background image

3 Before operation

Operation manual

4

FTXF20~3 FTXF20~25B5V1B

Daikin room air conditioner

3P520336-3E – 2019.09

Icon

Description

Airflow rate = High

Airflow rate = Medium high

Airflow rate = Medium

Airflow rate = Medium low

Airflow rate = Low

Comfort operation is active

Auto vertical swing is active

ON timer is active

OFF timer is active

2.2.3

To operate the user interface

a

a

Signal receiver

1

Aim  the  signal  transmitter  at  the  signal  receiver  on  the  indoor
unit (maximum distance for communication is 7 m).

Result: 

When  the  indoor  unit  receives  a  signal  from  the  user

interface, you will hear a sound:

Sound

Description

Beep-beep

Operation starts.

Beep

Setting changes.

Long beep

Operation stops.

3

Before operation

3.1

To fix the user interface to the wall

b

c

a

a

User interface

b

Screws (field supply)

c

User interface holder

1

Choose a place where the signals reach the unit.

2

Attach the holder with screws to the wall or a similar location.

3

Hang the user interface on the user interface holder.

3.2

To insert the batteries

The batteries will last for about 1 year.

1

Remove the back cover.

2

Insert both batteries at once.

3

Put the cover back.

2

3

1

AAA.LR03

3.3

To turn on the power supply

1

Turn the circuit breaker on.

Result: 

The  flap  of  the  indoor  unit  will  open  and  close  to  set  the

reference position.

4

Operation

4.1

Operation range

Operation mode

Operation range

Cooling

(a)(b)

▪ Outdoor temperature: –10~46°C

▪ Indoor temperature: 18~32°C

▪ Indoor humidity: ≤80%

Heating

(a)

▪ Outdoor temperature: –15~24°C

▪ Indoor temperature: 10~30°C

Drying

(a)

▪ Outdoor temperature: –10~46°C

▪ Indoor temperature: 18~32°C

▪ Indoor humidity: ≤80%

If operated outside the operation range:

(a)

A safety device might stop the operation of the system.

(b)

Condensation might occur on the indoor unit and drip.

4.2

When to use which feature

You can use the following table to determine which features to use:

Feature

Tasks

Basic features

 Operation modes and

temperature

To start/stop the system and to set the
temperature:

▪ Heat up or cool down a room.

▪ Blow air in a room without heating or

cooling.

▪ Decrease the humidity in a room.

▪ In  Automatic  mode,  automatically

select  an  appropriate  temperature
and operation mode.

 Airflow direction

To adjust the airflow direction (swing or
fixed position).

 Airflow rate

To adjust the amount of air blown into
the room.

To run more quietly.

Advanced features

Summary of Contents for FTXF20A5V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXF20A5V1B FTXF25A5V1B FTXF35A5V1B FTXF20B5V1B FTXF25B5V1B...

Page 2: ...ment Thank you for purchasing this product Please Keep the documentation for future reference Target audience End users INFORMATION This appliance is intended to be used by expert or trained users in...

Page 3: ...e disabled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other appliances or contact your in...

Page 4: ...Remove the back cover 2 Insert both batteries at once 3 Put the cover back 2 3 1 AAA LR03 3 3 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open an...

Page 5: ...or heating effect decreases when the outside temperature is too high or too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In th...

Page 6: ...drop if a wall blocks the air 4 3 4 Comfort airflow operation This operation can be used in heating or cooling operation mode It will provide a comfortable wind that will NOT come in direct contact wi...

Page 7: ...amp lights up INFORMATION Each time is pressed the time setting advances by 1 hour The timer can be set between 1 to 12 hours 2 Press to stop Result disappears from the LCD and the timer lamp goes off...

Page 8: ...ergy 6 Maintenance and service 6 1 Overview Maintenance and service The installer has to perform a yearly maintenance About the refrigerant This product contains fluorinated greenhouse gases Do NOT ve...

Page 9: ...ers 2 1 3 Wash the air filters with water or clean them with a vacuum cleaner 4 Soak in lukewarm water for about 10 to 15 minutes INFORMATION If the dust does NOT come off easily wash them with a neut...

Page 10: ...s See 6 Maintenance and service 48 Check for open doors or windows Close doors and windows to prevent wind from coming in Check if the unit operates in Econo operation Refer to 4 3 6 Econo operation 4...

Page 11: ...e fault It is important to understand the problem and take measures before resetting the error code This should be done by a licensed installer or your local dealer To see the error code on the user i...

Page 12: ...TEMLER SAN T C A STANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P520336 3E 2...