![background image](http://html1.mh-extra.com/html/daikin/ftkd24hv2s/ftkd24hv2s_service-manual_4219253015.webp)
Si041144
Removal of PCBs
Removal Procedure
13
7
Release the harness
from the hook.
When reassembling, make
sure to hook the harness.
8
Push and unfasten the
hook of the signal
receiver unit.
9
Open the signal
receiver unit.
Unfasten the hook and
remove the signal
receiver unit.
Step
Procedure
Points
(R9514)
Hook
(R16512)
Hook
Signal
receiver
unit
(R16500)
Hook