Malfunction

Measure

If the system does 
NOT operate at all.

• 

Check if there is no power failure. 
Wait until power is restored. If a 
power failure occurs during operation, 
the system automatically restarts 
immediately after power is restored.

• 

Check if the front panel is opened 
during operation. Stop operation 
and restart the indoor unit using the 
remote controller.

• 

Check if no fuse has blown or circuit 
breaker is activated. Change the fuse or 
reset the circuit breaker if necessary.

• 

Check the batteries of the remote 
controller.

• 

Check the timer setting.

The system 
suddenly stops 
operating.

• 

Check if the air inlet or outlet of the 
outdoor or indoor unit is NOT blocked 
by obstacles. Remove any obstacles 

and make sure the air can flow freely.

• 

The air conditioner may stop operating 

after sudden large voltage fluctuations 

to protect the system. It automatically 
resumes operation after about 3 minutes.

The flaps do NOT start 

to swing immediately.

The indoor unit is adjusting the position of 

the flaps. The flaps will start moving soon.

Operation does NOT 
start soon.

In case the ON/OFF button was pressed 
right after operation was stopped or if the 
mode was changed. Operation will start 
after 3 minutes to protect the system.

The system 
operates,but 
cooling or heating is 

insufficient.

• 

Check the airflow rate setting. Refer to 
“4-3-2 Airflow rate” on page 8.

• 

Check the temperature setting. Refer to  

“4-3-1 To start/stop operation and to set 
the temperature” on page 7.

• 

Check if the airflow direction setting 
is appropriate. Refer to “4-3-3 Airflow 
direction” on page 8.

• 

Check if the air inlet or outlet of the 
outdoor or indoor unit is NOT blocked 
by obstacles. Remove any obstacles 

and make sure the air can flow freely.

• 

Check if the air filters are clogged. 
Clean the air filters. See “6 
Maintenance and service” on page 16.

• 

Check for open doors or windows. 
Close doors and windows to prevent 
wind from coming in.

• 

Check if the position setting is 
appropriate for the installed position 

of the unit. Refer to “3-6 To change 
indoor unit position setting” on page 6.

• 

Check if the unit is operating without 

the front panel raised. Refer to “2-1 
Indoor unit” on page 3.

• 

Check if the unit operates in Econo or 
Outdoor unit quiet operation. Refer to 

“4-3-6 Econo and Outdoor unit quiet 
operation” on page 10.

• 

Check if there is any furniture directly 
under or next to the indoor unit. Move 
the furniture.

Malfunction

Measure

The system 
operates, but 

heating is insufficient 

(air is NOT blown 
from the unit).

• 

To prevent the release of cold air, 
air does not come out directly after 
operation is started. Please wait 1 to 
4 minutes.

• 

If a flowing sound is heard, the 

outdoor unit may be in defrost 
operation. Wait for about 4 to 12 
minutes.

The front panel does 
NOT open.

Check for the obstacles and try to open the 
front panel using the remote controller. Refer 

to “6-4 To open the front panel” on page 17.

The ON/OFF timer 
does NOT operate 
according to the 
settings.

• 

Check if the Weekly timer and ON/
OFF timer are set to the same time. 
Change or deactivate the setting. 

Refer to “4-5 OFF/ON timer operation” 
on page 11 and “4-6 Weekly timer 
operation” on page 12.

• 

Check if the clock and the day of the 

week are set correctly. Refer to “3-3 
Clock” on page 5.

Heating operation 
CANNOT be 
selected.

Check if the remote controller's jumper 
J8 has NOT been cut.

J8

An abnormal 
function happens 
during operation.

The air conditioner may malfunction 
because of lightning or radio waves. Turn 
the circuit breaker OFF and back ON.

The unit does NOT 
receive signals 
from the remote 
controller.

• 

Check the batteries of the remote 

controller. Refer to “3-2 To insert the 
batteries” on page 5.

• 

Make sure that the transmitter is NOT 
exposed to direct sunlight.

• 

Check if there are any electronic 

starter type fluorescent lamps in the 

room. Contact your dealer.

The remote 
controller display is 
blank.

Replace the batteries of the remote 
controller.

An error code is 
displayed on the 
remote controller.

Consult your local dealer. Refer to 

“7-2 Solving problems based on error 
codes” on page 21 for a detailed list of 

error codes.

Other electric 
appliances start to 
operate.

If the remote controller signals operate 
other electric appliances, move the other 
appliances away, and contact your dealer.

Drops of water form 
on the front panel

Check if the unit is operating without the 

front panel raised. Refer to “2-1 Indoor 
unit” on page 3.

The LCD is blinking 
and the remote 
controller cannot be 
operated.

Battery power has run out. Replace both 

batteries at the same time with new size 

AAA.LR03 (alkaline) batteries. Leaving 
exhausted batteries in the remote 
controller can result in injury due to 
battery leakage, rupturing or heating, or 
lead to equipment failure.(Even when the 
LCD is blinking, 

 remains functional.)

Unable to use the 
remote controller 
after exchanging the 
batteries

Remove the batteries for approximately  
1 minute, or remove the batteries and 
press any button for approximately 15 
seconds. This may improve conditions.

 20

01_EN_3P705032-1.indd   20

30/08/2022   10:20:13 am

Summary of Contents for FTXJ25T2VMAW

Page 1: ...und comfort Enjoy year round comfort Enjoy year round comfort DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXJ25T2VMAW FTXJ35T2VMAW FTXJ50T2VMAW FTXJ60T2VMAW FTXJ25T2VMAK FTXJ35T2VMAK FTXJ50T2...

Page 2: ...the front panel 17 6 5 About the air filters 17 6 6 To clean the air filters 18 6 7 To clean the titanium apatite deodorising filter 18 6 8 To close the front panel 18 6 9 To remove the front panel 19...

Page 3: ...urposes other than those for which it is intended Do not use the air conditioner for cooling precision instruments food plants animals or works of art as this may adversely affect the performance qual...

Page 4: ...lid g Intelligent eye sensor h Display i Room temperature and humidity sensor j ON OFF button and operation lamp green k Signal receiver l Timer lamp orange m Intelligent eye lamp green n Wireless ada...

Page 5: ...ode Automatic Operation mode Drying Operation mode Heating Operation mode Cooling Operation mode Fan only Powerful operation is active Econo operation is active Outdoor unit quiet operation is active...

Page 6: ...kage rupturing or heating Do not damage or peel off labels on the batteries 1 Slide the front cover to take it off 2 Insert 2 dry batteries AAA LR03 alkaline 3 Replace the front cover 2 3 1 Grip both...

Page 7: ...avoid direct airflow to walls 1 Press for at least 2 seconds Result The menu appears on the display 2 Press or to change the menu to Result The menu appears on the display blinks 3 Press to select th...

Page 8: ...r cooling Decrease the humidity in a room What The system operates differently depending on the user selection Setting Description Automatic The system cools down or heats up a room to the temperature...

Page 9: ...g a b a Flap range in cooling or drying operation b Flap range in heating or fan only operation To adjust vertical airflow direction 1 Press Result appears on the LCD The flaps horizontal blades will...

Page 10: ...default screen after 60 seconds To return to the default screen sooner press twice Intelligent eye operation The system detects movement in the room and automatically adjusts the airflow direction and...

Page 11: ...ing the rotation speed of the compressor If power consumption is already low Econo operation will NOT further reduce power consumption Outdoor unit quiet operation Use Outdoor unit quiet operation whe...

Page 12: ...esult and disappear from the LCD and the timer lamp goes off and the day of the week are displayed on the LCD INFORMATION When you set the ON OFF timer the time setting is stored in the memory The mem...

Page 13: ...N Weekly timer and ON OFF timer operation CANNOT be used at the same time The ON OFF timer operation takes priority Weekly timer will be in standby disappears from the LCD When the ON OFF timer is com...

Page 14: ...ll reservations are set to your needs 1 Press Result The day of the week and the reservation number of the current day are displayed 2 Press or to select the day of the week and reservation number to...

Page 15: ...bile Controller application 1 Open Google Play for appliances using Android App Store for appliances using iOS 2 Search for Daikin Mobile Controller 3 Follow the directions on the screen to install 4...

Page 16: ...smartphone to the home network To reset the connection setting to the factory default Reset the connection setting to the factory default in case you want to switch between the WPS and the AP connect...

Page 17: ...icity Before restarting the unit turn on the main power supply switch 6 hours before operation to ensure smooth running Condensation may form if the humidity is above 80 or if the drain outlet gets bl...

Page 18: ...LECTROCUTION Before cleaning be sure to stop the operation turn the circuit breaker off or pull out the supply cord Otherwise an electric shock and injury may result 1 Clean with a soft cloth If it is...

Page 19: ...FORMATION Clean the filter with water every 6 months 1 Remove the dust from the filter with a vacuum cleaner INFORMATION Replace the filter every 3 years Dispose of the old filter as non flammable was...

Page 20: ...ialist For specialist maintenance contact your dealer Maintenance costs shall be borne by the user In certain operating conditions the inside of the unit may get dirty after several seasons of use Thi...

Page 21: ...stem operates but heating is insufficient air is NOT blown from the unit To prevent the release of cold air air does not come out directly after operation is started Please wait 1 to 4 minutes If a fl...

Page 22: ...anel correct their positions at the beginning or end of operation or while operation is stopped It is the sound of the flaps louvres or front panel moving 7 1 9 Symptom White mist comes out of a unit...

Page 23: ...dmobile index html for more information and FAQ Problem Measure Connection to the WLAN adapter is not possible none of the LEDs are blinking Try operating the unit with the remote controller Check if...

Page 24: ...3P705032 1 M22N087 2210 HT The two dimensional bar code is a manufacturing code 00_CV_3P705032 1 indd 2 31 Aug 22 10 24 12 AM...

Reviews: