Dimensional drawings
Model
A
FH35GZ
12.70
FHY35GZ
FH45GZ
15.90
FHY45GZ
1
Air discharge grille
2
Air suction grille
3
Air filter
4
Gas pipe connection
φ
A Flare connection
5
Liquid pipe connection
J
6.35 Flare connection
6
Drain pipe connection V.P.20
7
Grounding terminal M4
8
Suspension bracket
9
Rear piping connection hole - slit hole
10
Upper refrigerant piping connection hole - slit hole
11
Right side piping connection hole - slit hole
12
Rear left side drain piping connection hole - slit hole
13
Left side drain piping connection hole - slit hole
14
Right side drain piping connection hole - slit hole
15
Power supply / control wiring connection (upper)
16
Power supply / control wiring connection (rear)
17
Remote control code connection (upper)
18
Remote control code connection (rear)
19
Rear piping connection hole - slit hole
J
100
Notes:
1. Name plate: sticked on the bottom part of fan housing in suction grille
2. When using a remote controller, this position will be a signal receiver. Refer to the detailed
drawing of the remote controller
3. The standard length of remote control cord is approximately 3m.
(0.5mm x 2 cores x
J
5.4 0.D.)
(Suspension
position)
500
mm
or
more
(Installation
space)
(Installation
space)
Suspension bolt
Service space
60 mm or more
unit (mm)
FHY35
∼
45GZ7V1
Slit hole position for rear piping connection
(from the front)
Drain outlet V.P.20
(for left piping)
DAIKIN name plate
(See note 2)
60 mm or more
Service space
(Installation
space)
Wall hole position for rear
piping connection
(from the front)
3TW20524-1A
(Suspension position)
FH35BZV1
FHYP35
∼
45BV1
View from the front
780
From
the
floor
side
2500
or
more
(Required
space)
Note:
1. Location of unit’s name plate: bottom of fan housing inside the
suction grille.
2. In case of using infrared remote control, this position will be a signal
receiver. Refer to the drawing of infrared remote control in detail.
3. The remote control code is the standard (about 3m outside the
machine) attached.
(0.5 mm
2
x 2 Wicks x O.D.
J
5.4
)
(It is not attached in VRV.)
1
Air discharge grille
2
Air suction grille
3
Air filter
4
Gas pipe connection
J
12.7 flare
5
Liquid pipe connection
J
6.4 flare
6
Drain pipe connection VP20
7
Earth terminal (inside the electric components box) M4
8
Suspension bracket
9
Backward piping and wiring connection opening lid
10
Upward piping and wiring connection opening lid
11
Right side pipe connection - slit hole
12
Left back drain pipe connection - slit hole
13
Right side drain pipe connection - slit hole
14
Right side drain piping connection hole- slit hole
15
Hole of wall for taking out in piping back
J
100
16
Upward drain pipe connection
J
60
17
Upward gas pipe connection
J
36
18
Upward liquid pipe connection
J
26
Position: hole of wall for taking out in piping back
For
height
installation
Floor side
300or
more
Brand name plate
(For left piping)
30 or more
30 or more
(Service space)
(View from the front)
(Hanging position)
Hanging bolt
Position slit hole for taking out in piping back
3D027536A
Drain pipe connection
VP20
Obstacle
(Service space)
(View from the front)
(Hanging
position)
(Required
space)
(Required
space)
(Note 2)
•
Ceiling Suspended Unit
•
R-407C
•
FH(Y)-GZ/BZ/FHYP-B
10
3
9
•
Split - Sky Air
•