![background image](http://html1.mh-extra.com/html/daikin/ft20fv1m/ft20fv1m_installation-manual_2459305012.webp)
10
INSTALLATION OF UNIT WITH O2 THERAPY FEATURE
3. Insert the end hose to the connector (indoor)
Refrigerant Piping
2. Insert the end hose to the connector (outdoor)
1. Open valve cover to connecting the
O
2
hose
O
2
Hose
Maintenance Procedures
1. Remove any dust adhering to the filter by using a vacuum cleaner or wash in
lukewarm water (below 40°C/104°F) with a neutral cleaning detergent.
2. Rinse the filter well and dry before placing it back onto the unit.
3. Do not use gasoline, volatile substances or chemicals to clean the filter.
1. Clean any dirt or dust on the grille or panel by wiping it with a soft cloth
soaked in lukewarm water (below 40°C/104°F) and a neutral detergent
solution.
2. Do not use gasoline, volatile substances or chemicals to clean the
indoor unit.
Period
At least once
every 2 weeks.
More frequently if
necessary.
At least once
every 2 weeks.
More frequently if
necessary.
Service Parts
Indoor air filter
Indoor unit
SERVICE AND MAINTENANCE
!
WARNING
•
Disconnect from the main power supply before servicing the air conditioner unit.
•
DO NOT pull out the power cord when the power is ON. This may cause serious electrical shocks which may result
in fire hazards.
If there is a power cut when the unit is operating, it will automatically resume the same operating mode when the power is
restored.
!
CAUTION
Before turning off the power supply, set the remote controller’s ON/OFF switch to the “OFF” position to prevent the nuisance
tripping of the unit.
If this is not done, the unit’s fans will start turning automatically when power resumes, posing a hazard to service personnel or the
user.
AUTO RANDOM RE-START FUNCTION