![background image](http://html1.mh-extra.com/html/daikin/ftks09jv2s/ftks09jv2s_service-manual_3400909010.webp)
Electrical Box
Si041252EE
8
Removal Procedure
6. Electrical Box
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
2
Remove the screw and
remove the wire fixture.
Remove the 4 screws
on the terminal board
and disconnect the
connecting wire.
For U.S. models
When reassembling, make
sure that the connecting wire
is passed through the
conduit hole at the bottom of
the unit.
3
Disconnect the
connector [S1].
[S1]: fan motor
4
Disconnect the
connector [S41].
[S41]: swing motors
5
Release the harness for
the swing motors from
the hook.
When reassembling, be sure
to put the harness for the
swing motors behind the
hook.
(R18696)
Electrical box
Wire
fixture
Terminal
board
Connecting
wire
(R13499)
[S1]
(R18694)
[S41]
(R18695)
Hook