8

Preparation Before Operation

Setting the air purifying filters

Indoor unit

Holding down ( 

 ) or ( 

 ) button

rapidly increases or decreases the time display.

Setting the clock

Press 

 .

Press 

TIMER

 to set the clock to the present

time.

Turn the breaker ON

Turning ON the breaker opens the flap, then
closes it again. (This is a normal procedure.)

Pull out the air filters.

Push upwards the
tab at the center of
each air filter, then
pull it down.

2

Open the front grille.

Hold the grille by the tabs on the two sides
and lift it until it stops with a click.
(about 60°)

1

Set the air purifying filters.

Attach an air purifying filter to each air filter.
(See page 12 “Care and cleaning”)

Set the air filters in their original
positions and close the front grille.

Operation without air filters may result in
troubles as dust will accumulate inside the
indoor unit.

3

4

1

AM

 is displayed.

2

AM

Display

 blinks.

3

Press 

 .

 blinks.

(Now the clock is set.)

PM

Display

PM

Display

NOTE

Please note

The air conditioner always consumes 7 watts of
electricity even while it is not operating.

If you are not going to use the air conditioner for
a long period, for example in spring or autumn,
turn the breaker OFF.

Use the air conditioner in the following
conditions.

Mode

COOL

HEAT

DRY

Operating conditions

Outdoor temperature : 19 to 46 °C
Indoor temperature

: 18 to 32 °C

Indoor humidity

: 80% max.

 

Outdoor temperature : –10 to 21 °C
Indoor temperature

: 27 °C max.

Outdoor temperature : 19 to 46 °C
Indoor temperature

: 18 to 32 °C

Indoor humidity

: 80% max.

If operation is continued out of this range

A safety device may work to stop the operation.
(In multi system, it may work to stop
the operation of the outdoor unit only.)

Condensation may occur on the indoor unit and drip.

A safety device may work to stop the operation.

A safety device may work to stop the operation.

Condensation may occur on the indoor unit and drip.

Tips for saving energy

Be careful not to cool the room too much.
Keeping the temperature setting at a
moderate level helps save energy.

Recommended temperature setting

For cooling: 26°C – 28°C
For heating: 20°C – 24°C

Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors
increases the cooling effect.

Clogged air filters cause inefficient
operation and waste energy.  Clean them
once in about every two weeks.

Summary of Contents for FT18JV1B

Page 1: ...FT18JV1B FTY18JV1B FT25JV1B FTY22JV1B FT35JV1B FTY35JV1B Operation Manual MODELS DAIKIN ROOM AIR CONDITIONER ENGLISH DEUTSCH FRAN AIS NEDERLANDS ESPA OL ITALIANO E HNIKA PORTUGUES DANSK NORSK SUOMI...

Page 2: ...e flap 10 Adjusting the vertical blade louvre 10 POWERFUL Operation 10 Timer Operation OFF TIMER operation 11 ON TIMER operation 11 CARE Care and Cleaning Cleaning the air filters 12 Cleaning the indo...

Page 3: ...ere the unit was purchased Check with a qualified repairman before attempting any repairs which might accompany addition of refrigerant The refrigerant used in the air conditioner is safe Although lea...

Page 4: ...g may result in injury Installation WARNING Do not attempt to install the air conditioner by yourself Consult the service shop or a qualified technician Incorrect work will result in water leakage ele...

Page 5: ...neighbours from noises For installation choose a place as described below A place solid enough to bear the weight of the unit which does not amplify the operation noise or vibration A place from wher...

Page 6: ...nals from the remote controller When the unit receives a signal you will hear a short beep Before opening the front grille be sure to stop the operation and turn the breaker OFF If the power is on the...

Page 7: ...ation each section is shown with all its displays ON for the purpose of explanation Some models may not show all its indications ON TIMER button See page 11 TIMER Setting button It changes the time se...

Page 8: ...the remote controller aim the transmitter at the indoor unit If there is anything to block signals between the unit and the remote controller such as a curtain the unit will not operate Do not drop th...

Page 9: ...while it is not operating If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker OFF Use the air conditioner in the following conditions Mo...

Page 10: ...tion Since this air conditioner heats the room by taking heat from outdoor air to indoors the heating capacity becomes smaller in lower outdoor temperatures If the heating effect is insufficient it is...

Page 11: ...ting Display Press ON No display Adjusting the Air Flow Direction You can adjust the air flow direction to increase your comfort Adjusting the horizontal blade flap To stop the flap at an angle you li...

Page 12: ...cancel the timer Then the TIMER lamp goes off Check that the clock is correct If not set the clock to the present time See page 8 1 is displayed blinks Previous time setting appears on display 2 Press...

Page 13: ...s Take off the air purifying filters Wipe them with dry soft cloth For cleaning do not use water hotter than 40 C benzine gasoline thinner nor other volatile oils polishing compound scrubbing brushes...

Page 14: ...and push them in all the way Supporting the front grille with one hand fit the lock by sliding up the knob with the other hand Close the front grille slowly in this state Push the grille at the 3 poin...

Page 15: ...e system is taking away the frost on the outdoor unit You should wait for about 3 to 10 minutes In HEAT mode The frost on the outdoor unit melts into water or steam when the air conditioner is in defr...

Page 16: ...Is the temperature setting appropriate Are the windows and doors closed Are the air flow rate and the air direction set appropriately Are the air filters clean Is there anything to block the air inle...

Page 17: ...ails to work properly There is a burning smell Water leaks from the indoor unit Turn the breaker OFF and call the service shop After a power failure The air conditioner automatically resumes operation...

Page 18: ...TOR OR STOPPED BY HIGH PRESSURE CONTROL FAN MOTOR FAULT FAULTY HEAT EXCHANGER SENSOR FAULTY SUCTION AIR TEMPERATURE SENSOR CODE 00 U0 U2 U4 U5 A5 A6 C4 OR C5 C9 SYSTEM INDOOR UNIT MEANING INTERNAL THE...