![background image](http://html1.mh-extra.com/html/daikin/ftks09jv2s/ftks09jv2s_service-manual_3400909013.webp)
Si041252EE
PCBs
Removal Procedure
11
3
Remove the signal
receiver unit.
3. Remove the
INTELLIGENT EYE
sensor PCB.
1
2
Unfasten the 3 hooks
and remove the
INTELLIGENT EYE
sensor PCB.
Disconnect the
connector [S26].
4. Remove the signal
receiver PCB.
1
2
Unfasten the 3 hooks
and remove the signal
receiver PCB.
Disconnect the
connector [S48].
Step
Procedure
Points
(R8088)
Signal receiver unit
(R21138)
INTELLIGENT EYE
sensor PCB
[S26]
Hook
Hook
(R21139)
Signal
receiver
PCB
[S48]
Hook
Hook