CAUTION

▪ ALWAYS use a user interface to adjust the angle of the

flap. When the flap is swinging and you move it forcibly
by hand, the mechanism will break.

▪ Be  careful  when  adjusting  the  louvers.  Inside  the  air

outlet, a fan is rotating at high speed.

The  movable  range  of  the  flap  varies  according  to  the  operation
mode. The flap will stop at the upper position when the airflow rate is
changed to low during the up and down swing setting.

a

b

c

a

Flap range in cooling or drying operation

b

Flap range in hating operation

c

Flap range in fan only operation

5.4.1

To adjust the airflow direction

1

To use auto swing, press 

.

Result: 

 will appear on the LCD.

Result: 

The flap (horizontal blade) will begin to swing.

2

To  use  fixed  position,  press 

  when  the  flap  reaches  the

desired position.

Result: 

 disappears from the LCD.

5.4.2

To adjust the louvers (vertical blades)

1

Hold 1 or both knobs and move the louvers.

a

a

a

Knobs

INFORMATION

When  the  unit  is  installed  in  a  corner  of  a  room,  the
direction  of  the  louvers  should  be  facing  away  from  the
wall. Efficiency will drop if a wall blocks the air.

5.5

Comfort airflow operation

This operation can be used in 

heating

 or 

cooling

 operation mode. It

will provide a comfortable wind that will NOT come in direct contact
with people. The system automatically sets the fixed airflow position
upward in Cooling and downward in Heating operation mode.

Cooling operation mode

Heating operation mode

INFORMATION

Powerful and Comfort airflow operation CANNOT be used
at the same time. The last selected function takes priority.
If  the  vertical  automatic  swing  is  selected,  Comfort  airflow
operation will be cancelled.

5.5.1

To start/stop Comfort airflow operation

1

Press 

 to start.

Result: 

The  flap  position  will  change, 

  is  displayed  on  the

LCD, and the airflow rate is set to automatic.

Mode

Position of flap…

Cooling/Drying

Up

Heating

Down

Note: 

Comfort airflow operation is NOT available in Fan only mode.

2

Press 

 to stop.

Result: 

The  flap  will  return  to  the  position  from  before  the  Comfort

airflow mode; 

 disappears from the LCD.

5.6

Powerful operation

This  operation  quickly  maximizes  the  cooling/heating  effect  in  any
operation mode. You can get the maximum capacity.

INFORMATION

Powerful operation CANNOT be used together with Econo
and  Comfort  airflow  operation.  The  last  selected  function
takes priority.

Powerful  operation  will  NOT  increase  the  capacity  of  the
unit if it already operates at maximum capacity.

5.6.1

To start/stop Powerful operation

1

Press 

 to start.

Result: 

  is  displayed  on  the  LCD.  Powerful  operation  runs

for 20 minutes; after that, operation returns to the previously set
mode.

2

Press 

 to stop.

Result: 

 disappears from the LCD.

Note:

 Powerful operation can be set only when the unit is running. If

you press 

 or if you change operation mode, operation will

be cancelled; 

 disappears from the LCD.

5.7

Econo operation

This  is  a  function  which  enables  efficient  operation  by  limiting  the
maximum power consumption value. This function is useful for cases
in which attention should be paid to ensure a circuit breaker will not
trip when the product runs alongside other appliances.

INFORMATION

▪ Powerful and Econo operation CANNOT be used at the

same time. The last selected function takes priority.

▪ Econo  operation  reduces  power  consumption  of  the

outdoor  unit  by  limiting  the  rotation  speed  of  the
compressor.  If  power  consumption  is  already  low,
Econo  operation  will  NOT  further  reduce  power
consumption.

Summary of Contents for FTXF50A2V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXF50D2V1B FTXF60D2V1B FTXF71D2V1B FTXF50A2V1B FTXF60A2V1B FTXF71A2V1B...

Page 2: ...this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure the best possible performance Request the installer to inform...

Page 3: ...igerant inside the unit is mildly flammable but normally does NOT leak If the refrigerant leaks in the room and comes in contact with fire from a burner a heater or a cooker this may result in fire or...

Page 4: ...an electrical shock or fire Contact your dealer In case of accidental refrigerant leaks make sure there are no naked flames The refrigerant itself is entirely safe non toxic and mildly flammable but...

Page 5: ...Insert both batteries at once 3 Put the cover back 2 3 1 AAA LR03 4 2 To mount the user interface holder 2 b c a a User interface b Screws field supply c User interface holder 1 Choose a place where...

Page 6: ...c Operation mode Drying Operation mode Heating Operation mode Cooling Operation mode Fan only Shows the set temperature 1 Press one or more times to select the operation mode Result The mode will be s...

Page 7: ...tical automatic swing is selected Comfort airflow operation will be cancelled 5 5 1 To start stop Comfort airflow operation 1 Press to start Result The flap position will change is displayed on the LC...

Page 8: ...to 12 hours 2 Press to stop Result disappears from the LCD and the timer lamp goes off 5 8 3 To combine OFF timer and ON timer 1 To set the timers refer to 5 8 1 To start stop OFF timer operation 4 8...

Page 9: ...ects containing water on the unit CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury CAUTION Do NOT touch the heat exchanger fins Th...

Page 10: ...ealer WARNING Stop operation and shut OFF the power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electrical shock or fire Contact...

Page 11: ......

Page 12: ...3P511999 6J 2021 07 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...

Reviews: