background image

Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan

Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/products/ac/

All rights reserved

c

Warning

z

Daikin products are manufactured for export to numerous countries throughout the world. Prior to 
purchase, please confirm with your local authorised importer, distributor and/or retailer whether this 
product conforms to the applicable standards, and is suitable for use, in the region where the product 
will be used. This statement does not purport to exclude, restrict or modify the application of any local 
legislation.

z

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. 
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

z

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or 
contractor to install those parts and accessories. Use of unauthorised parts and accessories or 
improper installation of parts and accessories can result in water or refrigerant leakage, electrical 
shock, fire or explosion.

z

Read the user's manual carefully before using this product. The user's manual provides important 
safety instructions and warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install 

the outdoor unit close to the sea shore, contact your local distributor.

Dealer

z

Specifications, designs and other content appearing in this brochure are current as of August 2015 but subject to change without notice.

Si041252EE

08/2015 AK.B

Summary of Contents for FTKS09JV2S

Page 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L Indoor Unit Inverter Wall Mounted Type 2 0 2 2 2 5 2 8 3 5 3 6 4 1 4 2 4 6 5 0 kW Class 7000 9000 12000 15000 Btu h Class Si041252EE...

Page 2: ...B FTKS35KVMA CTXS07LVJU FTKS22MVLT FTXS09LVJU FTKS28MVLT FTXS12LVJU FTKS36MVLT FTXS20KVMA FTKM09NV2S FTXS25KVMA FTKM12NV2S FTXS35KVMA FTKM15NV2S FTXS22MVLT FTKM25NVM FTXS28MVLT FTKM35NVM FTXS36MVLT FT...

Page 3: ...r Filters 2 2 Front Panel 3 3 Front Grille 4 4 Horizontal Blades 5 5 Vertical Blade ASSYs 6 6 Electrical Box 8 7 PCBs 10 8 Swing Motors 13 9 Indoor Heat Exchanger 16 10 Fan Motor 18 Note The illustrat...

Page 4: ...panel 2 for each filter Pull out the air filter downward and remove it 2 Remove the Titanium apatite photocatalytic air purifying filters 1 Remove the Titanium apatite photocatalytic air purifying fil...

Page 5: ...e Points 1 Open the front panel over the position where it stops 2 3 4 Slide the front panel to the right and release the left rotary shaft Release the right rotary shaft in the same way Remove the fr...

Page 6: ...ve the screw and remove the service cover 2 3 Remove the 2 screws Unfasten the 3 hooks at the top The convex marks on the front grille indicate the position of the hooks 4 Pull out the upper part of t...

Page 7: ...ng mount the large horizontal blade to the upper position and the small horizontal blade to the lower position Do not put them in the wrong place 2 Release the left shaft 3 4 Release the right shaft a...

Page 8: ...an guards Some models have no fan guard 1 Unfasten the 2 hooks at the lower part of the fan guard with a flat screwdriver 2 3 Remove the fan guard Remove the other fan guard in the same way 2 Remove t...

Page 9: ...th a flat screwdriver 4 5 Remove the vertical blade ASSY Remove the other vertical blade ASSY in the same way Each vertical blade ASSY has 5 fins It is impossible to replace only one fin The vertical...

Page 10: ...disconnect the connecting wire For U S models When reassembling make sure that the connecting wire is passed through the conduit hole at the bottom of the unit 3 Disconnect the connector S1 S1 fan mo...

Page 11: ...tor 7 8 Remove the screw and detach the earth ground wire Remove the screw of the electrical box 9 Lift up the electrical box and pull it out Unfasten the hook at the back There is a hook also at the...

Page 12: ...The figure shows the parts of the electrical box 2 3 4 Unfasten the 2 hooks upper Unfasten the hook back Lift up the shield plate to unfasten the 2 hooks lower 2 Remove the signal receiver unit 1 Unf...

Page 13: ...ks and remove the INTELLIGENT EYE sensor PCB Disconnect the connector S26 4 Remove the signal receiver PCB 1 2 Unfasten the 3 hooks and remove the signal receiver PCB Disconnect the connector S48 Step...

Page 14: ...play PCB 2 Disconnect the connector S49 S49 control PCB 6 Remove the control PCB 1 Unfasten the 2 lower hooks of the control PCB 2 Lift up the bottom of the control PCB and pull it out The control PCB...

Page 15: ...ove the swing motor for vertical blades Lift the indoor unit with a wooden base for easy work Use the short screwdriver from the back 1 Remove the screw behind the drain hose and disconnect the drain...

Page 16: ...otor with a flat screwdriver 6 Remove the vertical blade interlock with a flat screwdriver 7 Remove the 2 screws and remove the swing motor for vertical blades Step Procedure Points R21144 Swing motor...

Page 17: ...motor for the upper blade first connector white 2 Then set the swing motor for the lower blade connector red 3 Fix the 2 swing motors with 1 screw 1 Remove the screw and remove the swing motors for h...

Page 18: ...om the unit After conducting vacuum drying recharge proper amount of refrigerant From the viewpoint of global environmental protection make sure to use a vacuum pump for air purging Step Procedure Poi...

Page 19: ...h a flat screwdriver 6 After unfastening the lower hook lift up the indoor heat exchanger by its right side When reassembling the indoor heat exchanger make sure that the right hooks upper and lower a...

Page 20: ...between the side face of the rotor and the bottom frame 1 Insert the fan motor with approx 5 mm 0 2 inch left 2 Tighten the screw until it stops Then turn the screw in one scroll 3 Move the fan rotor...

Page 21: ...on ATXS20 25 35 42 50G2V1B 04 2013 Si041252_B Model addition FTKS09 12JV2S FTK X S22 28 36MVLT CTXS07LVJU FTXS09 12LVJU 06 2014 Si041252EC Model addition FTKM09 12 15NV2S FTKM25 35 42NVM 12 2014 Si041...

Page 22: ...ries supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and acce...