background image

3 About the system

Operation manual 

5

FTXF20~42C5V1B 
Daikin room air conditioner
3P520336-9K – 2020.08

a

c d

ON/OFF

f

g

l

h

i

k

j

e

b

a

Air inlet

b

Air outlet

c

Flap (horizontal blade)

d

Louvers (vertical blades)

e

Front panel

f

Model name plate

g

Room temperature sensor

h

Signal receiver

i

Operation indicator (green)

j

Timer lamp (orange)

k

Indoor unit ON/OFF switch

l

Air filter

ON/OFF button

If the user interface is missing, you can use the ON/OFF button on
the  indoor  unit  to  start/stop  operation.  When  operation  is  started
using this button, the following settings are used:

▪ Operation mode = Automatic

▪ Temperature setting = 25°C

▪ Airflow rate = Automatic

3.2

About the user interface

Direct  sunlight.

  Do  NOT  expose  the  user  interface  to  direct

sunlight.

Dust.

  Dust  on  the  signal  transmitter  or  receiver  will  reduce

sensitivity. Wipe off dust with a soft cloth.

Fluorescent  lights.

  Signal  communication  might  be  disabled  if

fluorescent  lamps  are  in  the  room.  In  that  case,  contact  your
installer.

Other  appliances.

  If  the  user  interface  signals  operate  other

appliances, move the other appliances, or contact your installer.

Curtains.

 Make sure that the signal between the unit and the user

interface is NOT blocked by curtains or other objects.

NOTICE

▪ Do NOT drop the user interface.

▪ Do NOT let the user interface get wet.

3.2.1

Components: User interface

b

d

c

f

h

e

m

l

k

i

j

a

g

a

Signal transmitter

b

LCD display

c

ON/OFF button

d

Fan setting button

e

Temperature adjustment button

f

Swing button

g

Timer cancel button

h

ON timer button

i

OFF timer button

j

Comfort airflow button

k

Econo button

l

Mode selector button

m

Powerful button

3.2.2

Status: User interface LCD

Icon

Description

Operation mode = Automatic

Operation mode = Drying

Operation mode = Heating

Operation mode = Cooling

Operation mode = Fan only

Powerful operation is active

Econo operation is active

Operation is active

The indoor unit receives a signal
from the user interface

Current temperature setting

Airflow rate = Automatic

Airflow rate = Indoor unit quiet

Summary of Contents for FTXF20C5V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXF20C5V1B FTXF25C5V1B FTXF35C5V1B FTXF42C5V1B...

Page 2: ...s while the air conditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 1 About the documentation 1 1 About this document Thank you for purchasing this product Pl...

Page 3: ...ontains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries must be treated at a specialized treatment facility for reuse By ensuring waste batterie...

Page 4: ...ies off Otherwise an electric shock and injury may result CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury WARNING Be careful with...

Page 5: ...abled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other appliances or contact your install...

Page 6: ...atteries at once 3 Put the cover back 2 3 1 AAA LR03 4 3 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and close to set the reference position...

Page 7: ...system s cooling or heating effect decreases when the outside temperature is too high or too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heat...

Page 8: ...e air 5 3 4 Comfort airflow operation This operation can be used in heating or cooling operation mode It will provide a comfortable wind that will NOT come in direct contact with people The system aut...

Page 9: ...the time setting is stored in the memory The memory will be reset when the user interface batteries are replaced Use of night set mode in combination with OFF timer The air conditioner automatically...

Page 10: ...ct the dealer where you purchased the unit Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired WARNING Do NOT pierce or burn refrigera...

Page 11: ...l detergent diluted in lukewarm water Dry the air filters in the shade It is recommended to clean the air filters every 2 weeks For FTXF20 25C5V1B and ATXF20 25C5V1B INFORMATION During cooling operati...

Page 12: ...8 1 3 Symptom A ticking sound is heard This sound is generated when the unit slightly expands or contracts with changes in temperature 8 1 4 Symptom A whistling sound is heard This sound is generated...

Page 13: ...ing mode Compressor system sensor abnormality Position sensor abnormality DC voltage current sensor abnormality Outdoor temperature thermistor abnormality Discharge pipe thermistor abnormality Outdoor...

Page 14: ......

Page 15: ......

Page 16: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P520336 9K 2020 08 Copyright 20...

Reviews: