background image

4 Before operation

Operation manual 

6

FTXF20~42C5V1B 

Daikin room air conditioner

3P520336-9K – 2020.08

Icon

Description

Airflow rate = High

Airflow rate = Medium high

Airflow rate = Medium

Airflow rate = Medium low

Airflow rate = Low

Comfort operation is active

Auto vertical swing is active

ON timer is active

OFF timer is active

3.2.3

To operate the user interface

a

a

Signal receiver

1

Aim  the  signal  transmitter  at  the  signal  receiver  on  the  indoor
unit (maximum distance for communication is 7 m).

Result: 

When  the  indoor  unit  receives  a  signal  from  the  user

interface, you will hear a sound:

Sound

Description

Beep-beep

Operation starts.

Beep

Setting changes.

Long beep

Operation stops.

4

Before operation

4.1

To mount the user interface holder

b

c

a

a

User interface

b

Screws (field supply)

c

User interface holder

1

Choose a place where the signals reach the unit.

2

Attach the holder with screws to the wall or a similar location.

3

Hang the user interface on the user interface holder.

4.2

To insert the batteries

The batteries will last for about 1 year.

1

Remove the back cover.

2

Insert both batteries at once.

3

Put the cover back.

2

3

1

AAA.LR03

4.3

To turn on the power supply

1

Turn the circuit breaker on.

Result: 

The  flap  of  the  indoor  unit  will  open  and  close  to  set  the

reference position.

5

Operation

5.1

Operation range

Use the system in the following temperature and humidity ranges for
safe and effective operation.

Operation mode

Operation range

Cooling

(a)(b)

▪ Outdoor temperature: –10~46°C DB

▪ Indoor temperature: 18~32°C DB

▪ Indoor humidity: ≤80%

Heating

(a)

▪ Outdoor temperature: –15~24°C DB

▪ Indoor temperature: 10~30°C DB

Drying

(a)

▪ Outdoor temperature: –10~46°C DB

▪ Indoor temperature: 18~32°C DB

▪ Indoor humidity: ≤80%

(a)

A safety device might stop the operation of the system if the unit
runs outside its operation range.

(b)

Condensation and water dripping might occur if the unit runs
outside its operation range.

5.2

When to use which feature

You can use the following table to determine which features to use:

Feature

Tasks

Basic features

 Operation modes and

temperature

To start/stop the system and to set the
temperature:

▪ Heat up or cool down a room.

▪ Blow air in a room without heating or

cooling.

▪ Decrease the humidity in a room.

▪ In  Automatic  mode,  automatically

select  an  appropriate  temperature
and operation mode.

 Airflow direction

To adjust the airflow direction (swing or
fixed position).

Summary of Contents for FTXF20C5V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXF20C5V1B FTXF25C5V1B FTXF35C5V1B FTXF42C5V1B...

Page 2: ...s while the air conditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 1 About the documentation 1 1 About this document Thank you for purchasing this product Pl...

Page 3: ...ontains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries must be treated at a specialized treatment facility for reuse By ensuring waste batterie...

Page 4: ...ies off Otherwise an electric shock and injury may result CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury WARNING Be careful with...

Page 5: ...abled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other appliances or contact your install...

Page 6: ...atteries at once 3 Put the cover back 2 3 1 AAA LR03 4 3 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and close to set the reference position...

Page 7: ...system s cooling or heating effect decreases when the outside temperature is too high or too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heat...

Page 8: ...e air 5 3 4 Comfort airflow operation This operation can be used in heating or cooling operation mode It will provide a comfortable wind that will NOT come in direct contact with people The system aut...

Page 9: ...the time setting is stored in the memory The memory will be reset when the user interface batteries are replaced Use of night set mode in combination with OFF timer The air conditioner automatically...

Page 10: ...ct the dealer where you purchased the unit Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired WARNING Do NOT pierce or burn refrigera...

Page 11: ...l detergent diluted in lukewarm water Dry the air filters in the shade It is recommended to clean the air filters every 2 weeks For FTXF20 25C5V1B and ATXF20 25C5V1B INFORMATION During cooling operati...

Page 12: ...8 1 3 Symptom A ticking sound is heard This sound is generated when the unit slightly expands or contracts with changes in temperature 8 1 4 Symptom A whistling sound is heard This sound is generated...

Page 13: ...ing mode Compressor system sensor abnormality Position sensor abnormality DC voltage current sensor abnormality Outdoor temperature thermistor abnormality Discharge pipe thermistor abnormality Outdoor...

Page 14: ......

Page 15: ......

Page 16: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P520336 9K 2020 08 Copyright 20...