5

Wiring diagrams

3D027501-1

FH35

60BZ

1-RED, 2-WHITE, 3-BLACK
33A

Limit switch (swing flap)

A1P

Printed circuit board

A2P

Printed circuit board
(Transformer 220-240V/16V)

C1R

Capacitor (M1F)

F1U

Fuse (250V,5A)

HAP

Light emitting diode (service monitor green)

M1A

Motor (swing flap)

M1F

Motor (indoor fan)

Q1F

Thermo switch (M1F embedded)

R1T

Thermistor (air)

R2T

Thermistor (coil)

RyA

Magnetic relay (M1A)

RyC

Magnetic relay (outdoor unit compressor)

RyP

Magnetic relay (M1P)

SS1

Selector switch (emergency)

X1M

Terminal strip

X2M

Terminal strip

+

Current detect circuit

=

Phase control circuit

Wired remote control

R1T

Thermistor (air)

SS1

Selector switch (main/sub)

Infrared remote control
Receiver / display unit
A3P

Printed circuit board

A4P

Printed circuit board

BS

Push button (on/off)

H1P

Light emitting diode (service monitor red)

H2P

Light emitting diode (service monitor green)

H3P

Light emitting diode (service monitor red)

H4P

Light emitting diode (service monitor orange)

SS1

Selector switch (main/sub)

SS2

Selector switch (wireless address set)

Connector for optional parts
X15A

Connector (float switch)

X25A

Connector (drain pump)

X30A

Connector (interface adaptor for sky air series)

X33A

Connector (adaptor for wiring)

X35A

Connector (group control adaptor)

Switch box

To outdoor

unit

Note) 4

Wired remote

control

Note) 4

Notes

1.

D

: Terminal

F

,

H

: Connector

b

: Protective earth (screw)

2.

B

: Field wiring

3. In case using central remote controller, connect it to the

unit in accordance with the attached instruction manual.

4. X24A is connected when the remote controller kit is

being used.

5. Remote controller model varies according to the

combination system, confirm technical materials and
catalogs, etc. before connecting.

6. In case installing the drain pump, remove the jumper

connector of X15A and execute the additional wiring for
float switch and drain pump.

7. Ground the shield of the remote controller cord to the

indoor unit of the FH-BVE type.

8. Symbols show as follows Red:red, Blk:black, Ylw:yellow,

Org:orange, Gry:gray, Prp:purple, Blu:blue

9. Confirm the method of setting the selector switch (SS1,

SS2) by installation manual and engeneering materials,
etc.

Receiver / display unit

Note) 6

Note) 6

Note) 7

2TW21006-1C

FHY35

45GZ7V1

33S

Limit switch (swing flap)

A1P

Printed circuit board

A2P

Printed circuit board (transformer 220-240V/16V)

C1R

Capacitor (fan)

H1P,H2P Light emitting diode
M1F

Motor

M1S

Motor

Q1F

Thermo switch (M1F embedded)

R1T

Thermistor (air)

R2T

Thermistor (coil)

RyA

Magnetic relay (swing flap)

RyP

Magnetic relay (drain pump)

SS1

Selector switch (emergency)

X1M,X2M Terminal strip
PC

Phase control circuit

RC

Signal receiver

TC

Signal transmission circuit

Connector for optional parts
X15A

Connector (float switch)

X25A

Connector (drain pump)

X30A

Connector (interface adaptor for sky air series)

X33A

Connector (adaptor for wiring)

X35A

Connector (group control adaptor)

Infrared remote control

BS1

On/Off button

BS2

Timer mode start/stop button

BS3,BS8

Programming time button

BS4,BS9

Temperature setting button

BS5

Air flow direction adjust button

BS6

Operation mode selector button

BS7

Timer on/off button

BS11

Fan speed control button

BS12

Inspection/test operation button

BS14

Filter sign reset button

H1P

Light emitting diode (service monitor red)

LCD

Liquid crystal display (LCD)

SS1

Selector switch (main/sub)

Adaptor for wiring
RyC,RyF

Magnetic relay

Outdoor

Wired remote
control

Terminals for operation

indicator

Fan

operation

compressor

operation

Notes

1. Use copper conductors only.
2. When using the central remote control, see

manual for connection to the unit.

3. The remote controller model varies according to

the combination system.

4. When installing the drain pump, remove the

jumper wire of X15A and make the additional
wiring for the float switch and the drain pump.

5. M1S and 33S are only attached to the indoor unit

of the heat pump type

g

Field wiring

D

Terminal

a

: Connector

c

: Wire clamp

b

: Protective earth (screw)

Colours
BLK: Black/ PPL: purple/ BLU: Blue/
WHT: White/ RED: Red/ GRN: green/
GRY: grey/ YLW:Yellow

Indoor

Note 4

Note 5

Details of wired remote control
(optional accessory)

(for heat pump type)

(for cooling only

type)

Adaptor for wiring

Switch box

Simultaneous operation system

Outdoor

unit

Remote control

(master)

(slave)

Ceiling Suspended Unit

R-407C

FH(Y)-GZ/BZ/FHYP-B

10

5

14

Split - Sky Air

Indoor Units

Summary of Contents for FH35GZ

Page 1: ...TECHNICAL DATA Split Sky Air FH Y GZ BZ FHYP B Ceiling Suspended Unit...

Page 2: ...es an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities products and services and to assist in maintaining...

Page 3: ...l drawings 9 4 Piping diagrams 13 5 Wiring diagrams 14 6 Sound level 16 Sound level data Sound pressure spectrum 7 Accessories 19 Standard accessories Optional accessories 8 Control systems 21 9 Safet...

Page 4: ...he outdoor unit can easily be mounted on a roof a terrace or placed against an outside wall For equal distribution in larger rooms up to 3 indoor units can be connected to 1 outdoor They are operated...

Page 5: ...min 13 13 16 medium m3 min low m3 min 10 10 13 Speed steps 2 steps 2 steps 2 steps high rpm low rpm Type Sirocco fan Qty x model 1 x 3D12K1AA1 1 x 3D12K1AA1 1 x 4D12K1AA1 Qty x motor output W 1 x 62 1...

Page 6: ...55 FAN Air flow rate cooling high m3 min 17 24 30 medium m3 min low m3 min 14 20 25 Speed steps 2 steps 2 steps 2 steps high rpm low rpm Type Sirocco fan Qty x model 1 x 4D12K1AA1 1 x 3D12K2AA1 1 x 4D...

Page 7: ...RP100B7V1 W1 T1 RP125B7W1 T1 CURRENT Nominal running current cooling A Maximum running current A For indoor units only FHYP71BV1 FHYP100BV1 FHYP125BV1 POWER SUPPLY V1 V1 V1 NOMINAL DISTRIBUTION SYSTE...

Page 8: ...ating high m3 min 13 13 13 13 16 16 medium m3 min low m3 min 10 10 10 10 13 13 Speed cooling heating steps 2 steps high rpm low rpm Type Sirocco fan Qty x model 1 x 4D12K1AA1 Qty x motor output W 1 x...

Page 9: ...5 58 58 60 60 low dB A 51 51 53 53 55 55 FAN Air flow rate cooling heating high m3 min 17 17 24 24 30 30 medium m3 min low m3 min 14 14 20 20 25 25 Speed cooling heating steps 2 steps 2 steps 2 steps...

Page 10: ...A heating A For indoor units only FHYP71BV1 FHYP100BV1 FHYP125BV1 POWER SUPPLY V1 V1 V1 NOMINAL DISTRIBUTION SYSTEM VOLTAGE Phase 1 1 1 Frequency Hz 50 50 50 Voltage V 220 240 220 240 220 240 NOTES 1...

Page 11: ...ection from the front 3TW20524 1A Suspension position FH35BZV1 FHYP35 45BV1 View from the front 780 From the floor side 2500 or more Required space Note 1 Location of unit s name plate bottom of fan h...

Page 12: ...position Required space Required space Note 2 FH60BZV1 View from the front 780 From the floor side 2500 or more Required space Note 1 Location of unit s name plate bottom of fan housing inside the su...

Page 13: ...g position Required space Required space Note 2 FHYP100BV1 View from the front 780 From the floor side 2500 or more Required space Note 1 Location of unit s name plate bottom of fan housing inside the...

Page 14: ...ion opening lid 10 Upward piping and wiring connection opening lid 11 Right side pipe connection slit hole 12 Left back drain pipe connection slit hole 13 Right side drain pipe connection slit hole 14...

Page 15: ...4 15 9 FHYP60 71BV1 9 5 15 9 FHYP100 125BV1 9 5 19 1 To outdoor unit Indoor unit O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe Heat exchanger Re...

Page 16: ...e selector switch SS1 SS2 by installation manual and engeneering materials etc Receiver display unit Note 6 Note 6 Note 7 2TW21006 1C FHY35 45GZ7V1 33S Limit switch swing flap A1P Printed circuit boar...

Page 17: ...dress set Connector for optional parts X15A Connector float switch X25A Connector drain pump X30A Connector interface adaptor for sky air series X33A Connector adaptor for wiring X35A Connector group...

Page 18: ...pressure level Sound power level H cooling heating 230V Measuring location 50Hz Heat pump H cooling heating L cooling heating FHY35GZ7 38 38 33 33 54 54 FHY45GZ7 39 39 34 34 55 55 FHYP35B 37 37 32 32...

Page 19: ...level Octave band sound pressure level FHY35GZ FHY45GZ Octave band center frequency Hz Octave band center frequency Hz 4D028280 4D028281 4D028282 DU423 489 DU425 4156A approximate threshold hearing f...

Page 20: ...threshold hearing for continuous noise approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise H L H L H L Note 1 Operation sound is measured in an anecho...

Page 21: ...on manual Operation manual Quantity 1 of each 1 pc Shape j 8 For gas pipe j 7 For liquid pipe j 8 Large j 7 Small Remote control cord 1 set Staple x4 flat head screw X4 Drain hose 1 pc Clamp 1 pc Wash...

Page 22: ...Remark FHYP BV1 FH BZV1 35 45 60 71 100 125 Replacement long life filter KAFJ501D56 KAFJ501D80 KAFJ501D112 KAFJ501D160 Drain up kit KDU50B50VE KDU50B71VE KDU50B125VE L type piping kit for upward direc...

Page 23: ...8 Control systems 8 1 Wired remote control BRC1B517 FH Y GZ BRC1B517 Remote control Fig 1 BRC1B517 Ceiling Suspended Unit R 407C FH Y GZ BZ FHYP B 10 8 8 1 21 Split Sky Air Indoor Units...

Page 24: ...This display shows PROGRAMMED TIME of the system start or stop 9 DISPLAY O SET TEMPERATURE This display shows the set temperature 10 DISPLAY B C FAN SPEED The display shows the set fan speed 11 DISPL...

Page 25: ...he desired MODE NO With the E button 3 During group control when setting by each indoor unit push the G button and select the INDOOR UNIT NO To be set This operation is unnecessary when setting by gro...

Page 26: ...V 5A 250V 5A Fan motor thermal fuse C Fan motor thermal protector C OFF 130 5 ON 83 20 OFF 130 5 ON 83 20 OFF 130 5 ON 83 20 OFF 130 5 ON 83 20 OFF 130 5 ON 83 20 OFF 130 5 ON 83 20 3D006611C 10 Insta...

Reviews: