background image

4 Operation

Operation manual

6

FTXF20~3 FTXF20~25B5V1B

Daikin room air conditioner

3P520336-3E – 2019.09

4.3.3

Airflow direction

When.

 Adjust the airflow direction as desired.

What.

  The  system  directs  the  airflow  differently,  depending  on  the

user selection (swinging or fixed position). It does so by moving the
vertical blades.

Setting

Airflow direction

 Vertical auto swing

Moves up and down.

[—]

Stays in a fixed position.

CAUTION

▪ ALWAYS use a user interface to adjust the angle of the

flap. When the flap is swinging and you move it forcibly
by hand, the mechanism will break.

▪ Be  careful  when  adjusting  the  louvers.  Inside  the  air

outlet, a fan is rotating at high speed.

Note:

  The  movable  range  of  the  flap  varies  according  to  the

operation  mode.  The  flap  will  stop  at  the  upper  position  when  the
airflow rate is changed to low during the up and down swing setting.

a

b

c

a

Flap range in cooling or drying operation

b

Flap range in heating operation

c

Flap range in fan only operation

To adjust the airflow direction

1

To use auto swing, press 

.

Result: 

 will appear on the LCD.

Result: 

The flap (horizontal blade) will begin to swing.

2

To  use  fixed  position,  press 

  when  the  flap  reaches  the

desired position.

Result: 

 disappears from the LCD.

To adjust the louvers (vertical blades)

1

Hold 1 or both knobs and move the louvers.

a

a

a

Knobs

INFORMATION

When  the  unit  is  installed  in  a  corner  of  a  room,  the
direction  of  the  louvers  should  be  facing  away  from  the
wall. Efficiency will drop if a wall blocks the air.

4.3.4

Comfort airflow operation

This operation can be used in 

heating

 or 

cooling

 operation mode. It

will provide a comfortable wind that will NOT come in direct contact
with people. The system automatically sets the fixed airflow position
upward in Cooling and downward in Heating operation mode.

Cooling operation mode

Heating operation mode

INFORMATION

Powerful and Comfort airflow operation CANNOT be used
at the same time. The last selected function takes priority.
If  the  vertical  automatic  swing  is  selected,  Comfort  airflow
operation will be cancelled.

To start/stop Comfort airflow operation

1

Press 

 to start.

Result: 

The  flap  position  will  change, 

  is  displayed  on  the

LCD, and the airflow rate is set to automatic.

Mode

Position of flap…

Cooling/Drying

Up

Heating

Down

2

Press 

 to stop.

Result: 

The  flap  will  return  to  the  position  from  before  the  Comfort

airflow mode; 

 disappears from the LCD.

4.3.5

Powerful operation

This  operation  quickly  maximizes  the  cooling/heating  effect  in  any
operation mode. You can get the maximum capacity.

INFORMATION

Powerful operation CANNOT be used together with Econo
and  Comfort  airflow  operation.  The  last  selected  function
takes priority.

Powerful  operation  will  NOT  increase  the  capacity  of  the
unit if it already operates at maximum capacity.

To start/stop Powerful operation

1

Press 

 to start.

Result: 

  is  displayed  on  the  LCD.  Powerful  operation  runs

for 20 minutes; after that, operation returns to the previously set
mode.

2

Press 

 to stop.

Result: 

 disappears from the LCD.

Note:

 Powerful operation can be set only when the unit is running. If

you  press 

,  operation  will  be  cancelled; 

  disappears

from the LCD.

Summary of Contents for FTXF20A5V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXF20A5V1B FTXF25A5V1B FTXF35A5V1B FTXF20B5V1B FTXF25B5V1B...

Page 2: ...ment Thank you for purchasing this product Please Keep the documentation for future reference Target audience End users INFORMATION This appliance is intended to be used by expert or trained users in...

Page 3: ...e disabled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other appliances or contact your in...

Page 4: ...Remove the back cover 2 Insert both batteries at once 3 Put the cover back 2 3 1 AAA LR03 3 3 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open an...

Page 5: ...or heating effect decreases when the outside temperature is too high or too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In th...

Page 6: ...drop if a wall blocks the air 4 3 4 Comfort airflow operation This operation can be used in heating or cooling operation mode It will provide a comfortable wind that will NOT come in direct contact wi...

Page 7: ...amp lights up INFORMATION Each time is pressed the time setting advances by 1 hour The timer can be set between 1 to 12 hours 2 Press to stop Result disappears from the LCD and the timer lamp goes off...

Page 8: ...ergy 6 Maintenance and service 6 1 Overview Maintenance and service The installer has to perform a yearly maintenance About the refrigerant This product contains fluorinated greenhouse gases Do NOT ve...

Page 9: ...ers 2 1 3 Wash the air filters with water or clean them with a vacuum cleaner 4 Soak in lukewarm water for about 10 to 15 minutes INFORMATION If the dust does NOT come off easily wash them with a neut...

Page 10: ...s See 6 Maintenance and service 48 Check for open doors or windows Close doors and windows to prevent wind from coming in Check if the unit operates in Econo operation Refer to 4 3 6 Econo operation 4...

Page 11: ...e fault It is important to understand the problem and take measures before resetting the error code This should be done by a licensed installer or your local dealer To see the error code on the user i...

Page 12: ...TEMLER SAN T C A STANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P520336 3E 2...

Reviews: