NOMINAL CAPACITY and NOMINAL INPUT
For indoor units only:
INDOOR UNITS
FHYP71BV1
FHYP100BV1
FHYP125BV1
NOMINAL INPUT
Cooling
kW
0.117
0.135
0.144
For combination indoor units + outdoor units:
INDOOR UNITS
FHYP71BV1
FHYP100BV1
FHYP125BV1
OUTDOOR UNITS
RP71B7V1/W1/T1
RP100B7V1/W1/T1
RP125B7W1/T1
NOMINAL CAPACITY
(2)
Cooling (1)
kW
7.1/7.1/7.1
10.0/10.0/10.0
12.5/12.5
NOMINAL INPUT
Cooling
kW
2.65/2.61/2.61
3.82/3.62/3.62
4.69/4.69
TECHNICAL SPECIFICATIONS
For indoor units only:
INDOOR UNITS
FHYP71BV1
FHYP100BV1
FHYP125BV1
DIMENSIONS
Unit
H
mm
195
195
195
W
mm
1,160
1,400
1,590
D
mm
680
680
680
WEIGHT
Unit
kg
27
32
35
MATERIAL
Unit
-
-
-
COLOUR
Unit
White
SOUND LEVEL
Sound pressure (3)
high
dB(A)
39
42
44
low
dB(A)
35
37
39
Sound power (4)
high
dB(A)
55
58
60
low
dB(A)
51
53
55
FAN
Air flow rate
(cooling)
high
m
3
/min
17
24
30
medium
m
3
/min
-
-
-
low
m
3
/min
14
20
25
Speed
steps
2 steps
2 steps
2 steps
high
rpm
-
-
-
low
rpm
-
-
-
Type
Sirocco fan
Qty x model
1 x 4D12K1AA1
1 x 3D12K2AA1
1 x 4D12K2AA1
Qty x motor output
W
1 x 62
1 x 130
1 x 130
HEAT EXCHANGER
Type
Cross fin coil (Multi louver fins and N-HiX tubes)
Rows x stages x fin pitch
mm
3 x 12 x 1.75
3 x 12 x 1.75
3 x 12 x 1.75
Face area
m
2
0.233
0.293
0.341
AIR FILTER
-
-
-
AIR DIRECTION CONTROL
-
-
-
TEMPERATURE CONTROL
-
-
-
PIPING CONNECTIONS
liquid
mm
φ
9.5 (flare)
φ
9.5 (flare)
φ
9.5 (flare)
gas
mm
φ
15.9 (flare)
φ
19.1 (flare)
φ
19.1 (flare)
Drain
mm
VP20 (I.D.
φ
20)
VP20 (I.D.
φ
20)
VP20 (I.D.
φ
20)
Drain
mm
VP20 (O.D.
φ
26)
VP20 (O.D.
φ
26)
VP20 (O.D.
φ
26)
INSULATION
MATERIAL
Heat insulation
Foamed polystyrene / Foamed polyethylene
Sound absorbing insulation
Foamed polyurethane/Glass wool
For outdoor units
only:
Pair application
See chapter R-GZ7/RP-B7
•
Ceiling Suspended Unit
•
R-407C
•
FH(Y)-GZ/BZ/FHYP-B
2
Specifications
10
2
4
•
Split - Sky Air
•
Indoor Units