![background image](http://html1.mh-extra.com/html/daikin/fh15cbv1l/fh15cbv1l_technical-manual_4699538023.webp)
21
TM-FLH--0515-C
R20CV1
R25CV1
mm/in
mm/in
mm/in
m
2
/ft
2
0.51 / 5.49
0.61 / 6.58
1
20
cm
3
/ fl.oz.
600 / 20.3
700 / 24.6
V/Ph/Hz
µF
35
45
W
1836
2243
A
8.08
12.13
A
41
56
mm/in
654 / 25.7
756 / 29.8
mm/in
855 / 33.7
mm/in
328 / 12.9
mm/in
693 / 27.3
793 / 31.2
mm/in
990 / 39.0
mm/in
415 / 16.3
kg/lb
43 / 94.8
50 / 110.2
MATERIAL
GALVANIZED STEEL
COLOUR
IVORY WHITE
UNIT
DIMENSION
HEIGHT
WIDTH
DEPTH
PACKING
DIMENSION
DEPTH
UNIT WEIGHT
HEIGHT
WIDTH
MODEL
INDOOR UNIT
FL25EV1L
OUTDOOR UNIT
OUTDOOR UNIT
TUBE
MATERIAL
SEAMLESS INNER GROOVE COPPER
DIAMETER
7.00 / 0.276
THICKNESS
0.23 / 0.009
FIN
MATERIAL
ALUMINUM
THICKNESS
0.11 / 0.004
FACE AREA
ROW
FIN PER INCH
TYPE
ROTARY
OIL TYPE
ATMOS NM56M or SUNISO 4GDID
SUNISO-4GSI/FREOL-K56
OIL AMOUNT
INSULATION GRADE
E
POWER SOURCE
220-240 / 1 / 50
CAPACITOR
RATED INPUT POWER
RATED RUNNING CURRENT
LOCKED ROTOR AMP.
l/s / CFM
614 / 1300
755 / 1600
AIR FLOW
dBA
51
52
SOUND PRESSURE LEVEL
mm/in
6.35 / 1/4
9.52 / 3/8
mm/in
PIPE
CONNECTION
FAN
FAN MOTOR
COMPRESSOR
COIL
CASING
TYPE
FLARE
SIZE
15.88 / 5/8
LIQUID
GAS
mm/in
MATERIAL
ASG 20
QUANTITY
1
DRIVE
DIRECT
DIAMETER
455 / 17.9
TYPE
PROPELLER
V/Ph/Hz
W
120
132
A
0.53
0.58
W
RPM
32
680
60
840
TYPE
INDUCTION
QUANTITY
1
INDEX OF PROTECTION (IP)
IP23
INSULATION GRADE
F
POWER SOURCE
220-240 / 1 / 50
RATED INPUT POWER
RATED RUNNING CURRENT
MOTOR OUTPUT
MOTOR SPEED
POLES
6
Specification (R-22)
Ceiling Convertible Type - FL-E Series (CONT’D)
1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240.
3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW:
COOLING - 27˚C DB / 19˚C WB INDOOR AND 35˚C DB / 24˚C WB OUTDOOR
4) SOUND PRESSURE LEVELS ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION,
THE RESULT WILL BE HIGHER AS A RESULT OF AMBIENT CONDITION.
5) THE CURRENT MEASURED AT SITE MAY VARY FROM THE SPECIFICATION STATED.
Summary of Contents for FH15CBV1L
Page 1: ...Ceiling Exposed TM FLH 0515 C TECHNICAL MANUAL...
Page 54: ...52 TM FLH 0515 C Figure 2 Figure 3...
Page 55: ...53 TM FLH 0515 C Figure 4 Figure 5...
Page 69: ...67 TM FLH 0515 C Outdoor Unit Model R18 20CV1 Indoor Unit Model FH20CBV1L FH20CBV1M...
Page 72: ...70 TM FLH 0515 C Indoor Unit Model FLN30EV1L FLN30EV1M Outdoor Unit Model RN28CV1...
Page 73: ...71 TM FLH 0515 C Outdoor Unit Model R35DV1 Indoor Unit Model FH40CBV1L FH40CBV1M...
Page 74: ...72 TM FLH 0515 C Indoor Unit Model FLN40DV1L FLN40DV1M Outdoor Unit Model RN35DV1...
Page 75: ...73 TM FLH 0515 C Model R40 50DY1 Model FH40 50CBV1L FH40 50CBV1M...
Page 76: ...74 TM FLH 0515 C Model RN40 50DY1 Model FLN40 50DV1L FLN40 50DV1M...
Page 77: ...75 TM FLH 0515 C Model R61DY1 Model FH61CBV1L FH61CBV1M...
Page 78: ...76 TM FLH 0515 C Model RN61DY1 Model FHN62CV1L FHN62CV1M...
Page 86: ...84 TM FLH 0515 C FL15 20 25EV1L FLN15 20 25 30EV1L Note Dimension in mm...