background image

7 Troubleshooting

Operation manual

9

FTXF20~3 FTXF20~25B5V1B
Daikin room air conditioner
3P520336-3E – 2019.09

6.2

To clean the indoor unit and user
interface

NOTICE

▪ Do  NOT  use  gasoline,  benzene,  thinner  polishing

powder  or  liquid  insecticide. 

Possible  consequence:

Discoloration and deformation.

▪ Do  NOT  use  water  or  air  of  40°C  or  higher. 

Possible

consequence: 

Discoloration and deformation.

▪ Do NOT use polishing compounds.

▪ Do 

NOT 

use 

scrubbing 

brush. 

Possible

consequence: 

The surface finishing peels off.

DANGER: RISK OF ELECTROCUTION

Before  cleaning,  be  sure  to  stop  the  operation,  turn  the
breaker  off  or  pull  out  the  supply  cord.  Otherwise,  an
electric shock and injury may result.

1

Clean  with  a  soft  cloth.  If  it  is  difficult  to  remove  stains,  use
water or a neutral detergent.

6.3

To clean the front panel

1

Clean the front panel with a soft cloth. If it is difficult to remove
stains, use water or a neutral detergent.

6.4

About the air filters

Operating the unit with dirty filters means that the filter:

▪ CANNOT deodorize the air,

▪ CANNOT clean the air,

▪ poor heating/cooling,

▪ causes odour.

6.5

To clean the air filters

1

Push the tab at the centre of each air filter, then pull it down.

2

Pull out the air filters.

2

1

3

Wash  the  air  filters  with  water  or  clean  them  with  a  vacuum
cleaner.

4

Soak in lukewarm water for about 10 to 15 minutes.

INFORMATION

▪ If the dust does NOT come off easily, wash them with a

neutral detergent diluted in lukewarm water. Dry the air
filters in the shade.

▪ It  is  recommended  to  clean  the  air  filters  every  2

weeks.

6.6

To take following items into
account before a long idle period

Operate the unit in 

fan only

 mode for several hours to dry the inside

of the unit.

1

Press 

 and select fan only operation.

2

Press 

 to start operation.

3

After operation stops, turn the breaker off.

4

Clean the air filters and replace them in their original position.

5

Remove the batteries from the user interface.

INFORMATION

It  is  recommended  to  have  periodical  maintenance
performed  by  a  specialist.  For  specialist  maintenance,
contact  your  dealer.  Maintenance  costs  shall  be  borne  by
the customer.

In  certain  operating  conditions  the  inside  of  the  unit  may
get dirty after several seasons of use. This results in poor
performance.

7

Troubleshooting

If one of the following malfunctions occur, take the measures shown
below and contact your dealer.

WARNING

Stop  operation  and  shut  off  the  power  if  anything
unusual occurs (burning smells etc.).

Leaving  the  unit  running  under  such  circumstances  may
cause breakage, electric shock or fire. Contact your dealer.

The system MUST be repaired by a qualified service person.

Summary of Contents for FTXF20A5V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXF20A5V1B FTXF25A5V1B FTXF35A5V1B FTXF20B5V1B FTXF25B5V1B...

Page 2: ...ment Thank you for purchasing this product Please Keep the documentation for future reference Target audience End users INFORMATION This appliance is intended to be used by expert or trained users in...

Page 3: ...e disabled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other appliances or contact your in...

Page 4: ...Remove the back cover 2 Insert both batteries at once 3 Put the cover back 2 3 1 AAA LR03 3 3 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open an...

Page 5: ...or heating effect decreases when the outside temperature is too high or too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In th...

Page 6: ...drop if a wall blocks the air 4 3 4 Comfort airflow operation This operation can be used in heating or cooling operation mode It will provide a comfortable wind that will NOT come in direct contact wi...

Page 7: ...amp lights up INFORMATION Each time is pressed the time setting advances by 1 hour The timer can be set between 1 to 12 hours 2 Press to stop Result disappears from the LCD and the timer lamp goes off...

Page 8: ...ergy 6 Maintenance and service 6 1 Overview Maintenance and service The installer has to perform a yearly maintenance About the refrigerant This product contains fluorinated greenhouse gases Do NOT ve...

Page 9: ...ers 2 1 3 Wash the air filters with water or clean them with a vacuum cleaner 4 Soak in lukewarm water for about 10 to 15 minutes INFORMATION If the dust does NOT come off easily wash them with a neut...

Page 10: ...s See 6 Maintenance and service 48 Check for open doors or windows Close doors and windows to prevent wind from coming in Check if the unit operates in Econo operation Refer to 4 3 6 Econo operation 4...

Page 11: ...e fault It is important to understand the problem and take measures before resetting the error code This should be done by a licensed installer or your local dealer To see the error code on the user i...

Page 12: ...TEMLER SAN T C A STANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P520336 3E 2...

Reviews: