Installation Tips

1.

Removing and installing the front panel

Removal method

Hook fingers on the tabs on the left and right of the main body, and open until the 
panel stops. Slide the front panel sideways to disengage the front panel shaft. 
Then pull the front panel toward you to remove it.

Installation method

Align the front panel shaft of the front panel with the grooves of grille, and push 
all the way in, then close slowly. 
Push the center of the lower panel surface firmly to engage the tabs.

2.

Removing and installing the front grille

Removal method

1) Remove the front panel and air filters.
2) Remove 6 screws from the front grille.

3) In front of the 

 mark on the front grille, there are 3 upper 

hooks. Lightly pull the front grille toward you with one hand, and 
push down on the hooks with the fingers of your other hand.

When there is insufficient work space because the unit 
is close to ceiling

Place both hands under the center of the front grille, 
and while pushing up, pull it toward you.

Installation method

1) Install the front grille and firmly engage the upper hooks 

(3 locations).

2) Install 6 screws of the front grille.
3) Install the air filters and then mount the front panel.

3.

How to set the different addresses

When 2 indoor units are installed in one room, the 2 wireless remote controllers can 
be set for different addresses. Change the address setting of one of the 2 units. 
When cutting the jumper, be careful not to damage any of the surrounding parts. 

1) Remove the front grille. (6 screws)

2) Remove the metal plate electrical wiring box cover. (4 tabs) 

(See 

Fig.1

)

3) Cut the address jumper (JA) on the printed circuit board. 

(See 

Fig.2

)

4) Cut the address jumper (J4) in the remote controller. 

(See 

Fig.3

)

• Do not cut jumper (J8).

5) Replace the metal electrical wiring box cover.

6) Replace the front grille.

4.

When connecting to an HA system

1) Remove the front grille. (6 screws)

2) Remove the metal plate electrical wiring box cover. (4 tabs) (See 

Fig.1

)

3) Attach the connection cord to the S21 connector and pull the harness 

out through the notched part in the figure. (See 

Fig.4

)

4) Replace the electrical wiring box cover as it was, and pull the harness 

around, as shown in the figure. (See 

Fig.5

)

5) Replace the front grille.

Push the front panel 

shaft of the front panel 

into the groove.

Front panel shaft

Push

down.

Upper hook

 mark area 

(3 locations)

•  Be sure to wear 

protection gloves.

CAUTION

1) Push up.

2) Pull toward 

you.

Slide

Metal plate 

electrical 

wiring box 

cover

Main body

Pull

Pull

Slide

Slide

Tab

Fig.1

1
2

Jumper

(J8)

(J4)

ADDRESS

EXIST

CUT

Fig.2

Fig.3

ADDRESS

JA

ADDRESS

JA

EXIST

CUT

2

1

Fig.4

Fig.5

HA connector

(S21)

HA connector

(S21)

Lay the HA cord as 

shown in the figure.

01_EN_3P572321-1A.fm  Page 9  Thursday, August 8, 2019  10:47 AM

Summary of Contents for FTX18UVJU

Page 1: ...INSTALLATION MANUAL DAIKIN ROOM AIR CONDITIONER R410A Split Series English Fran ais Espa ol MODELS FTX18UVJU FTX24UVJU Installation manual Manuel d installation Manual de instalaci n...

Page 2: ...eak throughout the system Do not install unit in an area where flammable materials are present due to risk of explosions that can cause serious injury or death Safely dispose all packing and transport...

Page 3: ...ented from getting into the system b Tight R410A does not contain any chlorine does not destroy the ozone layer and does not reduce the earth s protection again harmful ultraviolet radiation R410A can...

Page 4: ...is circulated throughout the room 8 the unit is away from electronic ignition type fluorescent lamps inverter or rapid start type as they may affect the remote controller range 9 no laundry equipment...

Page 5: ...ine Do not connect commercially available drain hose directly to the indoor unit Water leakage may result Caulk pipe hole gap with putty Front panel The service lid is removable Opening method 1 Remov...

Page 6: ...ss the drain hose and refrigerant pipes through the wall hole then position the indoor unit on the mounting plate hooks using the markings at the top of the indoor unit as a guide 4 Open the front pan...

Page 7: ...onnections as they may cause overheating electric shock or fire Do not use locally purchased electrical parts inside the product Do not branch the power for the drain pump etc from the terminal block...

Page 8: ...nsfer some water to the indoor heat exchanger by pouring water into the drain pan 3 Make sure that water flows out of the drain hose 4 If drain hose extension or embedded drain piping is required use...

Page 9: ...for use with HVAC Systems ACR Copper only Be sure to insulate both the gas and liquid piping and observe the insulation dimensions as below Use separate thermal insulation pipes for gas and liquid ref...

Page 10: ...en 2 indoor units are installed in one room the 2 wireless remote controllers can be set for different addresses Change the address setting of one of the 2 units When cutting the jumper be careful not...

Page 11: ...e used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut off the power to the air conditioner the system wil...

Page 12: ...1908 HT M18B295A The two dimensional bar code is a manufacturing code 3P572321 1A...

Reviews: