6 Energy saving and optimum operation

Operation manual

8

FTXF50~7 FTXF50~71A2V1B

Daikin room air conditioner

3P511999-6J – 2021.07

5.7.1

To start/stop Econo operation

1

Press 

 to start.

Result: 

 is displayed on the LCD.

2

Press 

 to stop.

Result: 

 disappears from the LCD.

5.8

OFF/ON timer operation

Timer  functions  are  useful  for  automatically  switching  the  air
conditioner off/on at night or in the morning. You can also use OFF
timer and ON timer in combination.

INFORMATION

Program the timer again in case of:

▪ A breaker has turned the unit off.

▪ A power failure.

▪ After replacing batteries in the user interface.

5.8.1

To start/stop OFF timer operation

Use  this  feature  if  the  unit  is  operating  and  you  want  to  stop
operation after a certain time.

1

Press 

 to start.

Result: 

 is displayed on the LCD and the timer lamp lights

up.

INFORMATION

Each time 

 is pressed, the time setting advances by

1 hour. The timer can be set between 1 to 9 hours.

2

Press 

 to stop.

Result: 

  disappears  from  the  LCD  and  the  timer  lamp

goes off.

INFORMATION

When you set the ON/OFF timer, the time setting is stored
in  the  memory.  The  memory  will  be  reset  when  the  user
interface batteries are replaced.

Use of night set mode in combination with OFF timer

The  air  conditioner  automatically  adjusts  the  temperature
setting  (0.5°C  up  in  cooling,  2.0°C  down  in  heating)  to
prevent 

excessive 

cooling/heating 

and 

ensure 

a

comfortable sleeping temperature.

5.8.2

To start/stop ON timer operation

1

Press 

 to start.

Result: 

 is displayed on the LCD and the timer lamp lights

up.

INFORMATION

Each time 

 is pressed, the time setting advances by

1 hour. The timer can be set between 1 to 12 hours.

2

Press 

 to stop.

Result: 

  disappears  from  the  LCD  and  the  timer  lamp

goes off.

5.8.3

To combine OFF timer and ON timer

1

To  set  the  timers,  refer  to 

"5.8.1  To  start/stop  OFF  timer

operation"

  [

4

  8]  and 

"5.8.2  To  start/stop  ON  timer

operation"

 [

4

 8].

Result: 

 and 

 are displayed on the LCD.

2

Example of what is displayed on the LCD if you combine the 2

timers: 

6

Energy saving and optimum
operation

INFORMATION

▪ Even if the unit is turned OFF, it consumes electricity.

▪ When the power turns back on after a power break, the

previously selected mode will be resumed.

CAUTION

NEVER  expose  little  children,  plants  or  animals  directly  to
the airflow.

NOTICE

Do NOT place objects below the indoor and/or outdoor unit
that  may  get  wet.  Otherwise  condensation  on  the  unit  or
refrigerant pipes, air filter dirt or drain blockage may cause
dripping,  and  objects  under  the  unit  may  get  dirty  or
damaged.

WARNING

Do  NOT  place  a  flammable  spray  bottle  near  the  air
conditioner and do NOT use sprays near the unit. Doing so
may result in a fire.

CAUTION

Do  NOT  operate  the  system  when  using  a  room
fumigation-type  insecticide.  Chemicals  could  collect  in  the
unit,  and  endanger  the  health  of  people  who  are
hypersensitive to chemicals.

7

Maintenance and service

7.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance.

About the refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R32

Global warming potential (GWP) value: 675

NOTICE

Applicable  legislation  on 

fluorinated  greenhouse  gases

requires  that  the  refrigerant  charge  of  the  unit  is  indicated
both in weight and CO

2

 equivalent.

Formula  to  calculate  the  quantity  in  CO

2

  equivalent

tonnes:

  GWP  value  of  the  refrigerant  ×  total  refrigerant

charge [in kg] / 1000

Please contact your installer for more information.

Summary of Contents for FTXF50A2V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXF50D2V1B FTXF60D2V1B FTXF71D2V1B FTXF50A2V1B FTXF60A2V1B FTXF71A2V1B...

Page 2: ...this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure the best possible performance Request the installer to inform...

Page 3: ...igerant inside the unit is mildly flammable but normally does NOT leak If the refrigerant leaks in the room and comes in contact with fire from a burner a heater or a cooker this may result in fire or...

Page 4: ...an electrical shock or fire Contact your dealer In case of accidental refrigerant leaks make sure there are no naked flames The refrigerant itself is entirely safe non toxic and mildly flammable but...

Page 5: ...Insert both batteries at once 3 Put the cover back 2 3 1 AAA LR03 4 2 To mount the user interface holder 2 b c a a User interface b Screws field supply c User interface holder 1 Choose a place where...

Page 6: ...c Operation mode Drying Operation mode Heating Operation mode Cooling Operation mode Fan only Shows the set temperature 1 Press one or more times to select the operation mode Result The mode will be s...

Page 7: ...tical automatic swing is selected Comfort airflow operation will be cancelled 5 5 1 To start stop Comfort airflow operation 1 Press to start Result The flap position will change is displayed on the LC...

Page 8: ...to 12 hours 2 Press to stop Result disappears from the LCD and the timer lamp goes off 5 8 3 To combine OFF timer and ON timer 1 To set the timers refer to 5 8 1 To start stop OFF timer operation 4 8...

Page 9: ...ects containing water on the unit CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury CAUTION Do NOT touch the heat exchanger fins Th...

Page 10: ...ealer WARNING Stop operation and shut OFF the power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electrical shock or fire Contact...

Page 11: ......

Page 12: ...3P511999 6J 2021 07 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...

Reviews: