7 “ON TIMER” and “OFF TIMER”
The unit has 2-event timer, namely Timer 1 and Timer 2, each event has an ON TIMER and an OFF
TIMER. The key press activity for Timer ON and Timer OFF is shown on Table 1.1
Table 1.1: Timer ON and Timer OFF key press and event sequence.
All timers are event-triggered timers and can be overridden by the ON/OFF button and Override function.
Set Event 1 and Event 2 Timers
Process for Timer ON and Timer OFF is the same.
1. Press and hold Timer ON/OFF key for 3 seconds to go into timer setting mode. (Icon ON 1 or
OFF 1 will blink)
2. Press UP or DOWN to select Timer 1 or Timer 2 to set. (‘1’ blinking indicate that Timer 1 is
currently selected, ‘2’ blinking indicate that Timer 2 is currently selected)
3. Press Timer ON/OFF key again to confirm. (Day will blink next)
4. Press UP or DOWN to select the day.
5. Press Timer ON/OFF key again to confirm the day. (Hour will blink next)
4. Press UP or DOWN to change the hour.
5. Press Timer ON/OFF key again to confirm the hour. (Minute will blink next)
6. Press UP or DOWN to change the minute.
7. Press Timer ON/OFF key again to confirm the minute.
Each timer (Timer 1 ON or Timer 1 OFF or Timer 2 ON or Timer 2 OFF) will only be set separately
after all 7 steps, if there is no key operation for 5 seconds during setting the timer, it will
automatically exits from setting mode and no changes will be made.
ON/OFF timer will be checked every 1 minute.
It is not advisable to set ON TIMER and OFF TIMER to have same values. Shall these occur, the
effective timer will be treated with priority as stated in Table 1.2.
Example:
ON TMR 2 settings: DAY – TUE, TIMER – 5.00pm
OFF TMR 1 settings: DAY – TUE, TIMER – 5.00pm
Outcome when RTC reaches 5.00pm on TUE:
- when unit is on, no respond.
- when unit is off, unit will trigger to on.
Table 1.2: Timer Priority
ON Timer 1
ON Timer 2
OFF Timer 1
OFF Timer 2
Deactivated
Deactivated
Deactivated
Deactivated
Activated
Deactivated
Activated
Deactivated
Deactivated
Activated
Deactivated
Activated
Activated
Activated
Activated
Activated
TIMER ON KEY
TIMER OFF KEY
Priority
Timer
1 (Highest)
2
3
4 (Lowest)
ONTMR2
OFFTMR2
ONTMR1
OFFTMR1
Upon IR reception, IR wireless remote controller will override ON TIMER 2 and OFF TIMER 2 settings.
Summary of Contents for FH15CBV1L
Page 1: ...Ceiling Exposed TM FLH 0515 C TECHNICAL MANUAL...
Page 54: ...52 TM FLH 0515 C Figure 2 Figure 3...
Page 55: ...53 TM FLH 0515 C Figure 4 Figure 5...
Page 69: ...67 TM FLH 0515 C Outdoor Unit Model R18 20CV1 Indoor Unit Model FH20CBV1L FH20CBV1M...
Page 72: ...70 TM FLH 0515 C Indoor Unit Model FLN30EV1L FLN30EV1M Outdoor Unit Model RN28CV1...
Page 73: ...71 TM FLH 0515 C Outdoor Unit Model R35DV1 Indoor Unit Model FH40CBV1L FH40CBV1M...
Page 74: ...72 TM FLH 0515 C Indoor Unit Model FLN40DV1L FLN40DV1M Outdoor Unit Model RN35DV1...
Page 75: ...73 TM FLH 0515 C Model R40 50DY1 Model FH40 50CBV1L FH40 50CBV1M...
Page 76: ...74 TM FLH 0515 C Model RN40 50DY1 Model FLN40 50DV1L FLN40 50DV1M...
Page 77: ...75 TM FLH 0515 C Model R61DY1 Model FH61CBV1L FH61CBV1M...
Page 78: ...76 TM FLH 0515 C Model RN61DY1 Model FHN62CV1L FHN62CV1M...
Page 86: ...84 TM FLH 0515 C FL15 20 25EV1L FLN15 20 25 30EV1L Note Dimension in mm...