![Daikin FLXS-BAVMB Service Manual Download Page 156](http://html.mh-extra.com/html/daikin/flxs-bavmb/flxs-bavmb_service-manual_502275156.webp)
Outdoor Unit - RK(X)S25/35E2V1B
SiBE05-722_B
145
Removal Procedure
2.3
Removal of PCB
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Feature of the main
PCB
You can remove the main
PCB when you disconnect
the lead wires on the
terminal board without
removing the electrical box.
2
Remove the screw on
the terminal board.
3
Release the 2 earth
terminals.
(R7255)
(R7256)
Terminal
board
(R7257)
Earth
terminal