![background image](http://html1.mh-extra.com/html/daikin/ftkd24hv2s/ftkd24hv2s_service-manual_4219253033.webp)
Si041144
Removal of Fan Motor / Fan Rotor
Removal Procedure
31
7. Removal of Fan Motor / Fan Rotor
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Remove the right side
plate.
1
Remove the 2 screws.
2
Lift the right side plate
and remove it.
2. Remove the fan rotor.
1
Remove the screw of
the fan motor fixing
plate and remove it.
(R16306)
Right side plate
(R16307)
(R16972)
Fan motor
fixing plate