Installation Tips

1.

Removing and installing the front panel

Removal method

1) Grip the panel tabs on each side of the front panel and open.
2) Slide the front panel to either the left or right and pull it toward you to 

disengage one of the front panel shafts.

3) Disengage the front panel shaft on the other side in the same manner.
4) After disengaging both front panel shafts, pull the front panel toward yourself and remove it.

Installation method

Align the front panel shaft of the front panel with the grooves of grille, and push 
all the way in, then close slowly. 
Push the center of the lower panel surface firmly to engage the tabs.

2.

Removing and installing the front grille

Removal method

1) Remove the front panel and air filters.
2) Remove 6 screws from the front grille.
3) Remove 3 front grille fixtures from the front grille.

4) In front of the 

 mark on the front grille, there are 4 upper 

hooks. Lightly pull the front grille toward you with one hand, and 
push down on the hooks with the fingers of your other hand.

When there is insufficient work space because the unit 
is close to ceiling

Place both hands under the center of the front grille, 
and while pushing up, pull it toward you.

Installation method

1) Install the front grille and firmly engage the upper hooks 

(4 locations).

2) Install 6 screws of the front grille.
3) Install 3 front grille fixtures of the front grille.
4) Install the air filters and then mount the front panel.

3.

How to set the different addresses

When 2 indoor units are installed in one room, the 2 wireless remote controllers can 
be set for different addresses. Change the address setting of one of the 2 units. 
When cutting the jumper, be careful not to damage any of the surrounding parts. 

1) Remove the front grille. (6 screws, 3 front grille fixtures)

2) Remove the metal plate electrical wiring box cover. (4 tabs) 

(See 

Fig.1

)

3) Cut the address jumper (JA) on the printed circuit board. 

(See 

Fig.2

)

4) Cut the address jumper (J4) in the remote controller. 

(See 

Fig.3

)

• Do not cut jumper (J8). (Jumper (J8) is cut to switch 

over the system to cooling only.)

5) Replace the metal electrical wiring box cover.

6) Replace the front grille.

4.

When connecting to an HA system

1) Remove the front grille. (6 screws, 3 front grille fixtures)

2) Remove the metal plate electrical wiring box cover. (4 tabs) (See 

Fig.1

)

3) Attach the connection cord to the S21 connector and pull the harness 

out through the notched part in the figure. (See 

Fig.4

)

4) Replace the electrical wiring box cover as it was, and pull the harness 

around, as shown in the figure. (See 

Fig.5

)

5) Replace the front grille.

Panel tab

Push the front panel 

shaft of the front panel 

into the groove.

Front panel shaft

Push

down.

Upper hook

 mark area 

(4 locations)

Be sure to wear protection 

gloves.

CAUTION

1) Push up.

2) Pull toward 

you.

Slide

Metal plate 

electrical 

wiring box 

cover

Main body

Pull

Pull

Slide

Slide

Tab

Fig.1

1
2

Jumper

(J8)

(J4)

ADDRESS

EXIST

CUT

Fig.2

Fig.3

ADDRESS

JA

ADDRESS

JA

EXIST

CUT

2

1

Fig.4

Fig.5

HA connector

(S21)

HA connector

(S21)

Lay the HA cord as 

shown in the figure.

01_EN_3P457790-1.fm  Page 9  Thursday, December 1, 2016  3:51 PM

Summary of Contents for FTX30NVJU

Page 1: ...INSTALLATION MANUAL DAIKIN ROOM AIR CONDITIONER R410A Split Series English Français Español MODELS FTX30NVJU FTX36NVJU Installation manual Manuel d installation Manual de instalación ...

Page 2: ...leak throughout the system Do not install unit in an area where flammable materials are present due to risk of explosions that can cause serious injury or death Safely dispose all packing and transportation materials in accordance with federal state local laws or ordinances Packing materials such as nails and other metal or wood parts including plastic packing materials used for transportation may...

Page 3: ...nted from getting into the system b Tight R410A does not contain any chlorine does not destroy the ozone layer and does not reduce the earth s protection again harmful ultraviolet radiation R410A can contribute to the greenhouse effect if it is released Therefore take proper measures to check for the tightness of the refrigerant piping installation Read the chapter Refrigerant Piping Work and foll...

Page 4: ...quipment is nearby 2 Wireless remote controller 1 Turn on all the fluorescent lamps in the room if any and find a location where the remote controller signals are properly received by the indoor unit within 23ft 7m 2 Configure the jumper Configure according to the type of unit heat pump or cooling only the user purchased The default setting is heat pump For heat pump outdoor unit model RX No chang...

Page 5: ...ters The service lid is removable Opening method 1 Remove the service lid screws 2 Pull out the service lid diagonally down in the direction of the arrow 3 Pull down Service lid Bottom of indoor unit Front grille fixture Screw covers 3 J Remote controller holder fixing screws M3 13 16 M3 20mm 2 F C Titanium apatite photocatalytic air purifying filter 3 Titanium apatite photocatalytic air purifying...

Page 6: ...using the markings at the top of the indoor unit as a guide 4 Open the front panel then open the service lid Refer to Service lid on page 4 5 Pass the inter unit wire from the outdoor unit through the feed through wall hole and then through the back of the indoor unit Pull them through the front side Bend the ends of tie wires upward for easier work in advance If the inter unit wire ends are to be...

Page 7: ...c shock or fire Do not use locally purchased electrical parts inside the product Do not branch the power for the drain pump etc from the terminal block Doing so may cause electric shock or fire Do not connect the power wire to the indoor unit Doing so may cause electric shock or fire 3 Switch around the drain hose and drain plug 1 Remove the fixing screw and pull out the drain hose How to switch a...

Page 8: ... embedded drain piping is required use appropriate parts that match the hose front end Figure of hose front end When drain hose requires extension obtain an extension hose with an inner diameter of 5 8 inch 16mm Be sure to thermally insulate the indoor section of the extension hose When connecting a rigid polyvinyl chloride pipe nominal diameter 1 2 inch 13mm directly to the drain hose attached to...

Page 9: ...thylene foam Heat transfer rate 0 041 to 0 052W mK 0 024 to 0 030Btu fth F 0 035 to 0 045kcal mh C Be sure to use insulation that is designed for use with HVAC Systems ACR Copper only Be sure to insulate both the gas and liquid piping and observe the insulation dimensions as below Use separate thermal insulation pipes for gas and liquid refrigerant pipes Piping size Minimum bend radius Piping thic...

Page 10: ...hen mount the front panel 3 How to set the different addresses When 2 indoor units are installed in one room the 2 wireless remote controllers can be set for different addresses Change the address setting of one of the 2 units When cutting the jumper be careful not to damage any of the surrounding parts 1 Remove the front grille 6 screws 3 front grille fixtures 2 Remove the metal plate electrical ...

Page 11: ... breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit breaker is opened again 2 Test items Test items Symptom Check Indoor and outdoor units are installed securely Fall vibration noise No refrigerant gas leaks Incomplete cooling heating function Refrigerant g...

Page 12: ... 1611 HT M16B117 The two dimensional bar code is a manufacturing code 3P457790 1 ...

Reviews: