SiBE05-722_B
Indoor Unit
Removal Procedure
122
1.3
Removal of Horizontal Blade
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Open the horizontal
blade.
2
Deflect the 3 center
bearings to the left side
slightly, and release the
shafts of the horizontal
blade.
3
Bend the horizontal
blade slightly to release
the shafts from
bearings at the both
ends. (Release the left
side shaft first.)
Horizontal blade
(1)
(2)