8 Troubleshooting

Operation manual 

12

FTXF20~42C5V1B 

Daikin room air conditioner

3P520336-9K – 2020.08

8

Troubleshooting

If one of the following malfunctions occur, take the measures shown
below and contact your dealer.

WARNING

Stop  operation  and  shut  off  the  power  if  anything
unusual occurs (burning smells etc.).

Leaving  the  unit  running  under  such  circumstances  may
cause breakage, electric shock or fire. Contact your dealer.

The system MUST be repaired by a qualified service person.

Malfunction

Measure

If a safety device such as a fuse, a
breaker or an earth leakage breaker
frequently actuates or the ON/OFF
switch does NOT properly work.

Turn OFF the main power
switch.

If water leaks from the unit.

Stop the operation.

The operation switch does NOT work
well.

Turn OFF the power
supply.

If the user interface display indicates the
unit number, the operation lamp flashes
and the malfunction code appears.

Notify your installer and
report the malfunction
code.

If  the  system  does  NOT  operate  properly  except  for  the  above
mentioned cases and none of the above mentioned malfunctions is
evident,  investigate  the  system  in  accordance  with  the  following
procedures.

INFORMATION

Refer  to  the  reference  guide  located  on 

http://

www.daikineurope.com/support-and-manuals/product-
information/

 for more troubleshooting tips.

If  after  checking  all  above  items,  it  is  impossible  to  fix  the  problem
yourself, contact your installer and state the symptoms, the complete
model name of the unit (with manufacturing number if possible) and
the installation date (possibly listed on the warranty card).

8.1

Symptoms that are NOT system
malfunctions

The following symptoms are NOT system malfunctions:

8.1.1

Symptom: A sound like water flowing is
heard

▪ This sound is caused by the refrigerant flowing in the unit.

▪ This  sound  may  be  generated  when  water  is  flowing  away  from

the unit during cooling or drying operation.

8.1.2

Symptom: A blowing sound is heard

This sound is generated when the direction of the refrigerant flow is
changed (e.g. when switching from cooling to heating).

8.1.3

Symptom: A ticking sound is heard

This sound is generated when the unit slightly expands or contracts
with changes in temperature.

8.1.4

Symptom: A whistling sound is heard

This  sound  is  generated  by  the  refrigerant  flowing  during  defrost
operation.

8.1.5

Symptom: A clicking sound during
operation or idle time is heard

This  sound  is  generated  when  the  refrigerant  control  valves  or
electrical parts operate.

8.1.6

Symptom: A clapping sound is heard

This sound is generated when an external device sucks air out of the
room (e.g. exhaust fan, extractor hood) while the doors and windows
in  the  room  are  closed.  Open  the  doors  or  windows,  or  turn  off  the
device.

8.1.7

Symptom: The outdoor fan rotates while
the air conditioner is not in operation

After  operation  has  stopped.

  The  outdoor  fan  continues  to

rotate for another 30 seconds for system protection.

While the air conditioner is not in operation.

 When the outdoor

temperature  is  very  high,  the  outdoor  fan  starts  to  rotate  for
system protection.

8.2

Solving problems based on error
codes

Fault diagnosis by user interface

If the unit runs into a problem, you can identify the fault by checking
the error code by the user interface. It is important to understand the
problem  and  take  measures  before  resetting  the  error  code.  This
should be done by a licensed installer or your local dealer.

INFORMATION

See the service manual for:

▪ The complete list of error codes

▪ A  more  detailed  troubleshooting  guideline  for  each

error

To check the error code by the user interface

1

Aim  the  user  interface  at  the  unit  and  press 

  for  about

5 seconds.

Result: 

 blinks in the temperature setting display section.

2

Aim  the  user  interface  at  the  unit  and  press 

  repeatedly

until a continuous beep is heard.

Result: 

The code is now displayed on the display.

INFORMATION

▪ A  short  beep  and  2  consecutive  beeps  indicate  non-

corresponding codes.

▪ To  cancel  the  code  display,  hold 

  for  5  seconds.

The  code  will  also  disappear  from  the  display  if  the
button is NOT pressed within 1 minute.

System

Error code

Description

Normal

Refrigerant shortage

Overvoltage detection

Signal transmission error (between indoor and
outdoor unit)

Indoor/outdoor unit combination fault

Indoor unit

Error code

Description

Indoor unit PCB abnormality

Summary of Contents for FTXF20C5V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXF20C5V1B FTXF25C5V1B FTXF35C5V1B FTXF42C5V1B...

Page 2: ...s while the air conditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 1 About the documentation 1 1 About this document Thank you for purchasing this product Pl...

Page 3: ...ontains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries must be treated at a specialized treatment facility for reuse By ensuring waste batterie...

Page 4: ...ies off Otherwise an electric shock and injury may result CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury WARNING Be careful with...

Page 5: ...abled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other appliances or contact your install...

Page 6: ...atteries at once 3 Put the cover back 2 3 1 AAA LR03 4 3 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and close to set the reference position...

Page 7: ...system s cooling or heating effect decreases when the outside temperature is too high or too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heat...

Page 8: ...e air 5 3 4 Comfort airflow operation This operation can be used in heating or cooling operation mode It will provide a comfortable wind that will NOT come in direct contact with people The system aut...

Page 9: ...the time setting is stored in the memory The memory will be reset when the user interface batteries are replaced Use of night set mode in combination with OFF timer The air conditioner automatically...

Page 10: ...ct the dealer where you purchased the unit Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired WARNING Do NOT pierce or burn refrigera...

Page 11: ...l detergent diluted in lukewarm water Dry the air filters in the shade It is recommended to clean the air filters every 2 weeks For FTXF20 25C5V1B and ATXF20 25C5V1B INFORMATION During cooling operati...

Page 12: ...8 1 3 Symptom A ticking sound is heard This sound is generated when the unit slightly expands or contracts with changes in temperature 8 1 4 Symptom A whistling sound is heard This sound is generated...

Page 13: ...ing mode Compressor system sensor abnormality Position sensor abnormality DC voltage current sensor abnormality Outdoor temperature thermistor abnormality Discharge pipe thermistor abnormality Outdoor...

Page 14: ......

Page 15: ......

Page 16: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P520336 9K 2020 08 Copyright 20...

Reviews: