Si041352ED
Fan Motor (Without Removing Indoor Heat Exchanger)
Removal Procedure
23
5
Remove the fan motor
fixing plate (lower).
When reassembling the fan
motor and the fan rotor,
provide as much as 5 mm
(0.2 inch) of play between
the side face of the rotor and
the bottom frame.
(1) Insert the fan motor allowing
for approx. 5 mm (0.2 inch)
of play.
(2) Tighten the fan rotor screw
until it stops. Then give the
screw one more turn.
(3) If the fan rotor rotates
appropriately, tighten the
screw completely.
(4) If not, repeat the procedure
from (1).
6
Remove the fan motor.
7
Remove the vibration
absorber.
When reassembling, engage
the vibration absorber
completely.
Step
Procedure
Points
(R9564)
5 mm (0.2 inch)
Side face of rotor
(R18879)
Side face of
bottom frame
(R9582)
(R9565)
Fan motor
(R9567)
(R9566)
Vibration
absorber