Si041352ED
Electrical Box
Removal Procedure
7
4
Pull out the indoor heat
exchanger thermistor.
The position of the indoor
heat exchanger thermistor
varies depending on the
model.
Some models have a clamp
fixing the indoor heat
exchanger thermistor to the
indoor heat exchanger.
Cut the clamp, if any.
Be careful not to lose the clip
of the thermistor.
5
6
Remove the screw, and
then the wire fixture.
Remove the 4 screws
on the terminal strip
and disconnect the
connecting wire.
7
Disconnect the
connector [S1] and
release the harness
from the hook.
[S1]: fan motor
For U.S. models
When reassembling, make
sure that the connecting wire
is passed through the
conduit hole at the bottom of
the unit
8
Release the ferrite core.
Step
Procedure
Points
1 2
3
Indoor heat exchanger thermistor
(R22045)
(R22132)
Clamp
Clip
(R11268)
1 2
3
Terminal strip
Wire
fixture
Connecting wire
(R24478)
1 2
3
(R18716)
[S1]
Hook
Lock nut
Back
Conduit
Conduit mounting
plate
(R24421)
(R9501)
Ferrite core