6 Maintenance and service

Operation manual

8

FTXF20~3 FTXF20~25B5V1B

Daikin room air conditioner

3P520336-3E – 2019.09

WARNING

Do  NOT  place  a  flammable  spray  bottle  near  the  air
conditioner and do NOT use sprays near the unit. Doing so
may result in a fire.

Observe  the  following  precautions  to  ensure  the  system  operates
properly.

▪ Prevent  direct  sunlight  from  entering  a  room  during  cooling

operation by using curtains or blinds.

▪ Make  sure  the  area  is  well  ventilated.  Do  NOT  block  any

ventilation openings.

▪ Ventilate  often.  Extended  use  requires  special  attention  to

ventilation.

▪ Keep doors and windows closed. If the doors and windows remain

open,  air  will  flow  out  of  your  room  causing  a  decrease  in  the
cooling or heating effect.

▪ Be  careful  NOT  to  cool  or  heat  too  much.  To  save  energy,  keep

the temperature setting at a moderate level.

▪ NEVER place objects near the air inlet or the air outlet of the unit.

Doing  so  may  cause  a  reduced  heating/cooling  effect  or  stop
operation.

▪ Turn off the main power supply switch to the unit when the unit is

NOT  used  for  longer  periods  of  time.  If  the  main  power  supply
switch  is  on,  the  unit  consumes  electricity.  Before  restarting  the
unit,  turn  on  the  main  power  supply  switch  6  hours  before
operation to ensure smooth running.

▪ Turn the breaker off when the unit is NOT used for longer periods

of time. If the breaker is on, the unit consumes electricity. Before
restarting the unit, turn the breaker on 6 hours before operation to
ensure smooth running.

▪ Condensation  may  form  if  the  humidity  is  above  80%  or  if  the

drain outlet gets blocked.

▪ Adjust  the  room  temperature  properly  for  a  comfortable

environment.  Avoid  excessive  heating  or  cooling.  Notice  that  it
may  take  some  time  for  the  room  temperature  to  reach  the  set
temperature. Consider using the timer setting options.

▪ Adjust the air flow direction to avoid cool air from gathering on the

floor  or  warm  air  against  the  ceiling.  (Up  during  cooling  or  dry
operation to the ceiling and down during heating operation.)

▪ Avoid direct air flow to room inhabitants.

▪ Operate  the  system  within  the  recommended  temperature  range

(26~28°C for cooling and 20~24°C for heating) to save energy.

6

Maintenance and service

6.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance.

About the refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R32

Global warming potential (GWP) value: 675

NOTICE

Applicable  legislation  on 

fluorinated  greenhouse  gases

requires  that  the  refrigerant  charge  of  the  unit  is  indicated
both in weight and CO

2

 equivalent.

Formula  to  calculate  the  quantity  in  CO2  equivalent
tonnes:

  GWP  value  of  the  refrigerant  ×  total  refrigerant

charge [in kg] / 1000

Please contact your installer for more information.

WARNING

The  refrigerant  inside  the  unit  is  mildly  flammable,  but
normally  does  NOT  leak.  If  the  refrigerant  leaks  in  the
room  and  comes  in  contact  with  fire  from  a  burner,  a
heater, or a cooker, this may result in fire, or the formation
of a harmful gas.

Turn  off  any  combustible  heating  devices,  ventilate  the
room,  and  contact  the  dealer  where  you  purchased  the
unit.

Do  NOT  use  the  unit  until  a  service  person  confirms  that
the  part  from  which  the  refrigerant  leaked  has  been
repaired.

WARNING

▪ Do NOT pierce or burn refrigerant cycle parts.

▪ Do NOT use cleaning materials or means to accelerate

the  defrosting  process  other  than  those  recommended
by the manufacturer.

▪ Be  aware  that  the  refrigerant  inside  the  system  is

odourless.

WARNING

The  appliance  shall  be  stored  in  a  room  without
continuously  operating  ignition  sources  (example:  open
flames, an operating gas appliance or an operating electric
heater).

NOTICE

Maintenance  MUST  be  done  by  an  authorized  installer  or
service agent.

We  recommend  performing  maintenance  at  least  once  a
year. However, applicable legislation might require shorter
maintenance intervals.

DANGER: RISK OF ELECTROCUTION

To  clean  the  air  conditioner  or  air  filter,  be  sure  to  stop
operation  and  turn  all  power  supplies  off.  Otherwise,  an
electric shock and injury may result.

WARNING

To prevent electric shocks or fire:

▪ Do NOT rinse the unit.

▪ Do NOT operate the unit with wet hands.

▪ Do NOT place any objects containing water on the unit.

CAUTION

After  a  long  use,  check  the  unit  stand  and  fitting  for
damage. If damaged, the unit may fall and result in injury.

CAUTION

Do  NOT  touch  the  heat  exchanger  fins.  These  fins  are
sharp and could result in cutting injuries.

WARNING

Be careful with ladders when working in high places.

Summary of Contents for FTXF20A5V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXF20A5V1B FTXF25A5V1B FTXF35A5V1B FTXF20B5V1B FTXF25B5V1B...

Page 2: ...ment Thank you for purchasing this product Please Keep the documentation for future reference Target audience End users INFORMATION This appliance is intended to be used by expert or trained users in...

Page 3: ...e disabled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other appliances or contact your in...

Page 4: ...Remove the back cover 2 Insert both batteries at once 3 Put the cover back 2 3 1 AAA LR03 3 3 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open an...

Page 5: ...or heating effect decreases when the outside temperature is too high or too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In th...

Page 6: ...drop if a wall blocks the air 4 3 4 Comfort airflow operation This operation can be used in heating or cooling operation mode It will provide a comfortable wind that will NOT come in direct contact wi...

Page 7: ...amp lights up INFORMATION Each time is pressed the time setting advances by 1 hour The timer can be set between 1 to 12 hours 2 Press to stop Result disappears from the LCD and the timer lamp goes off...

Page 8: ...ergy 6 Maintenance and service 6 1 Overview Maintenance and service The installer has to perform a yearly maintenance About the refrigerant This product contains fluorinated greenhouse gases Do NOT ve...

Page 9: ...ers 2 1 3 Wash the air filters with water or clean them with a vacuum cleaner 4 Soak in lukewarm water for about 10 to 15 minutes INFORMATION If the dust does NOT come off easily wash them with a neut...

Page 10: ...s See 6 Maintenance and service 48 Check for open doors or windows Close doors and windows to prevent wind from coming in Check if the unit operates in Econo operation Refer to 4 3 6 Econo operation 4...

Page 11: ...e fault It is important to understand the problem and take measures before resetting the error code This should be done by a licensed installer or your local dealer To see the error code on the user i...

Page 12: ...TEMLER SAN T C A STANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P520336 3E 2...