7
■
English
Indoor Unit Installation
3-2� Left-side, left-back, or left-bottom piping
How to replace the drain plug and drain hose
•
Replacing onto the left side
1) Remove the fixing screw of drain hose on the
right and remove the drain hose.
2) Remove the drain plug on the left side and
attach it to the right side.
3) Insert the drain hose and tighten with the
included fixing screw.
Forgetting to tighten this may cause water
leakages.
Drain hose attachment position
The drain hose is on the back of the unit.
Front side of unit
Attachment on the right side
(factory default)
Attachment on the left side
Drain hose
Fixing screw
Drain hose
Fixing screw
Right side
Left side
1) Attach the drain hose to the underside of the refrigerant
pipes with adhesive vinyl tape.
Remove pipe port cover here for left-bottom piping.
Left-bottom piping
Left-side
piping
Left-back
piping
Remove pipe
port cover here
for left-side
piping.
2) Be sure to connect the drain plug to the drain port in
place of without drain hose.
How to set the drain plug.
No gap.
Insert a hexagonal wrench (3/16 inch (4mm)).
Do not apply lubricating oil
(refrigerant oil) to the drain
plug when inserting it.
The application of
lubrication oil to the drain
plug will deteriorate the
plug to cause drain
leakage from the plug.
3) Shape the refrigerant pipes along the pipe
path marking on the
A
mounting plate.
4) Pass the drain hose and refrigerant pipes
through the wall hole, then position the indoor
unit on the
A
mounting plate hooks, using the
markings at the top of the indoor unit as a
guide.
5) Pull in the inter-unit wire.
6) Connect the inter-unit pipes.
Drain
hose
Caulk this hole
with putty or
caulking material.
Bind with adhesive
vinyl tape.
Mounting plate
Wrap insulation tape around
the bent portion of the refrigerant
pipes.
Overlap at least half the width of
the tape with each turn.
J
A
7) In case of pulling the drain hose through the back of the
indoor unit, wrap the refrigerant pipes and drain hose
together with
J
insulation tape as shown in the right
figure.
8) To confirm that the inter-unit wire does not catch by
the indoor unit, press the bottom edge of the indoor
unit with both hands until it is firmly caught by the
A
mounting plate hooks. Secure the indoor unit to the
A
mounting plate with the
H
indoor unit fixing screws
3/16” × 1/2” (M4 × 12mm).
H
A
Refrigerant
pipes
Drain hose
Bottom frame
Indoor unit fixing screw
3/16” × 1/2” (M4 × 12mm)
Mounting
plate
Inter-unit wire
3-3� Wall embedded piping
Follow the instructions given under left-side, left-back, or
left-bottom piping.
1) Insert the drain hose to this depth so it won’t be pulled
out of the drain pipe.
Inner wall
Vinyl chloride
drain pipe
(VP-30)
Drain hose
1-15/16”
(50mm)
Insert drain hose
to this depth so
it won’t be pulled
out of drain pipe.
Outer wall
01_EN_3P379970-1.indd 7
10/17/2014 12:57:24 PM