background image

16

Detach the
filter element
and attach a
new one.

Set the air
filters as they
were and
close the front
grille.

(Push the grille
at the 4 points,
two at both sides
and in the
middle.)

5

Air filter

Air purifying

filter frame

• 

Hold the recessed 
parts of the frame 
and unhook the four 
claws.

Before cleaning, be sure to stop the
operation and turn the breaker OFF.

Open the front grille.

Hold the grille by the tabs on the two sides
and lift it unitl it stops with a click. (about 60°)

Pull out the air filters.

Push a little upwards the
tab at the center of each
air filter, then pull it down.

1

3

2

Take off the air purifying filters and
clean them.

Wash them with

water, or clean them

with a vacuum

cleaner.

If the dust does not

come off easily, wash

them with neutral

detergent thinned

with lukewarm water,

then dry them up in the shade.

Set the air purifying filters and the
air filters as they were and close the
front grille.

4

(It is recommended to clean them every two weeks.)

Open the front grille and pull out
the air filters.

Take off the air
purifying filters.

Wipe them with dry soft cloth.
For cleaning, do not use water hotter than
40°C, benzine, gasoline, thinner, nor other
volatile oils, polishing compound, scrubbing
brushes nor other hard stuff.

(It is recommended to replace them every
three months.)

Air purifying filters need to be replaced regularly.

Attach the air
purifying filter.

Care and Cleaning

CAUTION

NOTE

Insert claws of the filters into slots of the front
panel. The front grille should lock at both
sides and at the point in the middle. Push the
grille at the 4 points indicated by   .

Push

In a dusty environment, clean the air filters

at least once in every two weeks.

Operation with dusty air filters lowers the

cooling and heating capacity and wastes

energy.

NOTE

To order air purifying filters, contact the
service shop where you bought the air
conditioner.

Once the air purifying filter element gets
dirty, it is not reusable but must be thrown
away.

Operation with dirty air purifying filters :
• cannot clean the air.
• results in poor cooling.
• may cause odour.

Cleaning the indoor and outdoor
units and the remote controller

Replacing air purifying filters

Item

Air purifying filter (with frame)
Air purifying filter (without frame)

Part No.

KAF918A41
KAF918A42

4

1

3

2

Cleaning the air filters

01̲EN̲3P059682-3R-2.p65

07/05/26, 17:10

Page 16

Adobe PageMaker 6.5J/Win

Summary of Contents for FTKD50JVET

Page 1: ...ENGLISH P1 P20 21 41 DAIKIN ROOM AIR CONDITIONER DAIKIN FTKD50JVET FTXD50JVET FTKD60JVET FTXD60JVET FTKD71JVET FTXD71JVET Operation Manual MODELS...

Page 2: ...lap 11 Adjusting the vertical blade louvre 11 POWERFUL Operation 12 OUTDOOR UNIT SILENT Operation 12 HOME LEAVE Operation 13 Timer Operation OFF TIMER operation 15 ON TIMER operation 15 CARE Care and...

Page 3: ...heck with a qualified repairman before attempting any repairs which might accompany addition of refrigerant The refrigerant used in the air conditioner is safe Although leaks should not occur if for s...

Page 4: ...WARNING CAUTION Installation Do not stand or sit on the outdoor unit Do not place any object on the unit The object or the person may fall down or drop causing injury Do not place under the indoor or...

Page 5: ...on will automatically start and operate in the mode in which a previously operated indoor unit was stopped However if the unit in operation provides only COOL and DRY modes simultaneous operation is p...

Page 6: ...is on the fan may rotate inside and may cause injury CAUTION Receiver FTKD COOL Mode 22 C Temperature setting AUTO FTXD AUTO 25 C AUTO Air flow rate DAIKIN Front grille Indicator lamps Grille tab Dif...

Page 7: ...etting button It selects the air flow rate setting SWING buttons See page 11 It changes the temperature or time setting Display It displays the current settings In this illustration each section is sh...

Page 8: ...earance of the outdoor unit may differ with some models Refrigerant piping and inter unit cable Air outlet Air inlet Earth terminal It is inside of this part Drain hose Names of Parts RKD RXD Air inle...

Page 9: ...aximum distance for communication is about 7 m About the remote controller Never expose the remote controller to direct sunlight Dust on the signal transmitter or receiver will reduce the sensitivity...

Page 10: ...ach an air purifying filter to each air filter See page 16 Care and cleaning Set the air filters in their original positions and close the front grille Operation without air filters may result in trou...

Page 11: ...NOTE Note on HEAT mode operation Since this air conditioner heats the room by taking heat from outdoor air to indoors the heating capacity becomes smaller in lower outdoor temperatures If the heating...

Page 12: ...nd when it is swinging the mechanism may be broken Notes on flap angles Adjusting the vertical blade louvre Press Every time the button is pressed appears or disappears The flap automatically swings u...

Page 13: ...ghtly increased In FAN mode The air flow rate is fixed to the maximum set ting OUTDOOR UNIT SILENT Operation OUTDOOR UNIT SILENT Operation lowers the noise level of the outdoor unit by changing the fr...

Page 14: ...2 3 Adjust the air flow rate setting with FAN as you like The temperature and air flow rate will be the same as the previous settings starting with the second use If you want to change the settings fr...

Page 15: ...l operation Even the coldest winters will pose no problem NOTE Note on HOME LEAVE Operation HOME LEAVE Operation is only available in COOL and HEAT modes Cannot be used in AUTO DRY and FAN modes HOME...

Page 16: ...ditioner is not operating Press ON TIMER once again Check that the clock is correct If not set the clock to the present time See page 9 1 is displayed blinks 2 Press until the time setting reaches the...

Page 17: ...filters Wipe them with dry soft cloth For cleaning do not use water hotter than 40 C benzine gasoline thinner nor other volatile oils polishing compound scrubbing brushes nor other hard stuff It is re...

Page 18: ...e front grille with one hand fit the lock by sliding up the knob with the other hand Close the front grille slowly in this state Push the grille at the 3 points two at both sides and in the middle Ope...

Page 19: ...e system is taking away the frost on the outdoor unit You should wait for about 3 to 10 minutes In HEAT mode The frost on the outdoor unit melts into water or steam when the air conditioner is in defr...

Page 20: ...air inlet or the outlet of the indoor and the outdoor units Clean the air filters or take all obstacles away and turn the breaker OFF Then turn it ON again and try operating the air conditioner with t...

Page 21: ...or the earth leakage breaker cuts off the operation frequently A switch or a button often fails to work properly There is a burning smell Water leaks from the indoor unit Turn the breaker OFF and call...

Page 22: ...3P059682 3R M00B005A 0706 HT Two dimensional bar code is a code for manufacturing...