background image

Table of contents

Operation manual 

2

FTXF20~42C5V1B 

Daikin room air conditioner

3P520336-9K – 2020.08

Table of contents

1 About the documentation

2

1.1

About this document..................................................................

2

2 User safety instructions

2

2.1

General......................................................................................

2

2.2

Instructions for safe operation ...................................................

3

3 About the system

4

3.1

Indoor unit .................................................................................

4

3.2

About the user interface ............................................................

5

3.2.1

Components: User interface .......................................

5

3.2.2

Status: User interface LCD .........................................

5

3.2.3

To operate the user interface......................................

6

4 Before operation

6

4.1

To mount the user interface holder ...........................................

6

4.2

To insert the batteries................................................................

6

4.3

To turn on the power supply......................................................

6

5 Operation

6

5.1

Operation range ........................................................................

6

5.2

When to use which feature........................................................

6

5.3

Operation mode and temperature setpoint................................

7

5.3.1

To start/stop operation mode and to set the
temperature.................................................................

7

5.3.2

Airflow rate ..................................................................

7

5.3.3

Airflow direction...........................................................

8

5.3.4

Comfort airflow operation............................................

8

5.3.5

Powerful operation ......................................................

8

5.3.6

Econo operation..........................................................

9

5.3.7

OFF/ON timer operation .............................................

9

6 Energy saving and optimum operation

9

7 Maintenance and service

10

7.1

Overview: Maintenance and service .........................................

10

7.2

To clean the indoor unit and user interface ...............................

10

7.3

To clean the front panel.............................................................

11

7.4

About the air filters ....................................................................

11

7.5

To clean the air filters ................................................................

11

7.6

To take following items into account before a long idle period..

11

8 Troubleshooting

12

8.1

Symptoms that are NOT system malfunctions ..........................

12

8.1.1

Symptom: A sound like water flowing is heard ........... 12

8.1.2

Symptom: A blowing sound is heard........................... 12

8.1.3

Symptom: A ticking sound is heard............................. 12

8.1.4

Symptom: A whistling sound is heard ......................... 12

8.1.5

Symptom: A clicking sound during operation or idle
time is heard ............................................................... 12

8.1.6

Symptom: A clapping sound is heard ......................... 12

8.1.7

Symptom: The outdoor fan rotates while the air
conditioner is not in operation ..................................... 12

8.2

Solving problems based on error codes....................................

12

9 Disposal

13

1

About the documentation

1.1

About this document

Thank you for purchasing this product. Please:

▪ Read  the  documentation  carefully  before  operating  the  user

interface to ensure the best possible performance.

▪ Request the installer to inform you about the settings that he used

to  configure  your  system.  Check  if  he  has  filled  in  the  installer
settings tables. If not, request him to do so.

▪ Keep the documentation for future reference.

Target audience

End users

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety  instructions  that  you  must  read  before  operating  your

system

▪ Format: Paper (in the box of the indoor unit)

Operation manual:

▪ Quick guide for basic usage

▪ Format: Paper (in the box of the indoor unit)

User reference guide:

▪ Detailed  step-by-step  instructions  and  background  information

for basic and advanced usage

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.

The original documentation is written in English. All other languages
are translations.

2

User safety instructions

Always observe the following safety instructions and regulations.

2.1

General

WARNING

If you are NOT sure how to operate the
unit, contact your installer.

WARNING

Children aged from 8 years and above
and persons with reduced physical,
sensory or mental capabilities or lack
of experience and knowledge can only
use this appliance if they have been

Summary of Contents for FTXF20C5V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXF20C5V1B FTXF25C5V1B FTXF35C5V1B FTXF42C5V1B...

Page 2: ...s while the air conditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 1 About the documentation 1 1 About this document Thank you for purchasing this product Pl...

Page 3: ...ontains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries must be treated at a specialized treatment facility for reuse By ensuring waste batterie...

Page 4: ...ies off Otherwise an electric shock and injury may result CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury WARNING Be careful with...

Page 5: ...abled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other appliances or contact your install...

Page 6: ...atteries at once 3 Put the cover back 2 3 1 AAA LR03 4 3 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and close to set the reference position...

Page 7: ...system s cooling or heating effect decreases when the outside temperature is too high or too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heat...

Page 8: ...e air 5 3 4 Comfort airflow operation This operation can be used in heating or cooling operation mode It will provide a comfortable wind that will NOT come in direct contact with people The system aut...

Page 9: ...the time setting is stored in the memory The memory will be reset when the user interface batteries are replaced Use of night set mode in combination with OFF timer The air conditioner automatically...

Page 10: ...ct the dealer where you purchased the unit Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired WARNING Do NOT pierce or burn refrigera...

Page 11: ...l detergent diluted in lukewarm water Dry the air filters in the shade It is recommended to clean the air filters every 2 weeks For FTXF20 25C5V1B and ATXF20 25C5V1B INFORMATION During cooling operati...

Page 12: ...8 1 3 Symptom A ticking sound is heard This sound is generated when the unit slightly expands or contracts with changes in temperature 8 1 4 Symptom A whistling sound is heard This sound is generated...

Page 13: ...ing mode Compressor system sensor abnormality Position sensor abnormality DC voltage current sensor abnormality Outdoor temperature thermistor abnormality Discharge pipe thermistor abnormality Outdoor...

Page 14: ......

Page 15: ......

Page 16: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P520336 9K 2020 08 Copyright 20...

Reviews: