.

6.  Maintenance and service

6-1 

Overview: Maintenance and service

The installer has to perform yearly maintenance.

 WARNING

• 

The refrigerant inside the unit is mildly flammable, but normally 

does NOT leak. If the refrigerant leaks in the room and comes 

in contact with fire from a burner, a heater, or a cooker, this 
may result in fire, or the formation of a harmful gas.

• 

Turn off any combustible heating devices, ventilate the room, 
and contact the dealer where you purchased the unit.

• 

Do NOT use the unit until a service person confirms that the 

part from which the refrigerant leaked has been repaired.

• 

Do NOT pierce or burn refrigerant cycle parts.

• 

Do NOT use cleaning materials or means to accelerate the 
defrosting process other than those recommended by the 
manufacturer.

• 

Be aware that the refrigerant inside the system is odourless.

• 

The appliance shall be stored in a room without continuously 

operating ignition sources (example: open flames, an 

operating gas appliance or an operating electric heater).

 16

01_EN_3P705032-1.indd   16

30/08/2022   10:20:10 am

Summary of Contents for FTXJ25T2VMAW

Page 1: ...und comfort Enjoy year round comfort Enjoy year round comfort DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXJ25T2VMAW FTXJ35T2VMAW FTXJ50T2VMAW FTXJ60T2VMAW FTXJ25T2VMAK FTXJ35T2VMAK FTXJ50T2...

Page 2: ...the front panel 17 6 5 About the air filters 17 6 6 To clean the air filters 18 6 7 To clean the titanium apatite deodorising filter 18 6 8 To close the front panel 18 6 9 To remove the front panel 19...

Page 3: ...urposes other than those for which it is intended Do not use the air conditioner for cooling precision instruments food plants animals or works of art as this may adversely affect the performance qual...

Page 4: ...lid g Intelligent eye sensor h Display i Room temperature and humidity sensor j ON OFF button and operation lamp green k Signal receiver l Timer lamp orange m Intelligent eye lamp green n Wireless ada...

Page 5: ...ode Automatic Operation mode Drying Operation mode Heating Operation mode Cooling Operation mode Fan only Powerful operation is active Econo operation is active Outdoor unit quiet operation is active...

Page 6: ...kage rupturing or heating Do not damage or peel off labels on the batteries 1 Slide the front cover to take it off 2 Insert 2 dry batteries AAA LR03 alkaline 3 Replace the front cover 2 3 1 Grip both...

Page 7: ...avoid direct airflow to walls 1 Press for at least 2 seconds Result The menu appears on the display 2 Press or to change the menu to Result The menu appears on the display blinks 3 Press to select th...

Page 8: ...r cooling Decrease the humidity in a room What The system operates differently depending on the user selection Setting Description Automatic The system cools down or heats up a room to the temperature...

Page 9: ...g a b a Flap range in cooling or drying operation b Flap range in heating or fan only operation To adjust vertical airflow direction 1 Press Result appears on the LCD The flaps horizontal blades will...

Page 10: ...default screen after 60 seconds To return to the default screen sooner press twice Intelligent eye operation The system detects movement in the room and automatically adjusts the airflow direction and...

Page 11: ...ing the rotation speed of the compressor If power consumption is already low Econo operation will NOT further reduce power consumption Outdoor unit quiet operation Use Outdoor unit quiet operation whe...

Page 12: ...esult and disappear from the LCD and the timer lamp goes off and the day of the week are displayed on the LCD INFORMATION When you set the ON OFF timer the time setting is stored in the memory The mem...

Page 13: ...N Weekly timer and ON OFF timer operation CANNOT be used at the same time The ON OFF timer operation takes priority Weekly timer will be in standby disappears from the LCD When the ON OFF timer is com...

Page 14: ...ll reservations are set to your needs 1 Press Result The day of the week and the reservation number of the current day are displayed 2 Press or to select the day of the week and reservation number to...

Page 15: ...bile Controller application 1 Open Google Play for appliances using Android App Store for appliances using iOS 2 Search for Daikin Mobile Controller 3 Follow the directions on the screen to install 4...

Page 16: ...smartphone to the home network To reset the connection setting to the factory default Reset the connection setting to the factory default in case you want to switch between the WPS and the AP connect...

Page 17: ...icity Before restarting the unit turn on the main power supply switch 6 hours before operation to ensure smooth running Condensation may form if the humidity is above 80 or if the drain outlet gets bl...

Page 18: ...LECTROCUTION Before cleaning be sure to stop the operation turn the circuit breaker off or pull out the supply cord Otherwise an electric shock and injury may result 1 Clean with a soft cloth If it is...

Page 19: ...FORMATION Clean the filter with water every 6 months 1 Remove the dust from the filter with a vacuum cleaner INFORMATION Replace the filter every 3 years Dispose of the old filter as non flammable was...

Page 20: ...ialist For specialist maintenance contact your dealer Maintenance costs shall be borne by the user In certain operating conditions the inside of the unit may get dirty after several seasons of use Thi...

Page 21: ...stem operates but heating is insufficient air is NOT blown from the unit To prevent the release of cold air air does not come out directly after operation is started Please wait 1 to 4 minutes If a fl...

Page 22: ...anel correct their positions at the beginning or end of operation or while operation is stopped It is the sound of the flaps louvres or front panel moving 7 1 9 Symptom White mist comes out of a unit...

Page 23: ...dmobile index html for more information and FAQ Problem Measure Connection to the WLAN adapter is not possible none of the LEDs are blinking Try operating the unit with the remote controller Check if...

Page 24: ...3P705032 1 M22N087 2210 HT The two dimensional bar code is a manufacturing code 00_CV_3P705032 1 indd 2 31 Aug 22 10 24 12 AM...