• Split Sky Air • Indoor Units

4

• Indoor Units • R-410A • FTX-GV1B

3

Dimensional drawing & centre of gravity

3 - 1

Dimensional drawing

FTX20-35GV

3D058481

The mark (

) shows piping direction   

Front panel fixing screws ( Inside)

Signal receiver

Operation lamp

Timer lamp

Indoor unit ON/OFF switch

Room temp. thermistor (Inside)

Rear

Air flow (Indoor)

(Spac

e for

 perfo

rmanc

e)

Terminal block 
with earth 
terminal 
(Inside) 

General rating 
name plate

Model name plate

Bottom

Signal transmitter

Right

Flaps

Up/down (Automatic)

Fan

Heating

Dry

Right/left (Manual)

50Min.
(Space for maintenance)

50Min.

(Space for maintenance)

30Mi

n.

Including 

mounting plate

Gas pipe Ø

 

9,5 Cut

(The length of pipe outside the unit: 
About 400)

Liquid pipe Ø

 

6,4 Cut

(The length of pipe outside 
the unit: About 400)

Drain hose
( Connecting part 
I.D.  Ø

 

14

O.D.  Ø

 

16

The hose length of ouside the unit is about 450)

Wall hole for embedded piping

Ø

 

65 Hole

Wall hole

Ø

 

65 Hole

Left

STANDARD LOCATIONS OF WALL HOLES

INFRARED REMOTE CONTROL

(ARC433A89)

BLADE ANGLE

REQUIRED SPACE

Cooling

Summary of Contents for FTX-GV1B

Page 1: ...an non inverter units Dual air discharge flow for better air distribution ECONO mode decreases power consumption so that other appliances that need large power supply can be used Indoor unit On Off sw...

Page 2: ...Fan Type Cross flow fan Quantity 1 1 1 Air Flow Rate Cooling High m min 9 1 9 2 9 3 Medium m min 7 4 7 6 7 7 Low m min 5 9 6 0 6 1 Silent Operation m min 4 7 4 8 4 9 Heating High m min 9 4 9 7 10 1 M...

Page 3: ...irection control Right Left Horizontal Downward Temperature control Microcomputer control Standard Accessories Item Installation manual Quantity 1 1 1 Item Operation manual Quantity 1 1 1 Item Wireles...

Page 4: ...eral rating name plate Model name plate Bottom Signal transmitter Right Flaps Up down Automatic Fan Heating Dry Right left Manual 50Min Space for maintenance 50Min Space for maintenance 30Min Includin...

Page 5: ...Indoor Units R 410A FTX GV1B 1 3 Split Sky Air Indoor Units 5 3 Dimensional drawing centre of gravity 3 2 Centre of gravity FTX20 35GV 4D059099...

Page 6: ...410A FTX GV1B 4 Piping diagram FTX20 35GV 4D058926 Refrigerant flow Heat exchanger Fan motor Cross flow fan Thermistor on heat exch 9 5 Cut INDOOR UNIT Field piping 9 5Cut Field piping 6 4Cut 7 0 Cut...

Page 7: ...r Swing motor Printed circuit board Thermistor Connector Operation switch Terminal strip Protective earth CAUTION Note that operation will restart automaticallyifthemainpower supply is turned off and...

Page 8: ...e band sound pressure level dB 0dB 0 0002 bar Approximate threshold hearing for continuous noise FTX20GV HEATING 1m 0 8m Octave band center frequency Hz 3D058956 NOTES 1 Operating conditons 230V 50Hz...

Page 9: ...band sound pressure level dB 0dB 0 0002 bar Approximate threshold hearing for continuous noise FTX35GV COOLING 1m 0 8m Octave band center frequency Hz 3D058957 NOTES 1 Operating conditons 230V 50Hz 5...

Reviews: