background image

3

2

• Split - Sky Air • FTXJ-MS, FTXJ-MW

3

• Indoor Unit • FTXJ-MS, FTXJ-MW

2

Specifications

2-1 Technical Specifications

FTXJ20MS

FTXJ25MS

FTXJ35MS

FTXJ50MS FTXJ20MW FTXJ25MW FTXJ35MW FTXJ50MW

Power input - 50Hz

Cooling

Nom.

kW

0.023

0.033

0.023

0.033

Heating

Nom.

kW

0.031

0.033

0.042

0.043

0.031

0.033

0.042

0.043

Casing

Colour

Silver

White

Dimensions

Unit

Height/Width/

Depth

mm

303/998/212

Packed unit

Height/Width/

Depth

mm

322/1,101/389

Weight

Unit

kg

12

Packed unit

kg

16

Packing

Weight

kg

4

Heat exchanger

Length

mm

610

Rows

Quantity

2

Fin pitch

mm

1.2

Stages

Quantity

18

Tube type

Ø6,35 Hi-XB

Fin

Type

Multi slit fin

Air filter

Type

Removable / washable / mildew proof

Fan

Type

Cross flow fan

Air flow rate

Cooling High

m³/min

8.9

10.9

8.9

10.9

cfm

313

385

313

385

Nom.

m³/min

6.6

7.8

8.9

6.6

7.8

8.9

cfm

234

276

313

234

276

313

Low

m³/min

4.4

4.8

6.8

4.4

4.8

6.8

cfm

155

168

239

155

168

239

Silent 

operati

on

m³/min

2.6

2.9

3.6

2.6

2.9

3.6

cfm

91

102

128

91

102

128

Heating High

m³/min

10.2

11.0

12.4

12.6

10.2

11.0

12.4

12.6

cfm

361

388

438

446

361

388

438

446

Nom.

m³/min

8.4

8.6

9.6

10.5

8.4

8.6

9.6

10.5

cfm

298

303

340

372

298

303

340

372

Low

m³/min

6.3

6.9

8.1

6.3

6.9

8.1

cfm

223

245

284

223

245

284

Silent 

operati

on

m³/min

3.8

4.1

5.0

3.8

4.1

5.0

cfm

133

144

176

133

144

176

Fan motor

Model

KFD-280-40-8G1

Speed

Steps

5 + silent, + auto

Cooling High/

Mediu

m/Low/

Silent 

operati

on

rpm

1,440/1,140/840/600

1,710/

1,300/890/

640

1,710/

1,440/

1,160/740

1,440/1,140/840/600

1,710/

1,300/890/

640

1,710/

1,440/

1,160/740

Heating High/

Mediu

m/Low/

Silent 

operati

on

rpm

1,620/

1,380/

1,100/760

1,720/

1,400/

1,100/760

1,910/

1,540/

1,180/800

1,940/

1,660/

1,330/920

1,620/

1,380/

1,100/760

1,720/

1,400/

1,100/760

1,910/

1,540/

1,180/800

1,940/

1,660/

1,330/920

Output

Rated

W

29

Sound power level

Cooling

dBA

54

59

60

54

59

60

Heating

dBA

56

59

60

56

59

60

Sound pressure level Cooling

High/Nom./Low/

Silent operation

dBA

38/32/25/19

45/34/26/

20

46/40/35/

32

38/32/25/19

45/34/26/

20

46/40/35/

32

Heating

High/Nom./Low/

Silent operation

dBA

40/34/28/

19

41/34/28/

19

45/37/29/

20

47/41/35/

32

40/34/28/

19

41/34/28/

19

45/37/29/

20

47/41/35/

32

Control systems

Infrared remote control

ARC466A9

Temperature control

Microcomputer control

Air direction control

Right, Left, Horizontal, Downward

Summary of Contents for FTXJ-MS

Page 1: ...Air Conditioning Technical Data Wall mounted unit EEDEN16 FTXJ MS FTXJ MW...

Page 2: ......

Page 3: ...FTXJ MW 1 Features 2 FTXJ MS FTXJ MW 2 2 Specifications 4 Technical Specifications 4 Electrical Specifications 5 3 Options 6 4 Dimensional drawings 7 5 Centre of gravity 8 6 Piping diagrams 9 7 Wiring...

Page 4: ...es pollen and mites for 99 or more Online controller optional control your indoor from any location with an app via your local network or internet and keep an overview on your energy consumption Whisp...

Page 5: ...61 388 438 446 361 388 438 446 Nom m min 8 4 8 6 9 6 10 5 8 4 8 6 9 6 10 5 cfm 298 303 340 372 298 303 340 372 Low m min 6 3 6 9 8 1 6 3 6 9 8 1 cfm 223 245 284 223 245 284 Silent operati on m min 3 8...

Page 6: ...apatite photocatalytic air purification filter Quantity 2 Standard Accessories Fixing screw for remote controller holder Quantity 2 Standard Accessories Indoor unit fixing screws Quantity 2 Standard...

Page 7: ...d remote control 3m Extension cord for wired remote control 5m Centralised control board up to 5 rooms Wiring adaptor normal open contact normal open pulse contact Interface adaptor for DIII NET Centr...

Page 8: ...UHFHLYHU LU GLVFKDUJH UDQJH DUWK WHUPLQDO 0 2Q WKH IURQW JULOOH 2Q WKH IURQW JULOOH 6HUYLFH FRYHU IL LQJ VFUHZ 2Q WKH IURQW JULOOH 2SHUDWLQJ VWDWH 7 0 7 06 1RWHV 7KH y y PDUN VKRZV WKH SLSLQJ GLUHFWLR...

Page 9: ...3 5 Split Sky Air FTXJ MS FTXJ MW 7 Indoor Unit FTXJ MS FTXJ MW 5 Centre of gravity 5 1 Centre of Gravity 7 0 7 06...

Page 10: ...lit Sky Air FTXJ MS FTXJ MW 8 6 Piping diagrams 6 1 Piping Diagrams 6 4CuT M 6 4CuT 9 5CuT 9 5CuT QGRRU XQLW URVVIORZ IDQ HDW H FKDQJHU HDW H FKDQJHU WKHUPLVWRU DQ PRWRU LHOG SLSLQJ LHOG SLSLQJ 5HIULJ...

Page 11: ...9 Indoor Unit FTXJ MS FTXJ MW 6 Piping diagrams 6 1 Piping Diagrams 6 4CuT M 6 4CuT 9 5CuT 12 7CuT QGRRU XQLW URVVIORZ IDQ HDW H FKDQJHU HDW H FKDQJHU WKHUPLVWRU DQ PRWRU LHOG SLSLQJ LHOG SLSLQJ 5HIUL...

Page 12: ...ORXUV 3LQN 5 65 51 51 75 6 3 6 6 6 6 5 25 8 6 3 6 6 6 3 5 7 Wr 6 3 3 6 7 5 0 8 05 8 9 7 25 51 8 5 6 0 0 6 5 7 0 6 0 6 0 6 06 06 06 Wr 6 6 6 6 5 25 31 8 5 25 31 8 5 25 31 8 0 0 2XWGRRU QGRRU UDPH JURXQ...

Page 13: ...NR70 NR75 NR80 NR85 NR90 10 20 30 40 50 60 70 80 90 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 63 125 250 500 1000 2000 4000 8000 dBA 3D092362A FTXJ25MW FTXJ25MS 1 2 3 4 5 38 25 41 28 Locatio...

Page 14: ...NR70 NR75 NR80 NR85 NR90 10 20 30 40 50 60 70 80 90 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 63 125 250 500 1000 2000 4000 8000 dBA 3D092359A FTXJ50MW FTXJ50MS 1 2 3 4 5 46 35 47 35 Locatio...

Page 15: ......

Page 16: ...in Europe N V has compiled the content of this leaflet to the best of its knowledge No express or implied warranty is given for the completeness accuracy re liability or fitness for particular purpose...

Reviews: